144 related articles for article (PubMed ID: 30283199)
1. A New Scatter Particle and Mixture Fluid for Preparing Blood Mimicking Fluid for Wall-Less Flow Phantom.
Oglat AA; Matjafri MZ; Suardi N; Abdelrahman MA; Oqlat MA; Oqlat AA
J Med Ultrasound; 2018; 26(3):134-142. PubMed ID: 30283199
[TBL] [Abstract][Full Text] [Related]
2. A blood-mimicking fluid with cholesterol as scatter particles for wall-less carotid artery phantom applications.
Dakok KK; Matjafri MZ; Suardi N; Oglat AA; Nabasu SE
J Ultrason; 2021 Aug; 21(86):e219-e224. PubMed ID: 34540276
[No Abstract] [Full Text] [Related]
3. Validation of a new blood-mimicking fluid for use in Doppler flow test objects.
Ramnarine KV; Nassiri DK; Hoskins PR; Lubbers J
Ultrasound Med Biol; 1998 Mar; 24(3):451-9. PubMed ID: 9587999
[TBL] [Abstract][Full Text] [Related]
4. A Review of Suspension-Scattered Particles Used in Blood-Mimicking Fluid for Doppler Ultrasound Imaging.
Oglat AA; Suardi N; Matjafri MZ; Oqlat MA; Abdelrahman MA; Oqlat AA
J Med Ultrasound; 2018; 26(2):68-76. PubMed ID: 30065522
[TBL] [Abstract][Full Text] [Related]
5. Development of an example flow test object and comparison of five of these test objects, constructed in various laboratories.
Teirlinck CJ; Bezemer RA; Kollmann C; Lubbers J; Hoskins PR; Ramnarine KV; Fish P; Fredeldt KE; Schaarschmidt UG
Ultrasonics; 1998 Feb; 36(1-5):653-60. PubMed ID: 9651595
[TBL] [Abstract][Full Text] [Related]
6. Erratum: Preparation of Poly(pentafluorophenyl acrylate) Functionalized SiO2 Beads for Protein Purification.
J Vis Exp; 2019 Apr; (146):. PubMed ID: 31038480
[TBL] [Abstract][Full Text] [Related]
7. Chemical Items Used for Preparing Tissue-Mimicking Material of Wall-Less Flow Phantom for Doppler Ultrasound Imaging.
Oglat AA; Matjafri MZ; Suardi N; Oqlat MA; Abdelrahman MA; Oqlat AA; Farhat OF; Alkhateb BN; Abdalrheem R; Ahmad MS; Abujazar MYM
J Med Ultrasound; 2018; 26(3):123-127. PubMed ID: 30283197
[TBL] [Abstract][Full Text] [Related]
8. Compatibility and Validation of a Recent Developed Artificial Blood through the Vascular Phantom Using Doppler Ultrasound Color- and Motion-mode Techniques.
Alshipli M; Sayah MA; Oglat AA
J Med Ultrasound; 2020; 28(4):219-224. PubMed ID: 33659160
[TBL] [Abstract][Full Text] [Related]
9. Development and characterization of a blood mimicking fluid for high intensity focused ultrasound.
Liu Y; Maruvada S; King RL; Herman BA; Wear KA
J Acoust Soc Am; 2008 Sep; 124(3):1803-10. PubMed ID: 19045670
[TBL] [Abstract][Full Text] [Related]
10. Doppler backscatter properties of a blood-mimicking fluid for Doppler performance assessment.
Ramnarine KV; Hoskins PR; Routh HF; Davidson F
Ultrasound Med Biol; 1999 Jan; 25(1):105-10. PubMed ID: 10048807
[TBL] [Abstract][Full Text] [Related]
11. Glycerol-in-SEBS gel as a material to manufacture stable wall-less vascular phantom for ultrasound and photoacoustic imaging.
Cabrelli LC; Uliana JH; da Cruz Junior LB; Bachmann L; Carneiro AAO; Pavan TZ
Biomed Phys Eng Express; 2021 Sep; 7(6):. PubMed ID: 34496358
[TBL] [Abstract][Full Text] [Related]
12. A Review of Blood-mimicking Fluid Properties Using Doppler Ultrasound Applications.
Oglat AA
J Med Ultrasound; 2022; 30(4):251-256. PubMed ID: 36844776
[TBL] [Abstract][Full Text] [Related]
13. Erratum: Eyestalk Ablation to Increase Ovarian Maturation in Mud Crabs.
J Vis Exp; 2023 May; (195):. PubMed ID: 37235796
[TBL] [Abstract][Full Text] [Related]
14. Use of an ultrasound blood-mimicking fluid for Doppler investigations of turbulence in vitro.
Thorne ML; Poepping TL; Rankin RN; Steinman DA; Holdsworth DW
Ultrasound Med Biol; 2008 Jul; 34(7):1163-73. PubMed ID: 18343015
[TBL] [Abstract][Full Text] [Related]
15. [Standard technical specifications for methacholine chloride (Methacholine) bronchial challenge test (2023)].
; ;
Zhonghua Jie He He Hu Xi Za Zhi; 2024 Feb; 47(2):101-119. PubMed ID: 38309959
[TBL] [Abstract][Full Text] [Related]
16. High throughput single-cell and multiple-cell micro-encapsulation.
Lagus TP; Edd JF
J Vis Exp; 2012 Jun; (64):e4096. PubMed ID: 22733254
[TBL] [Abstract][Full Text] [Related]
17. Testing a new surfactant in a widely-used blood mimic for ultrasound flow imaging.
Zhou X; Hoskins PR
Ultrasound; 2017 Nov; 25(4):239-244. PubMed ID: 29163660
[TBL] [Abstract][Full Text] [Related]
18. Development of Ultrasound Phantom Made of Transparent Material: Feasibility of Optical Particle Image Velocimetry.
Hashuro MSS; Tupin S; Putra NK; Daibo K; Inoue K; Ishii T; Kosukegawa H; Funamoto K; Hayase T; Ohta M
Ultrasound Med Biol; 2023 Jun; 49(6):1385-1394. PubMed ID: 36878829
[TBL] [Abstract][Full Text] [Related]
19. Oil Gel-Based Phantom for Evaluating Quantitative Accuracy of Speed of Sound Measured in Ultrasound Computed Tomography.
Suzuki A; Tsubota Y; Wu W; Yamanaka K; Terada T; Otake Y; Kawabata K
Ultrasound Med Biol; 2019 Sep; 45(9):2554-2567. PubMed ID: 31201022
[TBL] [Abstract][Full Text] [Related]
20. In vitro study of ultrasound radiation force-driven twinkling sign using PVA-H gel and glass beads tissue-mimicking phantom.
Liu L; Funamoto K; Ozawa K; Ohta M; Hayase T; Ogasawara M
J Med Ultrason (2001); 2013 Jul; 40(3):197-203. PubMed ID: 27277236
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]