These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

250 related articles for article (PubMed ID: 30293185)

  • 1. Retentive force of PEEK secondary crowns on zirconia primary crowns over time.
    Schubert O; Reitmaier J; Schweiger J; Erdelt K; Güth JF
    Clin Oral Investig; 2019 May; 23(5):2331-2338. PubMed ID: 30293185
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Retentive force of a conical crown with CAD/CAM-fabricated PEEK and zirconia secondary crowns on titanium implant abutments.
    Kamel A; Yamazaki T; Murakami N; Lyu H; Komine K; Badr A; Fekry G; Takahashi H; Wakabayashi N
    Dent Mater J; 2023 May; 42(3):336-342. PubMed ID: 36709987
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vitro investigations on retention force behavior of conventional and modern double crown systems.
    Luft V; Pospiech P; Schurig A; Schmitter M
    Dent Mater; 2021 Jan; 37(1):191-200. PubMed ID: 33276956
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Impact of material combinations and removal and insertion cycles on the retention force of telescopic systems.
    Micovic Soldatovic D; Bitter M; Meinen J; Huth KC; Liebermann A; Stawarczyk B
    Clin Oral Investig; 2023 Jul; 27(7):4007-4016. PubMed ID: 37086284
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of coping materials zirconia or polyetheretherketone with different techniques of fabrication on vertical marginal gap and fracture resistance of posterior crowns with composite veneering.
    Emam M; Metwally MF
    BMC Oral Health; 2023 Aug; 23(1):546. PubMed ID: 37559037
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Retentive strength of implant-supported CAD-CAM lithium disilicate crowns on zirconia custom abutments using 6 different cements.
    Sellers K; Powers JM; Kiat-Amnuay S
    J Prosthet Dent; 2017 Feb; 117(2):247-252. PubMed ID: 27677215
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fracture Resistance of Titanium, Zirconia, and Ceramic-Reinforced Polyetheretherketone Implant Abutments Supporting CAD/CAM Monolithic Lithium Disilicate Ceramic Crowns After Aging.
    Atsü SS; Aksan ME; Bulut AC
    Int J Oral Maxillofac Implants; 2019; 34(3):622–630. PubMed ID: 30716141
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Retentive strength of two-piece CAD/CAM zirconia implant abutments.
    Gehrke P; Alius J; Fischer C; Erdelt KJ; Beuer F
    Clin Implant Dent Relat Res; 2014 Dec; 16(6):920-5. PubMed ID: 23527950
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Retention forces between primary and secondary CAD/CAM manufactured telescopic crowns: an in vitro comparison of common material combinations.
    Schimmel M; Walther M; Al-Haj Husain N; Igarashi K; Wittneben J; Abou-Ayash S
    Clin Oral Investig; 2021 Nov; 25(11):6297-6307. PubMed ID: 33834311
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of different combinations of CAD-CAM crown and customized abutment materials on the force absorption capacity in implant supported restorations - In vitro study.
    Taha D; Cesar PF; Sabet A
    Dent Mater; 2022 Jan; 38(1):e10-e18. PubMed ID: 34952710
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of different fabrication techniques on the marginal precision of polyetheretherketone single-crown copings.
    Attia MA; Shokry TE
    J Prosthet Dent; 2020 Nov; 124(5):565.e1-565.e7. PubMed ID: 32636071
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In-vitro fatigue and fracture testing of CAD/CAM-materials in implant-supported molar crowns.
    Preis V; Hahnel S; Behr M; Bein L; Rosentritt M
    Dent Mater; 2017 Apr; 33(4):427-433. PubMed ID: 28185678
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Retentive force of conical crowns combining zirconia and fiber-reinforced composite.
    Tasaka A; Rues S; Schwindling FS; Rammelsberg P; Yamashita S
    J Dent; 2022 Sep; 124():104222. PubMed ID: 35820502
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Influence of Different CAD/CAM Crown Materials on the Fracture of Custom-Made Titanium and Zirconia Implant Abutments After Artificial Aging.
    Elsayed A; Farrag G; Chaar MS; Abdelnabi N; Kern M
    Int J Prosthodont; 2019; 32(1):91-96. PubMed ID: 30677119
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Parameters affecting retentive force of electroformed double-crown systems.
    Beuer F; Edelhoff D; Gernet W; Naumann M
    Clin Oral Investig; 2010 Apr; 14(2):129-35. PubMed ID: 19343381
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Influence of internal-gap width and cement type on the retentive force of zirconia copings in pullout testing.
    Son YH; Han CH; Kim S
    J Dent; 2012 Oct; 40(10):866-72. PubMed ID: 22819954
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Retention Load of Telescopic Crowns with Different Taper Angles between Cobalt-Chromium and Polyetheretherketone Made with Three Different Manufacturing Processes Examined by Pull-Off Test.
    Wagner C; Stock V; Merk S; Schmidlin PR; Roos M; Eichberger M; Stawarczyk B
    J Prosthodont; 2018 Feb; 27(2):162-168. PubMed ID: 27037795
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Retentive force of telescopic crowns combining fiber-reinforced composite and zirconia.
    Tasaka A; Schwindling FS; Rues S; Rammelsberg P; Yamashita S
    J Prosthodont Res; 2022 Apr; 66(2):265-271. PubMed ID: 34349081
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fracture load of monolithic CAD/CAM lithium disilicate ceramic crowns and veneered zirconia crowns as a posterior implant restoration.
    Kim JH; Lee SJ; Park JS; Ryu JJ
    Implant Dent; 2013 Feb; 22(1):66-70. PubMed ID: 23296031
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Retention of CAD/CAM all-ceramic crowns on prefabricated implant abutments: an in vitro comparative study of luting agents and abutment surface area.
    Carnaggio TV; Conrad R; Engelmeier RL; Gerngross P; Paravina R; Perezous L; Powers JM
    J Prosthodont; 2012 Oct; 21(7):523-8. PubMed ID: 22469271
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.