These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

169 related articles for article (PubMed ID: 30282507)

  • 1. A microcomputed tomography evaluation of the shaping ability of three thermally-treated nickel-titanium rotary file systems in curved canals.
    Huang Z; Quan J; Liu J; Zhang W; Zhang X; Hu X
    J Int Med Res; 2019 Jan; 47(1):325-334. PubMed ID: 30282507
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Shaping ability of BioRace, ProTaper NEXT and Genius nickel-titanium instruments in curved canals of mandibular molars: a MicroCT study.
    Drukteinis S; Peciuliene V; Dummer PMH; Hupp J
    Int Endod J; 2019 Jan; 52(1):86-93. PubMed ID: 29858500
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of centring ability and transportation between four nickel titanium instrumentation techniques by micro-computed tomography.
    Saberi N; Patel S; Mannocci F
    Int Endod J; 2017 Jun; 50(6):595-603. PubMed ID: 27159500
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Root canal preparation of mandibular molars with 3 nickel-titanium rotary instruments: a micro-computed tomographic study.
    Zhao D; Shen Y; Peng B; Haapasalo M
    J Endod; 2014 Nov; 40(11):1860-4. PubMed ID: 25205262
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Root Canal Surface Strain and Canal Center Transportation Induced by 3 Different Nickel-Titanium Rotary Instrument Systems.
    Liu W; Wu B
    J Endod; 2016 Feb; 42(2):299-303. PubMed ID: 26686822
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Root Canal Preparation and Enlargement Using Thermally Treated Nickel-Titanium Rotary Systems in Curved Canals.
    Pivoto-João MMB; Tanomaru-Filho M; Pinto JC; Espir CG; Guerreiro-Tanomaru JM
    J Endod; 2020 Nov; 46(11):1758-1765. PubMed ID: 32818566
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A Micro-computed Tomography Evaluation of the Shaping Ability of Two Nickel-titanium Instruments, HyFlex EDM and ProTaper Next.
    Venino PM; Citterio CL; Pellegatta A; Ciccarelli M; Maddalone M
    J Endod; 2017 Apr; 43(4):628-632. PubMed ID: 28215346
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Efficacy of ProTaper NEXT Compared with Reciproc in Removing Obturation Material from Severely Curved Root Canals: A Micro-Computed Tomography Study.
    Nevares G; de Albuquerque DS; Freire LG; Romeiro K; Fogel HM; Dos Santos M; Cunha RS
    J Endod; 2016 May; 42(5):803-8. PubMed ID: 27117757
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Micro-Computed Tomography Evaluation of ProTaper Next and BioRace Shaping Outcomes in Maxillary First Molar Curved Canals.
    Pasqualini D; Alovisi M; Cemenasco A; Mancini L; Paolino DS; Bianchi CC; Roggia A; Scotti N; Berutti E
    J Endod; 2015 Oct; 41(10):1706-10. PubMed ID: 26321061
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of root canal transportation, centering ratio, and remaining dentin thickness of TRUShape and ProTaper Next systems in curved root canals using micro-computed tomography.
    Elnaghy AM; Al-Dharrab AA; Abbas HM; Elsaka SE
    Quintessence Int; 2017; 48(1):27-32. PubMed ID: 27669727
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Micro-Computed Tomographic Evaluation of 2 Nickel-Titanium Instrument Systems in Shaping Root Canals.
    da Silva Limoeiro AG; Dos Santos AH; De Martin AS; Kato AS; Fontana CE; Gavini G; Freire LG; da Silveira Bueno CE
    J Endod; 2016 Mar; 42(3):496-9. PubMed ID: 26776939
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Shaping ability of ProTaper Universal, WaveOne and ProTaper Next in simulated L-shaped and S-shaped root canals.
    Wu H; Peng C; Bai Y; Hu X; Wang L; Li C
    BMC Oral Health; 2015 Mar; 15():27. PubMed ID: 25886847
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of the Shaping Characteristics of ProTaper Gold, ProTaper NEXT, and ProTaper Universal in Curved Canals.
    Gagliardi J; Versiani MA; de Sousa-Neto MD; Plazas-Garzon A; Basrani B
    J Endod; 2015 Oct; 41(10):1718-24. PubMed ID: 26321062
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Shaping Ability of HyFlex EDM and ProTaper Next Rotary Instruments in Curved Root Canals: A Micro-CT Study.
    Turkistani AK; Gomaa MM; Shafei LA; Alsofi L; Majeed A; AlShwaimi E
    J Contemp Dent Pract; 2019 Jun; 20(6):680-685. PubMed ID: 31358709
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of apical transportation and centring ability of five thermally treated NiTi rotary systems.
    Pinheiro SR; Alcalde MP; Vivacqua-Gomes N; Bramante CM; Vivan RR; Duarte MAH; Vasconcelos BC
    Int Endod J; 2018 Jun; 51(6):705-713. PubMed ID: 29178173
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Shaping Ability of ProTaper Universal, ProTaper NEXT and WaveOne Primary in Severely Curved Resin Blocks.
    Tavanafar S; Gilani PV; Saleh AM; Schäfer E
    J Contemp Dent Pract; 2019 Mar; 20(3):363-369. PubMed ID: 31204330
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Shaping Ability of ProTaper Next, WaveOne, and Reciproc in Simulated Root Canals.
    Maia Filho EM; Dos Reis Santos RM; Lima DM; da Silva Pereira SM; Soares JA; de Jesus Tavarez RR; Ferreira MC; Carvalho CN; Bandeca MC; Tonetto MR; Borges AH; de Castro Rizzi C
    J Contemp Dent Pract; 2016 Nov; 17(11):902-906. PubMed ID: 27965498
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Root Canal Shaping Using Nickel Titanium, M-Wire, and Gold Wire: A Micro-computed Tomographic Comparative Study of One Shape, ProTaper Next, and WaveOne Gold Instruments in Maxillary First Molars.
    van der Vyver PJ; Paleker F; Vorster M; de Wet FA
    J Endod; 2019 Jan; 45(1):62-67. PubMed ID: 30446405
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparative evaluation of the shaping ability of two different nickel-titanium rotary files in curved root canals of extracted human molar teeth.
    Ferrara G; Taschieri S; Corbella S; Ceci C; Del Fabbro M; Machtou P
    J Investig Clin Dent; 2017 Feb; 8(1):. PubMed ID: 26343421
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Rotary nickel-titanium GT and ProTaper files for root canal shaping by novice operators: a radiographic and micro-computed tomography evaluation.
    Gekelman D; Ramamurthy R; Mirfarsi S; Paqué F; Peters OA
    J Endod; 2009 Nov; 35(11):1584-8. PubMed ID: 19840653
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.