BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

948 related articles for article (PubMed ID: 30274614)

  • 1. Transcatheter Aortic Valve Replacement for Bicuspid Aortic Valve: Challenges and Pitfalls.
    Yoon SH; Makkar R
    Interv Cardiol Clin; 2018 Oct; 7(4):477-488. PubMed ID: 30274614
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Transcatheter aortic valve replacement in bicuspid aortic valve stenosis: where do we stand?
    Yoon SH; Sharma R; Chakravarty T; Miyasaka M; Ochiai T; Nomura T; Gellada N; Nemanpour S; Nakamura M; Chen W; Makkar R
    J Cardiovasc Surg (Torino); 2018 Jun; 59(3):381-391. PubMed ID: 29332374
    [TBL] [Abstract][Full Text] [Related]  

  • 3. TAVI in Bicuspid Aortic Valves 'Made Easy'.
    Frangieh AH; Kasel AM
    Eur Heart J; 2017 Apr; 38(16):1177-1181. PubMed ID: 28934845
    [No Abstract]   [Full Text] [Related]  

  • 4. Successful transcatheter aortic valve replacement for bicuspid aortic valve.
    Maeda K; Kuratani T; Torikai K; Shimamura K; Ueno T; Toda K; Sawa Y
    Ann Thorac Cardiovasc Surg; 2014; 20 Suppl():705-8. PubMed ID: 23995345
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transcatheter aortic valve implantation in bicuspid aortic valve stenosis.
    Perlman GY; Blanke P; Webb JG
    EuroIntervention; 2016 Sep; 12(Y):Y42-5. PubMed ID: 27640030
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Supra-annular structure assessment for self-expanding transcatheter heart valve size selection in patients with bicuspid aortic valve.
    Liu X; He Y; Zhu Q; Gao F; He W; Yu L; Zhou Q; Kong M; Wang J
    Catheter Cardiovasc Interv; 2018 Apr; 91(5):986-994. PubMed ID: 29399947
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Temporal Trends and Outcomes of Transcatheter Versus Surgical Aortic Valve Replacement for Bicuspid Aortic Valve Stenosis.
    Elbadawi A; Saad M; Elgendy IY; Barssoum K; Omer MA; Soliman A; Almahmoud MF; Ogunbayo GO; Mentias A; Gilani S; Jneid H; Aronow HD; Kleiman N; Abbott JD
    JACC Cardiovasc Interv; 2019 Sep; 12(18):1811-1822. PubMed ID: 31537280
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Transcatheter Aortic Valve Replacement in Patients with Aortic Stenosis Having Coronary Cusp Fusion versus Mixed Cusp Fusion Nonraphe Bicuspid Aortic Valve.
    Lei WH; Liao YB; Wang ZJ; Ou YW; Tsauo JY; Li YJ; Xiong TY; Zhao ZG; Wei X; Meng W; Feng Y; Chen M
    J Interv Cardiol; 2019; 2019():7348964. PubMed ID: 31777470
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Transcatheter aortic valve replacement for stenotic bicuspid aortic valves: Systematic review and meta analyses of observational studies.
    Reddy G; Wang Z; Nishimura RA; Greason KL; Yoon SH; Makkar RR; Holmes DR
    Catheter Cardiovasc Interv; 2018 Apr; 91(5):975-983. PubMed ID: 28963771
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Successful transcatheter aortic valve replacement in an oversized 800 mm
    Buchanan KD; Rogers T; Shults C; Ben-Dor I; Satler LF; Waksman R
    Cardiovasc Revasc Med; 2018 Dec; 19(8S):65-67. PubMed ID: 29716809
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Bicuspid aortic valve: any room for TAVR?
    Colombo A; Latib A
    J Am Coll Cardiol; 2014 Dec; 64(22):2340-2. PubMed ID: 25465420
    [No Abstract]   [Full Text] [Related]  

  • 12. Editorial: The puzzle of TAVR in bicuspid aortic valves: One piece at a time.
    Lahoud RN; Krishnan AM
    Cardiovasc Revasc Med; 2024 Jun; 63():21-22. PubMed ID: 38378378
    [No Abstract]   [Full Text] [Related]  

  • 13. Transcatheter Aortic Valve Replacement in Bicuspid Aortic Stenosis Using Lotus Valve System.
    Chan AW; Wong D; Charania J
    Catheter Cardiovasc Interv; 2017 Jul; 90(1):157-163. PubMed ID: 27029503
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Optimal pre-TAVR annulus sizing in patients with bicuspid aortic valve: area-derived perimeter by CT is the best-correlated measure with intraoperative sizing.
    Wang Y; Wang M; Song G; Wang W; Lv B; Wang H; Wu Y
    Eur Radiol; 2019 Jan; 29(1):259-269. PubMed ID: 29926206
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Bicuspid aortic stenosis in transcatheter aortic valve replacement era: Emerging confusions hindering the standardization of the procedure.
    Xiong TY; Zhao ZG; Chen M
    Cardiol J; 2018; 25(4):542-544. PubMed ID: 30211936
    [No Abstract]   [Full Text] [Related]  

  • 16. Transcatheter Aortic Valve Replacement in Low-Risk Patients With Symptomatic Severe Bicuspid Aortic Valve Stenosis.
    Waksman R; Craig PE; Torguson R; Asch FM; Weissman G; Ruiz D; Gordon P; Ehsan A; Parikh P; Bilfinger T; Levitt R; Hahn C; Roberts D; Ingram M; Hanna N; Comas G; Zhang C; Ben-Dor I; Satler LF; Garcia-Garcia HM; Shults C; Rogers T
    JACC Cardiovasc Interv; 2020 May; 13(9):1019-1027. PubMed ID: 32381181
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [TAVR and bicuspid aortic valve].
    Hovasse T; Tchétché D
    Ann Cardiol Angeiol (Paris); 2019 Dec; 68(6):450-452. PubMed ID: 31718785
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Annular versus supra-annular sizing for transcatheter aortic valve replacement in bicuspid aortic valve disease.
    Weir-McCall JR; Attinger-Toller A; Blanke P; Perlman GY; Sellers SL; Wood D; Webb JG; Leipsic J
    J Cardiovasc Comput Tomogr; 2020; 14(5):407-413. PubMed ID: 32029384
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Less pronounced reverse left ventricular remodeling in patients with bicuspid aortic stenosis treated with transcatheter aortic valve replacement compared to tricuspid aortic stenosis.
    Xiong TY; Wang X; Li YJ; Liao YB; Zhao ZG; Wei X; Xu YN; Zheng MX; Zhou X; Peng Y; Wei JF; Feng Y; Chen M
    Int J Cardiovasc Imaging; 2018 Nov; 34(11):1761-1767. PubMed ID: 29915878
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The first case of "locked-in leaflet" after transcatheter aortic valve replacement in a patient with bicuspid aortic stenosis.
    Shibata N; Matsumoto K; Toba T; Mori S; Shimoyama S; Tanaka H; Shinke T; Hirata KI
    Echocardiography; 2018 Jan; 35(1):110-113. PubMed ID: 29151260
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 48.