These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

214 related articles for article (PubMed ID: 30284378)

  • 1. Use of a commercial ion chamber detector array for the measurement of high spatial-resolution photon beam profiles.
    Karimnia V; Belley MD; Rodgers R; Price M
    J Appl Clin Med Phys; 2018 Nov; 19(6):323-331. PubMed ID: 30284378
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Characterization and evaluation of an integrated quality monitoring system for online quality assurance of external beam radiation therapy.
    Hoffman D; Chung E; Hess C; Stern R; Benedict S
    J Appl Clin Med Phys; 2017 Jan; 18(1):40-48. PubMed ID: 28291937
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development and clinical evaluation of an ionization chamber array with 3.5 mm pixel pitch for quality assurance in advanced radiotherapy techniques.
    Togno M; Wilkens JJ; Menichelli D; Oechsner M; Perez-Andujar A; Morin O
    Med Phys; 2016 May; 43(5):2283. PubMed ID: 27147340
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Equivalency of beam scan data collection using a 1D tank and automated couch movements to traditional 3D tank measurements.
    Knutson NC; Schmidt MC; Belley MD; Nguyen N; Price M; Mutic S; Sajo E; Li HH
    J Appl Clin Med Phys; 2018 Nov; 19(6):60-67. PubMed ID: 30188009
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dosimetric study of 2D ion chamber array matrix for the modern radiotherapy treatment verification.
    Saminathan S; Manickam R; Chandraraj V; Supe SS
    J Appl Clin Med Phys; 2010 Apr; 11(2):3076. PubMed ID: 20592695
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Commissioning and dosimetric characteristics of TrueBeam system: composite data of three TrueBeam machines.
    Chang Z; Wu Q; Adamson J; Ren L; Bowsher J; Yan H; Thomas A; Yin FF
    Med Phys; 2012 Nov; 39(11):6981-7018. PubMed ID: 23127092
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Characterization of a new transmission detector for patient individualized online plan verification and its influence on 6MV X-ray beam characteristics.
    Thoelking J; Sekar Y; Fleckenstein J; Lohr F; Wenz F; Wertz H
    Z Med Phys; 2016 Sep; 26(3):200-8. PubMed ID: 26303190
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development of an accurate EPID-based output measurement and dosimetric verification tool for electron beam therapy.
    Ding A; Xing L; Han B
    Med Phys; 2015 Jul; 42(7):4190-8. PubMed ID: 26133618
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Rounded leaf end modeling in Pinnacle VMAT treatment planning for fixed jaw linacs.
    Young LA; Yang F; Cao N; Meyer J
    J Appl Clin Med Phys; 2016 Nov; 17(6):149-162. PubMed ID: 27929490
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Assessment of the setup dependence of detector response functions for mega-voltage linear accelerators.
    Fox C; Simon T; Simon B; Dempsey JF; Kahler D; Palta JR; Liu C; Yan G
    Med Phys; 2010 Feb; 37(2):477-84. PubMed ID: 20229856
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Characterization of a two-dimensional liquid-filled ion chamber detector array used for verification of the treatments in radiotherapy.
    Markovic M; Stathakis S; Mavroidis P; Jurkovic IA; Papanikolaou N
    Med Phys; 2014 May; 41(5):051704. PubMed ID: 24784370
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dosimetric characterization for GRID collimator-based spatially fractionated radiation therapy: Dosimetric parameter acquisition and machine interchangeability investigation.
    Xu Z; Balik S; Woods K; Shen Z; Cheng C; Cui J; Gallogly H; Chang E; Lukas L; Lim A; Natsuaki Y; Ye J; Ma L; Zhang H
    J Appl Clin Med Phys; 2024 Aug; 25(8):e14410. PubMed ID: 38810092
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Pixel response-based EPID dosimetry for patient specific QA.
    Han B; Ding A; Lu M; Xing L
    J Appl Clin Med Phys; 2017 Jan; 18(1):9-17. PubMed ID: 28291939
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Characterization of a novel pulse normalization technology for beam scanning of small fields without a reference chamber.
    Baltz GC; Kirsner SM
    J Appl Clin Med Phys; 2024 Jun; 25(6):e14379. PubMed ID: 38700940
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Diamond detector versus silicon diode and ion chamber in photon beams of different energy and field size.
    Bucciolini M; Buonamici FB; Mazzocchi S; De Angelis C; Onori S; Cirrone GA
    Med Phys; 2003 Aug; 30(8):2149-54. PubMed ID: 12945980
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Beam perturbation characteristics of a 2D transmission silicon diode array, Magic Plate.
    Alrowaili ZA; Lerch ML; Petasecca M; Carolan MG; Metcalfe PE; Rosenfeld AB
    J Appl Clin Med Phys; 2016 Mar; 17(2):85-98. PubMed ID: 27074475
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Generation and verification of QFix kVue Calypso-compatible couch top model for a dedicated stereotactic linear accelerator with FFF beams.
    Gardner SJ; Gulam M; Song K; Li H; Huang Y; Zhao B; Qin Y; Snyder K; Kim J; Gordon J; Chetty IJ; Wen N
    J Appl Clin Med Phys; 2015 Jul; 16(4):163–180. PubMed ID: 26219010
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluating dosimetric accuracy of flattening filter free compensator-based IMRT: measurements with diode arrays.
    Robinson J; Opp D; Zhang G; Cashon K; Kozelka J; Hunt D; Walker L; Hoffe S; Shridhar R; Feygelman V
    Med Phys; 2012 Jan; 39(1):342-52. PubMed ID: 22225304
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of scanning resolution, detector choice and detector orientation to be used for accurate and time-efficient commissioning of a 6MV clinical linear accelerator.
    Azhar D; Gul A; Javid MA; Hussain MM; Shehzadi NN
    Radiat Environ Biophys; 2023 Mar; 62(1):83-96. PubMed ID: 36520198
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Relative dosimetry with an MR-linac: Response of ion chambers, diamond, and diode detectors for off-axis, depth dose, and output factor measurements.
    O'Brien DJ; Dolan J; Pencea S; Schupp N; Sawakuchi GO
    Med Phys; 2018 Feb; 45(2):884-897. PubMed ID: 29178457
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.