These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 30286629)

  • 1. Indirect reduction screws: a technique to aid reduction in intramedullary nailing.
    Sivakumar BS; Athreya PJ; Ruff SJ
    Ann R Coll Surg Engl; 2019 Mar; 101(3):226-227. PubMed ID: 30286629
    [No Abstract]   [Full Text] [Related]  

  • 2. Current status of locked intramedullary nailing: a review.
    Browner BD; Cole JD
    J Orthop Trauma; 1987; 1(2):183-95. PubMed ID: 3333517
    [No Abstract]   [Full Text] [Related]  

  • 3. The Poller Screw Technique: A Method of Fine-Tuning the Reduction in Locked Nailing.
    Koller T; Mühlebach J; Livingston A; Boopalan PRJVC; Iselin LD
    J Foot Ankle Surg; 2020; 59(3):638-640. PubMed ID: 32354521
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Clamped percutaneous Poller screws to assist intramedullary nailing of proximal third tibia shaft fractures.
    Abdalaziz H; Bates P; Iliadis A; Vris A
    Ann R Coll Surg Engl; 2022 Jan; 104(1):74-75. PubMed ID: 34972495
    [No Abstract]   [Full Text] [Related]  

  • 5. Intramedullary nailing of extra-articular proximal tibia fractures.
    Hiesterman TG; Shafiq BX; Cole PA
    J Am Acad Orthop Surg; 2011 Nov; 19(11):690-700. PubMed ID: 22052645
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Intramedullary nailing with supplementary screw fixation (Grosse-Kempf technique).
    Zanasi R; Fioretta G; Rotolo F
    Ital J Orthop Traumatol; 1985 Jun; 11(2):159-64. PubMed ID: 4066286
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Controversies in the intramedullary nailing of proximal and distal tibia fractures.
    Tejwani N; Polonet D; Wolinsky PR
    J Am Acad Orthop Surg; 2014 Oct; 22(10):665-73. PubMed ID: 25281261
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Does open reduction increase the chance of infection during intramedullary nailing of closed tibial shaft fractures?
    Sharma L; Kumar V; Malhotra R
    J Orthop Trauma; 2006; 20(10):745; author reply 745. PubMed ID: 17106390
    [No Abstract]   [Full Text] [Related]  

  • 9. [Principles of intramedullary fracture stabilization. 2. Surgical technique].
    Krettek C
    Unfallchirurg; 2001 Aug; 104(8):749-69; quiz 770-1. PubMed ID: 11569157
    [No Abstract]   [Full Text] [Related]  

  • 10. A comparative biomechanical study for complex tibial plateau fractures: nailing and compression bolts versus modern and traditional plating.
    Lasanianos NG; Garnavos C; Magnisalis E; Kourkoulis S; Babis GC
    Injury; 2013 Oct; 44(10):1333-9. PubMed ID: 23601116
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fractures of the proximal third of the tibial shaft treated with intramedullary nails and blocking screws.
    Ricci WM; O'Boyle M; Borrelli J; Bellabarba C; Sanders R
    J Orthop Trauma; 2001 May; 15(4):264-70. PubMed ID: 11371791
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Techniques for intramedullary nailing of proximal tibia fractures.
    Stinner DJ; Mir H
    Orthop Clin North Am; 2014 Jan; 45(1):33-45. PubMed ID: 24267205
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Intramedullary nailing for tibial shaft fractures in adults.
    Duan X; Al-Qwbani M; Zeng Y; Zhang W; Xiang Z
    Cochrane Database Syst Rev; 2012 Jan; 1():CD008241. PubMed ID: 22258982
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reamed or unreamed nailing for closed tibial fractures. A prospective study in Tscherne C1 fractures.
    Court-Brown CM; Will E; Christie J; McQueen MM
    J Bone Joint Surg Br; 1996 Jul; 78(4):580-3. PubMed ID: 8682824
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Intramedullary nailing in opening wedge high tibial osteotomy-in vitro test for validation of a method of fixation.
    Burchard R; Katerla D; Hammer M; Pahlkötter A; Soost C; Dietrich G; Ohrndorf A; Richter W; Lengsfeld M; Christ HJ; Graw JA; Fritzen CP
    Int Orthop; 2018 Aug; 42(8):1835-1843. PubMed ID: 29392383
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Orthopaedic surgeon's nightmare: iatrogenic fractures of talus and medial malleolus following tibial nailing.
    Meena S; Trikha V; Saini P; Kumar R; Chowdhary B
    Chin J Traumatol; 2013; 16(4):243-5. PubMed ID: 23910680
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Inserting distal screws into interlocking IM nails--revisited. Methods to make it easier.
    Rabin SI; Naeni F; Robledo SL; Rabin DN
    Orthop Rev; 1993 Sep; 22(9):1059; 1062-3, 1068. PubMed ID: 8247623
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Failures of interlocking nailing. Faulty technic and complications].
    Vécsei V; Mockwitz J; Börner M; Wruhs O
    Hefte Unfallheilkd; 1983; 161():143-53. PubMed ID: 6862951
    [No Abstract]   [Full Text] [Related]  

  • 19. Treatment of distal intraarticular tibial fractures: A biomechanical evaluation of intramedullary nailing vs. angle-stable plate osteosynthesis.
    Kuhn S; Greenfield J; Arand C; Jarmolaew A; Appelmann P; Mehler D; Rommens PM
    Injury; 2015 Oct; 46 Suppl 4():S99-S103. PubMed ID: 26542874
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of the effectiveness of the angular stable locking system in patients with distal tibial fractures treated with intramedullary nailing: a multicenter randomized controlled trial.
    Höntzsch D; Schaser KD; Hofmann GO; Pohlemann T; Hem ES; Rothenbach E; Krettek C; Attal R
    J Bone Joint Surg Am; 2014 Nov; 96(22):1889-97. PubMed ID: 25410507
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.