BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

207 related articles for article (PubMed ID: 30291836)

  • 1. Characterization of recombinant monoclonal antibody charge variants using WCX chromatography, icIEF and LC-MS/MS.
    Liu H; Ren W; Zong L; Zhang J; Wang Y
    Anal Biochem; 2019 Jan; 564-565():1-12. PubMed ID: 30291836
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Characterization of Recombinant Monoclonal Antibody Charge Variants Using OFFGEL Fractionation, Weak Anion Exchange Chromatography, and Mass Spectrometry.
    Neill A; Nowak C; Patel R; Ponniah G; Gonzalez N; Miano D; Liu H
    Anal Chem; 2015 Jun; 87(12):6204-11. PubMed ID: 25977987
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fractionation and online mass spectrometry based on imaged capillary isoelectric focusing (icIEF) for characterizing charge heterogeneity of therapeutic antibody.
    Kwok T; Zhou M; Schaefer A; Bo T; Li V; Huang T; Chen T
    Anal Methods; 2023 Jan; 15(4):411-418. PubMed ID: 36537584
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Cutting-edge mass spectrometry strategy based on imaged capillary isoelectric focusing (icIEF) technology for characterizing charge heterogeneity of monoclonal antibody.
    Zhang X; Chen T; Li V; Bo T; Du M; Huang T
    Anal Biochem; 2023 Jan; 660():114961. PubMed ID: 36341769
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Imaged capillary isoelectric focusing (icIEF) tandem high resolution mass spectrometry for charged heterogeneity of protein drugs in biopharmaceutical discovery.
    Zhang X; Kwok T; Zhou M; Du M; Li V; Bo T; Huang T; Chen T
    J Pharm Biomed Anal; 2023 Feb; 224():115178. PubMed ID: 36435084
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Characterization of the acidic species of a monoclonal antibody using weak cation exchange chromatography and LC-MS.
    Ponniah G; Kita A; Nowak C; Neill A; Kori Y; Rajendran S; Liu H
    Anal Chem; 2015 Sep; 87(17):9084-92. PubMed ID: 26222016
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mass Spectrometry-Based Charge Heterogeneity Characterization of Therapeutic mAbs with Imaged Capillary Isoelectric Focusing and Ion-Exchange Chromatography as Separation Techniques.
    Wu G; Yu C; Wang W; Du J; Fu Z; Xu G; Li M; Wang L
    Anal Chem; 2023 Jan; 95(4):2548-2560. PubMed ID: 36656605
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Characterization of charge variants of a monoclonal antibody using weak anion exchange chromatography at subunit levels.
    Ponniah G; Nowak C; Neill A; Liu H
    Anal Biochem; 2017 Mar; 520():49-57. PubMed ID: 28024755
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Characterization of recombinant monoclonal antibody variants detected by hydrophobic interaction chromatography and imaged capillary isoelectric focusing electrophoresis.
    King C; Patel R; Ponniah G; Nowak C; Neill A; Gu Z; Liu H
    J Chromatogr B Analyt Technol Biomed Life Sci; 2018 May; 1085():96-103. PubMed ID: 29649755
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Impact of linker-drug on ion exchange chromatography separation of antibody-drug conjugates.
    Zhang Z; Zhou S; Han L; Zhang Q; Pritts WA
    MAbs; 2019; 11(6):1113-1121. PubMed ID: 31238787
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Charge variants characterization of a monoclonal antibody by ion exchange chromatography coupled on-line to native mass spectrometry: Case study after a long-term storage at +5°C.
    Leblanc Y; Ramon C; Bihoreau N; Chevreux G
    J Chromatogr B Analyt Technol Biomed Life Sci; 2017 Mar; 1048():130-139. PubMed ID: 28242492
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hyphenation of strong cation exchange chromatography to native mass spectrometry for high throughput online characterization of charge heterogeneity of therapeutic monoclonal antibodies.
    Ma F; Raoufi F; Bailly MA; Fayadat-Dilman L; Tomazela D
    MAbs; 2020; 12(1):1763762. PubMed ID: 32370592
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Detection and identification of a serine to arginine sequence variant in a therapeutic monoclonal antibody.
    Ren D; Zhang J; Pritchett R; Liu H; Kyauk J; Luo J; Amanullah A
    J Chromatogr B Analyt Technol Biomed Life Sci; 2011 Oct; 879(27):2877-84. PubMed ID: 21900054
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Charge variant native mass spectrometry benefits mass precision and dynamic range of monoclonal antibody intact mass analysis.
    Bailey AO; Han G; Phung W; Gazis P; Sutton J; Josephs JL; Sandoval W
    MAbs; 2018; 10(8):1214-1225. PubMed ID: 30339478
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Rapid preparative separation of monoclonal antibody charge variants using laterally-fed membrane chromatography.
    Sadavarte R; Madadkar P; Filipe CD; Ghosh R
    J Chromatogr B Analyt Technol Biomed Life Sci; 2018 Jan; 1073():27-33. PubMed ID: 29232608
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A study in glycation of a therapeutic recombinant humanized monoclonal antibody: where it is, how it got there, and how it affects charge-based behavior.
    Quan C; Alcala E; Petkovska I; Matthews D; Canova-Davis E; Taticek R; Ma S
    Anal Biochem; 2008 Feb; 373(2):179-91. PubMed ID: 18158144
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Characterization of the acidic species of a monoclonal antibody using free flow electrophoresis fractionation and mass spectrometry.
    Liu S; Madren S; Feng P; Sosic Z
    J Pharm Biomed Anal; 2020 Jun; 185():113217. PubMed ID: 32145540
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Determination of isoelectric points and relative charge variants of 23 therapeutic monoclonal antibodies.
    Goyon A; Excoffier M; Janin-Bussat MC; Bobaly B; Fekete S; Guillarme D; Beck A
    J Chromatogr B Analyt Technol Biomed Life Sci; 2017 Oct; 1065-1066():119-128. PubMed ID: 28961486
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Rapid identification of an antibody DNA construct rearrangement sequence variant by mass spectrometry.
    Scott RA; Rogers R; Balland A; Brady LJ
    MAbs; 2014; 6(6):1453-63. PubMed ID: 25484040
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Correlating charge heterogeneity data generated by agarose gel isoelectric focusing and ion exchange chromatography methods.
    Parekh BS; Srivastava A; Sundaram S; Ching-Heish M; Goldstein J; Barry M; Zhou Q
    J Chromatogr B Analyt Technol Biomed Life Sci; 2018 Jan; 1073():1-9. PubMed ID: 29232605
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.