These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

233 related articles for article (PubMed ID: 30276460)

  • 1. Smooth Muscle Alpha Actin Immunoexpression (α-Sma) and CD-117 Antibody (C-Kit) in Capsules Formed by Polyurethane Foam-Coated Silicone Implants and with Textured Surface: A Study on Rats.
    Silva EN; Ribas-Filho JM; Tabushi FI; Silva MAP; Siqueira EBD; de Noronha L; da Silva ABD; Lipinski LC; Guth I; Vosgerau LM
    Aesthetic Plast Surg; 2019 Feb; 43(1):233-242. PubMed ID: 30276460
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The In Vivo Pericapsular Tissue Response to Modern Polyurethane Breast Implants.
    Frame J; Kamel D; Olivan M; Cintra H
    Aesthetic Plast Surg; 2015 Oct; 39(5):713-23. PubMed ID: 26304599
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Histological evaluation of capsules formed by silicon implants coated with polyurethane foam and with a textured surface in rats.
    Silva EN; Ribas-Filho JM; Czeczko NG; Pachnicki JP; Netto MR; Lipinski LC; Noronha L; Colman J; Zeni JO; Carvalho CA
    Acta Cir Bras; 2016 Dec; 31(12):774-782. PubMed ID: 28076500
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Breast Implant Capsule: A Murine Model Comparing Capsular Contracture Susceptibility Among Six Breast Implants Available in the Market.
    Bérniz C; Carmona-Torre F; Gómez-Martínez C; Fernéndez-Ciriza L; Del Pozo JL; Hontanilla B
    Aesthetic Plast Surg; 2023 Oct; 47(5):2093-2105. PubMed ID: 37022396
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Vascular endothelial growth factor overexpression positively modulates the characteristics of periprosthetic tissue of polyurethane-coated silicone breast implant in rats.
    Vieira VJ; d'Acampora AJ; Marcos ABW; Di Giunta G; de Vasconcellos ZAA; Bins-Ely J; d'Eça Neves R; Figueiredo CP
    Plast Reconstr Surg; 2010 Dec; 126(6):1899-1910. PubMed ID: 21124130
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Long-Term Effects of the Collagenase of the Bacterium Clostridium histolyticum for the Treatment of Capsular Fibrosis After Silicone Implants.
    Fischer S; Diehm Y; Henzler T; Berger MR; Kolbenschlag J; Latz A; Bueno EM; Hirche C; Kneser U; Pomahac B
    Aesthetic Plast Surg; 2017 Feb; 41(1):211-220. PubMed ID: 28008464
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Silicone Implants with Smooth Surfaces Induce Thinner but Denser Fibrotic Capsules Compared to Those with Textured Surfaces in a Rodent Model.
    Fischer S; Hirche C; Reichenberger MA; Kiefer J; Diehm Y; Mukundan S; Alhefzi M; Bueno EM; Kneser U; Pomahac B
    PLoS One; 2015; 10(7):e0132131. PubMed ID: 26151888
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effect of a bacterial contamination on the formation of capsular contracture with polyurethane breast implants in comparison with textured silicone implants: an animal study.
    Bergmann PA; Tamouridis G; Lohmeyer JA; Mauss KL; Becker B; Knobloch J; Mailänder P; Siemers F
    J Plast Reconstr Aesthet Surg; 2014 Oct; 67(10):1364-70. PubMed ID: 24953446
    [TBL] [Abstract][Full Text] [Related]  

  • 9. In Vivo and In Vitro Fibroblasts' Behavior and Capsular Formation in Correlation with Smooth and Textured Silicone Surfaces.
    Huang SQ; Chen Y; Zhu Q; Zhang YM; Lei ZY; Zhou X; Fan DL
    Aesthetic Plast Surg; 2022 Jun; 46(3):1164-1177. PubMed ID: 35237878
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effects of Different Concentrations of Injectable Collagenase Enzyme on Capsular Tissue Around Silicone Implants: A Preliminary Experimental Study for the Development of a New Treatment Strategy.
    Yeşiloğlu N; Temiz G; Sarıcı M; Yıldız K; Şirinoğlu H; Güvercin E; Akpınar AC; Filinte GT; Filinte D
    Aesthetic Plast Surg; 2016 Feb; 40(1):164-73. PubMed ID: 26715576
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effects of Medical Chitosan on Capsular Formation Following Silicone Implant Insertion in a Rabbit Model.
    Li S; Ren L; Xu H; Jia D; Luo S; Hao L; Yang D
    Aesthetic Plast Surg; 2016 Aug; 40(4):613-24. PubMed ID: 27302415
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Histological characterization of human breast implant capsules.
    Bui JM; Perry T; Ren CD; Nofrey B; Teitelbaum S; Van Epps DE
    Aesthetic Plast Surg; 2015 Jun; 39(3):306-15. PubMed ID: 25743110
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Prevention of capsular contracture with Guardix-SG(®) after silicone implant insertion.
    Park SO; Han J; Minn KW; Jin US
    Aesthetic Plast Surg; 2013 Jun; 37(3):543-8. PubMed ID: 23456146
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Management of Capsular Contracture in Cases of Silicone Gel Breast Implant Rupture with Use of Pulse Lavage and Open Capsulotomy.
    Lam MC; Walgenbach-Brünagel G; Pryalukhin A; Vorhold J; Pech T; Kalff JC; Kristiansen G; Walgenbach KJ
    Aesthetic Plast Surg; 2019 Oct; 43(5):1173-1185. PubMed ID: 31367775
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Does Implant Surface Texture Affect the Risk of Capsular Contracture in Subglandular Breast Augmentation and Breast Augmentation-Mastopexy?
    Lista F; Austin RE; Saheb-Al-Zamani M; Ahmad J
    Aesthet Surg J; 2020 Apr; 40(5):499-512. PubMed ID: 31529039
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A simple method to inset and position polyurethane-covered breast implants.
    Castello MF; Han S; Silvestri A; Grassetti L; Torresetti M; Zhang YX; Perdanasari AT; Marcelli C; Gigliotti D; Lazzeri D
    Aesthetic Plast Surg; 2014 Apr; 38(2):365-8. PubMed ID: 24610108
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The Histological Composition of Capsular Contracture Focussed on the Inner Layer of the Capsule: An Intra-Donor Baker-I Versus Baker-IV Comparison.
    de Bakker E; van den Broek LJ; Ritt MJPF; Gibbs S; Niessen FB
    Aesthetic Plast Surg; 2018 Dec; 42(6):1485-1491. PubMed ID: 30187083
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Reduced Remodeling Biomarkers Tissue Expression in Nanotextured Compared With Polyurethane Implants Capsules: A Study in Rats.
    Pontes GH; Carneiro Filho FSM; Vargas Guerrero LA; Lipinski LC; de Noronha L; Silva EN; Serra-Guimarães F
    Aesthet Surg J; 2021 May; 41(6):NP664-NP683. PubMed ID: 33232440
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The capsule quality of saline-filled smooth silicone, textured silicone, and polyurethane implants in rabbits: a long-term study.
    Bucky LP; Ehrlich HP; Sohoni S; May JW
    Plast Reconstr Surg; 1994 May; 93(6):1123-31; discussion 1132-3. PubMed ID: 8171130
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Silicone Breast Implant Injector: A Retooled Breast Augmentation Device.
    Tsao SB; Wu CC
    Aesthetic Plast Surg; 2021 Feb; 45(1):95-99. PubMed ID: 32978659
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.