523 related articles for article (PubMed ID: 30295537)
1. Pelvic positioning in the supine position leads to more consistent orientation of the acetabular component after total hip arthroplasty.
Grammatopoulos G; Gofton W; Cochran M; Dobransky J; Carli A; Abdelbary H; Gill HS; Beaulé PE
Bone Joint J; 2018 Oct; 100-B(10):1280-1288. PubMed ID: 30295537
[TBL] [Abstract][Full Text] [Related]
2. Supine versus lateral position for accurate positioning of acetabular cup in total hip arthroplasty using the modified Watson-Jones approach: A randomized single-blind controlled trial.
Takada R; Jinno T; Miyatake K; Hirao M; Yagishita K; Yoshii T; Okawa A
Orthop Traumatol Surg Res; 2019 Sep; 105(5):915-922. PubMed ID: 31204181
[TBL] [Abstract][Full Text] [Related]
3. Acetabular component orientation in intra- and postoperative positions in total hip arthroplasty.
Hayakawa K; Minoda Y; Aihara M; Sakawa A; Ohzono K; Tada K
Arch Orthop Trauma Surg; 2009 Sep; 129(9):1151-6. PubMed ID: 18427818
[TBL] [Abstract][Full Text] [Related]
4. Digital Radiography in Total Hip Arthroplasty: Technique and Radiographic Results.
Penenberg BL; Samagh SP; Rajaee SS; Woehnl A; Brien WW
J Bone Joint Surg Am; 2018 Feb; 100(3):226-235. PubMed ID: 29406344
[TBL] [Abstract][Full Text] [Related]
5. Acetabular and Femoral Anteversions in Standing Position are Outside the Proposed Safe Zone After Total Hip Arthroplasty.
Lazennec JY; Thauront F; Robbins CB; Pour AE
J Arthroplasty; 2017 Nov; 32(11):3550-3556. PubMed ID: 28697862
[TBL] [Abstract][Full Text] [Related]
6. Variability of Pelvic Orientation in the Lateral Decubitus Position: Are External Alignment Guides Trustworthy?
Otero JE; Fehring KA; Martin JR; Odum SM; Fehring TK
J Arthroplasty; 2018 Nov; 33(11):3496-3501. PubMed ID: 30150153
[TBL] [Abstract][Full Text] [Related]
7. Changes in acetabular orientation during total hip arthroplasty.
Schloemann DT; Edelstein AI; Barrack RL
Bone Joint J; 2019 Jun; 101-B(6_Supple_B):45-50. PubMed ID: 31146568
[TBL] [Abstract][Full Text] [Related]
8. Accuracy of cup placement and pelvic motion in total hip arthroplasty in the lateral decubitus position using a new computed tomography-based navigation system with augmented reality technology.
Naito Y; Hasegawa M; Tone S; Wakabayashi H; Sudo A
Arch Orthop Trauma Surg; 2024 May; 144(5):2381-2389. PubMed ID: 38554208
[TBL] [Abstract][Full Text] [Related]
9. Does fluoroscopy with anterior hip arthroplasty decrease acetabular cup variability compared with a nonguided posterior approach?
Rathod PA; Bhalla S; Deshmukh AJ; Rodriguez JA
Clin Orthop Relat Res; 2014 Jun; 472(6):1877-85. PubMed ID: 24549773
[TBL] [Abstract][Full Text] [Related]
10. Functional acetabular component position with supine total hip replacement.
Eilander W; Harris SJ; Henkus HE; Cobb JP; Hogervorst T
Bone Joint J; 2013 Oct; 95-B(10):1326-31. PubMed ID: 24078527
[TBL] [Abstract][Full Text] [Related]
11. Risk factors for increased sagittal pelvic motion causing unfavourable orientation of the acetabular component in patients undergoing total hip arthroplasty.
Langston J; Pierrepont J; Gu Y; Shimmin A
Bone Joint J; 2018 Jul; 100-B(7):845-852. PubMed ID: 29954196
[TBL] [Abstract][Full Text] [Related]
12. Adoption of Robotic vs Fluoroscopic Guidance in Total Hip Arthroplasty: Is Acetabular Positioning Improved in the Learning Curve?
Kamara E; Robinson J; Bas MA; Rodriguez JA; Hepinstall MS
J Arthroplasty; 2017 Jan; 32(1):125-130. PubMed ID: 27499519
[TBL] [Abstract][Full Text] [Related]
13. Standing or supine x-rays after total hip replacement - when is the safe zone not safe?
Au J; Perriman DM; Neeman TM; Smith PN
Hip Int; 2014 Dec; 24(6):616-23. PubMed ID: 25096454
[TBL] [Abstract][Full Text] [Related]
14. What Safe Zone? The Vast Majority of Dislocated THAs Are Within the Lewinnek Safe Zone for Acetabular Component Position.
Abdel MP; von Roth P; Jennings MT; Hanssen AD; Pagnano MW
Clin Orthop Relat Res; 2016 Feb; 474(2):386-91. PubMed ID: 26150264
[TBL] [Abstract][Full Text] [Related]
15. Variation in functional pelvic tilt in patients undergoing total hip arthroplasty.
Pierrepont J; Hawdon G; Miles BP; Connor BO; Baré J; Walter LR; Marel E; Solomon M; McMahon S; Shimmin AJ
Bone Joint J; 2017 Feb; 99-B(2):184-191. PubMed ID: 28148659
[TBL] [Abstract][Full Text] [Related]
16. Fluoroscopy assessment during anterior minimally invasive hip replacement is more accurate than with the posterior approach.
Ji W; Stewart N
Int Orthop; 2016 Jan; 40(1):21-7. PubMed ID: 25957590
[TBL] [Abstract][Full Text] [Related]
17. Quantitative Effect of Pelvic Position on Radiographic Assessment of Acetabular Component Position.
Delagrammaticas DE; Alvi HM; Kaat AJ; Sullivan RR; Stover MD; Manning DW
J Arthroplasty; 2018 Feb; 33(2):608-614.e1. PubMed ID: 29066106
[TBL] [Abstract][Full Text] [Related]
18. Intra-operative digital imaging: assuring the alignment of components when undertaking total hip arthroplasty.
Hambright D; Hellman M; Barrack R
Bone Joint J; 2018 Jan; 100-B(1 Supple A):36-43. PubMed ID: 29292338
[TBL] [Abstract][Full Text] [Related]
19. Does Acetabular Coverage Vary Between the Supine and Standing Positions in Patients with Hip Dysplasia?
Tachibana T; Fujii M; Kitamura K; Nakamura T; Nakashima Y
Clin Orthop Relat Res; 2019 Nov; 477(11):2455-2466. PubMed ID: 31389893
[TBL] [Abstract][Full Text] [Related]
20. Acetabular Anteversion Changes Due to Spinal Deformity Correction: Bridging the Gap Between Hip and Spine Surgeons.
Buckland AJ; Vigdorchik J; Schwab FJ; Errico TJ; Lafage R; Ames C; Bess S; Smith J; Mundis GM; Lafage V
J Bone Joint Surg Am; 2015 Dec; 97(23):1913-20. PubMed ID: 26631991
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]