These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

218 related articles for article (PubMed ID: 30288999)

  • 21. Closed-loop insulin delivery during pregnancy complicated by type 1 diabetes.
    Murphy HR; Elleri D; Allen JM; Harris J; Simmons D; Rayman G; Temple R; Dunger DB; Haidar A; Nodale M; Wilinska ME; Hovorka R
    Diabetes Care; 2011 Feb; 34(2):406-11. PubMed ID: 21216859
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Lived experience of older adults with type 1 diabetes using closed-loop automated insulin delivery in a randomised trial.
    Kubilay E; Trawley S; Ward GM; Fourlanos S; Grills CA; Lee MH; MacIsaac RJ; O'Neal DN; O'Regan NA; Sundararajan V; Vogrin S; Colman PG; McAuley SA
    Diabet Med; 2023 Apr; 40(4):e15020. PubMed ID: 36468784
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Night glucose control with MD-Logic artificial pancreas in home setting: a single blind, randomized crossover trial-interim analysis.
    Nimri R; Muller I; Atlas E; Miller S; Kordonouri O; Bratina N; Tsioli C; Stefanija MA; Danne T; Battelino T; Phillip M
    Pediatr Diabetes; 2014 Mar; 15(2):91-9. PubMed ID: 23944875
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Evaluation of a portable ambulatory prototype for automated overnight closed-loop insulin delivery in young people with type 1 diabetes.
    Elleri D; Allen JM; Biagioni M; Kumareswaran K; Leelarathna L; Caldwell K; Nodale M; Wilinska ME; Acerini CL; Dunger DB; Hovorka R
    Pediatr Diabetes; 2012 Sep; 13(6):449-53. PubMed ID: 22817340
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Using technology to advance type 1 diabetes care among women during the reproductive years and in pregnancy.
    Polsky S; Giordano D; Voelmle MK; Garcetti R; Garg SK
    Postgrad Med; 2016 May; 128(4):418-26. PubMed ID: 26924774
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Closed loop insulin delivery in diabetes.
    Battelino T; Omladič JŠ; Phillip M
    Best Pract Res Clin Endocrinol Metab; 2015 Jun; 29(3):315-25. PubMed ID: 26051293
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Insulin pump therapy for pregnancy: a primer.
    Bernasko J
    J Matern Fetal Neonatal Med; 2012 Jun; 25(6):552-7. PubMed ID: 22092002
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Broadening the Debate About Post-trial Access to Medical Interventions: A Qualitative Study of Participant Experiences at the End of a Trial Investigating a Medical Device to Support Type 1 Diabetes Self-Management.
    Lawton J; Blackburn M; Rankin D; Werner C; Farrington C; Hovorka R; Hallowell N
    AJOB Empir Bioeth; 2019; 10(2):100-112. PubMed ID: 30986113
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Safety, efficacy and glucose turnover of reduced prandial boluses during closed-loop therapy in adolescents with type 1 diabetes: a randomized clinical trial.
    Elleri D; Biagioni M; Allen JM; Kumareswaran K; Leelarathna L; Caldwell K; Nodale M; Wilinska ME; Haidar A; Calhoun P; Kollman C; Jackson NC; Umpleby AM; Acerini CL; Dunger DB; Hovorka R
    Diabetes Obes Metab; 2015 Dec; 17(12):1173-9. PubMed ID: 26257323
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Rollout of Closed-Loop Technology to Pregnant Women with Type 1 Diabetes: Healthcare Professionals' Views About Potential Challenges and Solutions.
    Rankin D; Hart RI; Kimbell B; Barnard-Kelly K; Brackenridge A; Byrne C; Collett C; Dover AR; Hartnell S; Hunt KF; Lee TTM; Lindsay RS; McCance DR; McKelvey A; Rayman G; Reynolds RM; Scott EM; White SL; Hovorka R; Murphy HR; Lawton J
    Diabetes Technol Ther; 2023 Apr; 25(4):260-269. PubMed ID: 36662589
    [No Abstract]   [Full Text] [Related]  

  • 31. Case series of a hybrid closed-loop system used in pregnancies in clinical practice.
    Polsky S; Akturk HK
    Diabetes Metab Res Rev; 2020 Mar; 36(3):e3248. PubMed ID: 31758630
    [TBL] [Abstract][Full Text] [Related]  

  • 32. New closed-loop insulin systems.
    Boughton CK; Hovorka R
    Diabetologia; 2021 May; 64(5):1007-1015. PubMed ID: 33550442
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Lower plasma insulin levels during overnight closed-loop in school children with type 1 diabetes: Potential advantage? A randomized cross-over trial.
    Schierloh U; Wilinska ME; Pit-Ten Cate IM; Baumann P; Hovorka R; De Beaufort C;
    PLoS One; 2019; 14(3):e0212013. PubMed ID: 30849076
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Safety and efficacy of 24-h closed-loop insulin delivery in well-controlled pregnant women with type 1 diabetes: a randomized crossover case series.
    Murphy HR; Kumareswaran K; Elleri D; Allen JM; Caldwell K; Biagioni M; Simmons D; Dunger DB; Nodale M; Wilinska ME; Amiel SA; Hovorka R
    Diabetes Care; 2011 Dec; 34(12):2527-9. PubMed ID: 22011408
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Experiences of continuous subcutaneous insulin infusion in pregnant women with type 1 diabetes during delivery from four Italian centers: a retrospective observational study.
    Fresa R; Visalli N; Di Blasi V; Cavallaro V; Ansaldi E; Trifoglio O; Abbruzzese S; Bongiovanni M; Agrusta M; Napoli A
    Diabetes Technol Ther; 2013 Apr; 15(4):328-34. PubMed ID: 23537417
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Feasibility of Long-Term Closed-Loop Control: A Multicenter 6-Month Trial of 24/7 Automated Insulin Delivery.
    Kovatchev B; Cheng P; Anderson SM; Pinsker JE; Boscari F; Buckingham BA; Doyle FJ; Hood KK; Brown SA; Breton MD; Chernavvsky D; Bevier WC; Bradley PK; Bruttomesso D; Del Favero S; Calore R; Cobelli C; Avogaro A; Ly TT; Shanmugham S; Dassau E; Kollman C; Lum JW; Beck RW
    Diabetes Technol Ther; 2017 Jan; 19(1):18-24. PubMed ID: 27982707
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Continuous Glucose Monitoring: A Review of Recent Studies Demonstrating Improved Glycemic Outcomes.
    Rodbard D
    Diabetes Technol Ther; 2017 Jun; 19(S3):S25-S37. PubMed ID: 28585879
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Closing the Loop on Exercise in Type 1 Diabetes.
    Bally L; Thabit H
    Curr Diabetes Rev; 2018; 14(3):257-265. PubMed ID: 28245784
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The "Glucositter" overnight automated closed loop system for type 1 diabetes: a randomized crossover trial.
    Nimri R; Danne T; Kordonouri O; Atlas E; Bratina N; Biester T; Avbelj M; Miller S; Muller I; Phillip M; Battelino T
    Pediatr Diabetes; 2013 May; 14(3):159-67. PubMed ID: 23448393
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Parental attitudes towards overnight closed-loop glucose control in children with type 1 diabetes.
    Elleri D; Acerini CL; Allen JM; Hayes J; Pesterfield C; Wilinska ME; Dunger DB; Hovorka R
    Diabetes Technol Ther; 2010 Jan; 12(1):35-9. PubMed ID: 20082583
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.