447 related articles for article (PubMed ID: 30279741)
1. MRI and histological evaluation of pulsed focused ultrasound and microbubbles treatment effects in the brain.
Kovacs ZI; Tu TW; Sundby M; Qureshi F; Lewis BK; Jikaria N; Burks SR; Frank JA
Theranostics; 2018; 8(17):4837-4855. PubMed ID: 30279741
[TBL] [Abstract][Full Text] [Related]
2. In vivo imaging of sterile microglial activation in rat brain after disrupting the blood-brain barrier with pulsed focused ultrasound: [18F]DPA-714 PET study.
Sinharay S; Tu TW; Kovacs ZI; Schreiber-Stainthorp W; Sundby M; Zhang X; Papadakis GZ; Reid WC; Frank JA; Hammoud DA
J Neuroinflammation; 2019 Jul; 16(1):155. PubMed ID: 31345243
[TBL] [Abstract][Full Text] [Related]
3. Diffusion Tensor Imaging and Chemical Exchange Saturation Transfer MRI Evaluation on the Long-Term Effects of Pulsed Focused Ultrasound and Microbubbles Blood Brain Barrier Opening in the Rat.
Tu TW; Kovacs ZI; Sundby M; Witko JA; Papadakis GZ; Reid WC; Hammoud DA; Frank JA
Front Neurosci; 2020; 14():908. PubMed ID: 32982680
[TBL] [Abstract][Full Text] [Related]
4. Disrupting the blood-brain barrier by focused ultrasound induces sterile inflammation.
Kovacs ZI; Kim S; Jikaria N; Qureshi F; Milo B; Lewis BK; Bresler M; Burks SR; Frank JA
Proc Natl Acad Sci U S A; 2017 Jan; 114(1):E75-E84. PubMed ID: 27994152
[TBL] [Abstract][Full Text] [Related]
5. Targeted Blood Brain Barrier Opening With Focused Ultrasound Induces Focal Macrophage/Microglial Activation in Experimental Autoimmune Encephalomyelitis.
Schregel K; Baufeld C; Palotai M; Meroni R; Fiorina P; Wuerfel J; Sinkus R; Zhang YZ; McDannold N; White PJ; Guttmann CRG
Front Neurosci; 2021; 15():665722. PubMed ID: 34054415
[TBL] [Abstract][Full Text] [Related]
6. Molecular and histological effects of MR-guided pulsed focused ultrasound to the rat heart.
Jang KW; Tu TW; Nagle ME; Lewis BK; Burks SR; Frank JA
J Transl Med; 2017 Dec; 15(1):252. PubMed ID: 29237455
[TBL] [Abstract][Full Text] [Related]
7. Multiple sessions of liposomal doxorubicin delivery via focused ultrasound mediated blood-brain barrier disruption: a safety study.
Aryal M; Vykhodtseva N; Zhang YZ; McDannold N
J Control Release; 2015 Apr; 204():60-9. PubMed ID: 25724272
[TBL] [Abstract][Full Text] [Related]
8. MRI-guided targeted blood-brain barrier disruption with focused ultrasound: histological findings in rabbits.
McDannold N; Vykhodtseva N; Raymond S; Jolesz FA; Hynynen K
Ultrasound Med Biol; 2005 Nov; 31(11):1527-37. PubMed ID: 16286030
[TBL] [Abstract][Full Text] [Related]
9. Efficiency of drug delivery enhanced by acoustic pressure during blood-brain barrier disruption induced by focused ultrasound.
Yang FY; Lee PY
Int J Nanomedicine; 2012; 7():2573-82. PubMed ID: 22679368
[TBL] [Abstract][Full Text] [Related]
10. Neutrophil recruitment and leukocyte response following focused ultrasound and microbubble mediated blood-brain barrier treatments.
Poon C; Pellow C; Hynynen K
Theranostics; 2021; 11(4):1655-1671. PubMed ID: 33408773
[No Abstract] [Full Text] [Related]
11. Investigating the effects of dexamethasone on blood-brain barrier permeability and inflammatory response following focused ultrasound and microbubble exposure.
McMahon D; Oakden W; Hynynen K
Theranostics; 2020; 10(4):1604-1618. PubMed ID: 32042325
[No Abstract] [Full Text] [Related]
12. Intracranial inertial cavitation threshold and thermal ablation lesion creation using MRI-guided 220-kHz focused ultrasound surgery: preclinical investigation.
Xu Z; Carlson C; Snell J; Eames M; Hananel A; Lopes MB; Raghavan P; Lee CC; Yen CP; Schlesinger D; Kassell NF; Aubry JF; Sheehan J
J Neurosurg; 2015 Jan; 122(1):152-61. PubMed ID: 25380106
[TBL] [Abstract][Full Text] [Related]
13. Histologic evaluation of activation of acute inflammatory response in a mouse model following ultrasound-mediated blood-brain barrier using different acoustic pressures and microbubble doses.
Pascal A; Li N; Lechtenberg KJ; Rosenberg J; Airan RD; James ML; Bouley DM; Pauly KB
Nanotheranostics; 2020; 4(4):210-223. PubMed ID: 32802731
[No Abstract] [Full Text] [Related]
14. Targeted and reversible blood-retinal barrier disruption via focused ultrasound and microbubbles.
Park J; Zhang Y; Vykhodtseva N; Akula JD; McDannold NJ
PLoS One; 2012; 7(8):e42754. PubMed ID: 22912733
[TBL] [Abstract][Full Text] [Related]
15. MR-guided pulsed focused ultrasound improves mesenchymal stromal cell homing to the myocardium.
Jang KW; Tu TW; Rosenblatt RB; Burks SR; Frank JA
J Cell Mol Med; 2020 Nov; 24(22):13278-13288. PubMed ID: 33067927
[TBL] [Abstract][Full Text] [Related]
16. An advanced focused ultrasound protocol improves the blood-brain barrier permeability and doxorubicin delivery into the rat brain.
Jung B; Huh H; Lee EH; Han M; Park J
J Control Release; 2019 Dec; 315():55-64. PubMed ID: 31669208
[TBL] [Abstract][Full Text] [Related]
17. The new insight into the inflammatory response following focused ultrasound-mediated blood-brain barrier disruption.
Choi HJ; Han M; Seo H; Park CY; Lee EH; Park J
Fluids Barriers CNS; 2022 Dec; 19(1):103. PubMed ID: 36564820
[TBL] [Abstract][Full Text] [Related]
18. Neuron labeling with rhodamine-conjugated Gd-based MRI contrast agents delivered to the brain via focused ultrasound.
Morse SV; Boltersdorf T; Harriss BI; Chan TG; Baxan N; Jung HS; Pouliopoulos AN; Choi JJ; Long NJ
Theranostics; 2020; 10(6):2659-2674. PubMed ID: 32194827
[TBL] [Abstract][Full Text] [Related]
19. Acute Inflammatory Response Following Increased Blood-Brain Barrier Permeability Induced by Focused Ultrasound is Dependent on Microbubble Dose.
McMahon D; Hynynen K
Theranostics; 2017; 7(16):3989-4000. PubMed ID: 29109793
[No Abstract] [Full Text] [Related]
20. Quantitative study of focused ultrasound enhanced doxorubicin delivery to prostate tumor in vivo with MRI guidance.
Chen X; Cvetkovic D; Ma CM; Chen L
Med Phys; 2012 May; 39(5):2780-6. PubMed ID: 22559650
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]