These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

213 related articles for article (PubMed ID: 30297068)

  • 1. Ventricular Assist Device Infections.
    Aslam S
    Cardiol Clin; 2018 Nov; 36(4):507-517. PubMed ID: 30297068
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Risk of left ventricular assist device driveline infection: A systematic literature review.
    Pavlovic NV; Randell T; Madeira T; Hsu S; Zinoviev R; Abshire M
    Heart Lung; 2019; 48(2):90-104. PubMed ID: 30573195
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Incidence of Infection and Antimicrobial Consumption in Ventricular Assist Device (VAD) Recipients at the Prince Charles Hospital (TPCH): A Retrospective Analysis.
    Belz S; Fisquet S; Ahuja A; Hay K; Lavana J
    Heart Lung Circ; 2020 Aug; 29(8):1234-1240. PubMed ID: 32179022
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Left ventricular assist device driveline infections.
    Pereda D; Conte JV
    Cardiol Clin; 2011 Nov; 29(4):515-27. PubMed ID: 22062200
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Mycobacterium abscessus Left Ventricle Assist Device Driveline Infections: An Emerging Pathogen?
    Nunez Breton JD; Hernandez G; Simkins J; Chaparro SV
    Transpl Infect Dis; 2018 Oct; 20(5):e12957. PubMed ID: 29896814
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A review of infections in patients with left ventricular assist devices: prevention, diagnosis and management.
    Trachtenberg BH; Cordero-Reyes A; Elias B; Loebe M
    Methodist Debakey Cardiovasc J; 2015; 11(1):28-32. PubMed ID: 25793027
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Low Incidence of Pump-Related Infections in Jarvik 2000 Ventricular Assist Device Recipients with a Subcostal Driveline Exit Site.
    Letsou GV; Anand J; Ogburn E; Shah RM; Ganapathy AV; Cohn WE; Loor G; Frazier OH
    Tex Heart Inst J; 2019 Jun; 46(3):179-182. PubMed ID: 31708699
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Infection control measures and surveillance of patients with ventricular assist devices].
    Mattner F; Chaberny IF; Mattner L; Gastmeier P; Tessmann R; Strüber M
    Anaesthesist; 2007 May; 56(5):429-36. PubMed ID: 17431552
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Prevention of percutaneous driveline infection after left ventricular assist device implantation: prophylactic antibiotics are not necessary.
    Stulak JM; Maltais S; Cowger J; Joyce LD; Daly RC; Park SJ; Aaronson KD; Pagani FD
    ASAIO J; 2013; 59(6):570-4. PubMed ID: 24172262
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Multidrug-Resistant Organism Infections in Patients with Left Ventricular Assist Devices.
    Donahey EE; Polly DM; Vega JD; Lyon M; Butler J; Nguyen D; Pekarek A; Wittersheim K; Kilgo P; Paciullo CA
    Tex Heart Inst J; 2015 Dec; 42(6):522-7. PubMed ID: 26664303
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Prevention and early treatment of driveline infections in ventricular assist device patients - The DESTINE staging proposal and the first standard of care protocol.
    Bernhardt AM; Schlöglhofer T; Lauenroth V; Mueller F; Mueller M; Schoede A; Klopsch C;
    J Crit Care; 2020 Apr; 56():106-112. PubMed ID: 31896443
    [TBL] [Abstract][Full Text] [Related]  

  • 12. New Treatment for Driveline Infection Following Implantation of a Ventricular Assist Device.
    Sezai A; Unosawa S; Taoka M; Osaka S; Kitazumi Y; Suzuki K; Nakai T; Tanaka M
    Heart Surg Forum; 2020 Mar; 23(2):E132-E134. PubMed ID: 32364899
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Clinical outcomes associated with chronic antimicrobial suppression therapy in patients with continuous-flow left ventricular assist devices.
    Jennings DL; Chopra A; Chambers R; Morgan JA
    Artif Organs; 2014 Oct; 38(10):875-9. PubMed ID: 24571683
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A retrospective study of left ventricular assist device-related infections.
    Bentz B; Hupcey JE; Polomano RC; Boehmer JP
    J Cardiovasc Manag; 2004; 15(1):9-16. PubMed ID: 14976692
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Driveline insulation as a conduit for left ventricular assist device pocket infection.
    Pinninti M; Thohan V; Sulemanjee NZ
    J Thorac Cardiovasc Surg; 2014 Jul; 148(1):e135-6. PubMed ID: 24755334
    [No Abstract]   [Full Text] [Related]  

  • 16. Current concepts in the diagnosis and management of left ventricular assist device infections.
    Nienaber J; Wilhelm MP; Sohail MR
    Expert Rev Anti Infect Ther; 2013 Feb; 11(2):201-10. PubMed ID: 23409825
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Driveline Wound Care: Key to the Long-Term Use of Implantable Ventricular Assist Devices].
    Huang HC; Wang CH; Tsai FC
    Hu Li Za Zhi; 2019 Aug; 66(4):87-94. PubMed ID: 31342505
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Epidemiology of infection in mechanical circulatory support: A global analysis from the ISHLT Mechanically Assisted Circulatory Support Registry.
    Hannan MM; Xie R; Cowger J; Schueler S; de By T; Dipchand AI; Chu VH; Cantor RS; Koval CE; Krabatsch T; Hayward CS; Nakatani T; Kirklin JK
    J Heart Lung Transplant; 2019 Apr; 38(4):364-373. PubMed ID: 30733158
    [TBL] [Abstract][Full Text] [Related]  

  • 19. New Treatment for Percutaneous Sites in Patients with a Ventricular Assist Device: Nihon University Crystal Violet Method.
    Sezai A; Niino T; Osaka S; Yaoita H; Arimoto M; Hata H; Shiono M
    Ann Thorac Cardiovasc Surg; 2016 Aug; 22(4):246-50. PubMed ID: 27086670
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Editorial comments on "left-ventricular assist device driveline infections".
    Elefteriades JA
    Cardiol Clin; 2011 Nov; 29(4):529. PubMed ID: 22062201
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 11.