21. Comparison of Isocentric C-Arm 3-Dimensional Navigation and Conventional Fluoroscopy for Percutaneous Retrograde Screwing for Anterior Column Fracture of Acetabulum: An Observational Study. He J; Tan G; Zhou D; Sun L; Li Q; Yang Y; Liu P Medicine (Baltimore); 2016 Jan; 95(2):e2470. PubMed ID: 26765448 [TBL] [Abstract][Full Text] [Related]
22. Three-dimensional navigation-guided percutaneous screw fixation for nondisplaced and displaced pelvi-acetabular fractures in a major trauma centre. Chui KH; Chan CCD; Ip KC; Lee KB; Li W Int Orthop; 2018 Jun; 42(6):1387-1395. PubMed ID: 29063184 [TBL] [Abstract][Full Text] [Related]
24. Efficacy comparison between iliosacral screw fixation of the posterior pelvic ring fracture with the assistance of modified percutaneous three-dimensional printing guide template and conventional fluoroscopy. Liu F; Lei Q; Cai L; Jiang M; Yang H; Wang K; Ding Z; Liu W Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2023 Nov; 48(11):1703-1710. PubMed ID: 38432861 [TBL] [Abstract][Full Text] [Related]
25. Fracture reduction and screw position after 3D-navigated and conventional fluoroscopy-assisted percutaneous management of acetabular fractures: a retrospective comparative study. Swartman B; Pelzer J; Beisemann N; Schnetzke M; Keil H; Vetter SY; Grützner PA; Franke J Arch Orthop Trauma Surg; 2021 Apr; 141(4):593-602. PubMed ID: 32519074 [TBL] [Abstract][Full Text] [Related]
26. Minimally invasive screw fixation is as stable as anterior plating in acetabular T-Type fractures - a biomechanical study. Becker CA; Kammerlander C; Cavalcanti Kußmaul A; Dotzauer F; Woiczinski M; Rubenbauer B; Sommer F; Linhart C; Weidert S; Zeckey C; Greiner A Orthop Traumatol Surg Res; 2018 Nov; 104(7):1055-1061. PubMed ID: 30179721 [TBL] [Abstract][Full Text] [Related]
27. [Computer-assisted screw placement into the posterior pelvic ring: assessment of different navigated procedures in a cadaver trial]. Briem D; Rueger JM; Begemann PG; Halata Z; Bock T; Linhart W; Windolf J Unfallchirurg; 2006 Aug; 109(8):640-6. PubMed ID: 16897024 [TBL] [Abstract][Full Text] [Related]
28. The added value of intraoperative CT scanner and screw navigation in displaced posterior wall acetabular fracture with articular impaction. Sebaaly A; Riouallon G; Zaraa M; Jouffroy P Orthop Traumatol Surg Res; 2016 Nov; 102(7):947-950. PubMed ID: 27527248 [TBL] [Abstract][Full Text] [Related]
29. Use of 3D Navigation Versus Traditional Fluoroscopy for Posterior Pelvic Ring Fixation. Passias BJ; Grenier G; Buchan J; Buchan DR; Scheschuk J; Taylor BC Orthopedics; 2021; 44(4):229-234. PubMed ID: 34292808 [TBL] [Abstract][Full Text] [Related]
30. [Orthopedic robot based on 5G technology for remote navigation of percutaneous screw fixation in pelvic and acetabular fractures]. Zhao B; Li J; Zhao C; Su Y; Han W; Wu X; Jiang X; Wang J Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2022 Aug; 36(8):923-928. PubMed ID: 35979780 [TBL] [Abstract][Full Text] [Related]
31. Accuracy of computer-assisted iliosacral screw placement using a hybrid operating room. Richter PH; Gebhard F; Dehner C; Scola A Injury; 2016 Feb; 47(2):402-7. PubMed ID: 26708797 [TBL] [Abstract][Full Text] [Related]
32. Iliosacral screw fixation of pelvic ring disruption with tridimensional patient-specific template guidance. Liu F; Yu J; Yang H; Cai L; Chen L; Lei Q; Lei P Orthop Traumatol Surg Res; 2022 Apr; 108(2):103210. PubMed ID: 35077898 [TBL] [Abstract][Full Text] [Related]
34. Screw placement for acetabular fractures: which navigation modality (2-dimensional vs. 3-dimensional) should be used? An experimental study. Gras F; Marintschev I; Klos K; Mückley T; Hofmann GO; Kahler DM J Orthop Trauma; 2012 Aug; 26(8):466-73. PubMed ID: 22357092 [TBL] [Abstract][Full Text] [Related]
35. Three-dimensional-guided navigation percutaneous screw fixation of fragility fractures of the pelvis. Wong JSY; Lau JCK; Chui KH; Tiu KL; Lee KB; Li W J Orthop Surg (Hong Kong); 2019; 27(1):2309499019833897. PubMed ID: 30862246 [TBL] [Abstract][Full Text] [Related]
36. Accuracy of navigated and conventional iliosacral screw placement in B- and C-type pelvic ring fractures. Berger-Groch J; Lueers M; Rueger JM; Lehmann W; Thiesen D; Kolb JP; Hartel MJ; Grossterlinden LG Eur J Trauma Emerg Surg; 2020 Feb; 46(1):107-113. PubMed ID: 30030551 [TBL] [Abstract][Full Text] [Related]
37. Iliosacral screw fixation of the unstable pelvic ring injuries. Rysavý M; Pavelka T; Khayarin M; Dzupa V Acta Chir Orthop Traumatol Cech; 2010 Jun; 77(3):209-14. PubMed ID: 20619112 [TBL] [Abstract][Full Text] [Related]
38. Open reduction internal fixation versus percutaneous iliosacral screw fixation for unstable posterior pelvic ring disruptions. Elzohairy MM; Salama AM Orthop Traumatol Surg Res; 2017 Apr; 103(2):223-227. PubMed ID: 28017873 [TBL] [Abstract][Full Text] [Related]
39. Percutaneous iliosacral screwing in pelvic ring injury using three-dimensional fluoroscopy. Kim JW; Oh CW; Oh JK; Lee HJ; Min WK; Kyung HS; Yoon SH; Mun JU J Orthop Sci; 2013 Jan; 18(1):87-92. PubMed ID: 23053589 [TBL] [Abstract][Full Text] [Related]
40. Intraoperative fluoroscopic evaluation of screw placement during pelvic and acetabular surgery. Yi C; Burns S; Hak DJ J Orthop Trauma; 2014 Jan; 28(1):48-56. PubMed ID: 23360910 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]