These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

160 related articles for article (PubMed ID: 30309845)

  • 1. Balloon-Guide Catheters Are Needed for Effective Flow Reversal during Mechanical Thrombectomy.
    Nikoubashman O; Wischer D; Hennemann HM; Sandmann J; Sichtermann T; Müschenich FS; Reich A; Wiesmann M
    AJNR Am J Neuroradiol; 2018 Nov; 39(11):2077-2081. PubMed ID: 30309845
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Under Pressure: Comparison of Aspiration Techniques for Endovascular Mechanical Thrombectomy.
    Nikoubashman O; Wischer D; Hennemann HM; Büsen M; Brockmann C; Wiesmann M
    AJNR Am J Neuroradiol; 2018 May; 39(5):905-909. PubMed ID: 29650784
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of the Intracranial Flow Alteration during Manual Syringe and Continuous Pump Aspiration.
    Okada H; Matsuda Y; Malisch A; Chung J; Heiferman DM; Lopes DK
    J Stroke Cerebrovasc Dis; 2019 Sep; 28(9):2574-2579. PubMed ID: 31239220
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Initial clinical experience using the two-stage aspiration technique (TSAT) with proximal flow arrest by a balloon guiding catheter for acute ischemic stroke of the anterior circulation.
    Matsumoto H; Nishiyama H; Tetsuo Y; Takemoto H; Nakao N
    J Neurointerv Surg; 2017 Dec; 9(12):1160-1165. PubMed ID: 27899519
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Maximizing the catheter-to-vessel size optimizes distal flow control resulting in improved revascularization in vitro for aspiration thrombectomy.
    Nogueira RG; Ryan D; Mullins L; Thornton J; Fitzgerald S
    J Neurointerv Surg; 2022 Feb; 14(2):184-188. PubMed ID: 33722968
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Achievable aspiration flow rates with large balloon guide catheters during carotid artery stenting.
    Schubert T; Rivera-Rivera L; Roldan-Alzate A; Consigny D; Leitner L; Strother C; Aagaard-Kienitz B
    CVIR Endovasc; 2020 Sep; 3(1):65. PubMed ID: 32910271
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Further Development of Combined Techniques Using Stent Retrievers, Aspiration Catheters and BGC : The PROTECT
    Maegerlein C; Berndt MT; Mönch S; Kreiser K; Boeckh-Behrens T; Lehm M; Wunderlich S; Zimmer C; Friedrich B
    Clin Neuroradiol; 2020 Mar; 30(1):59-65. PubMed ID: 30413831
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Walrus Balloon Guide Catheter for Stroke Intervention: Technical Considerations and Clinical Outcomes.
    Dossani RH; Waqas M; Baig AA; Cappuzzo JM; Popoola D; Rai H; Monteiro A; Levy A; Hashmi E; Davies JM; Levy EI; Siddiqui AH
    World Neurosurg; 2021 Aug; 152():e144-e148. PubMed ID: 34033957
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reduction in distal emboli with proximal flow control during mechanical thrombectomy: a quantitative in vitro study.
    Chueh JY; Kühn AL; Puri AS; Wilson SD; Wakhloo AK; Gounis MJ
    Stroke; 2013 May; 44(5):1396-401. PubMed ID: 23493730
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A technical comparison of thrombectomy vacuum aspiration systems.
    Yaeger K; Iserson A; Singh P; Wolf J; Vidal E; Oxley T; Costa AB; Fifi JT
    J Neurointerv Surg; 2020 Jan; 12(1):72-76. PubMed ID: 31273074
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of a Balloon Guide Catheter and a Non-Balloon Guide Catheter for Mechanical Thrombectomy.
    Velasco A; Buerke B; Stracke CP; Berkemeyer S; Mosimann PJ; Schwindt W; Alcázar P; Cnyrim C; Niederstadt T; Chapot R; Heindel W
    Radiology; 2016 Jul; 280(1):169-76. PubMed ID: 26789499
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Impact of Balloon-Guiding Catheter Location on Recanalization in Patients with Acute Stroke Treated by Mechanical Thrombectomy.
    Jeong DE; Kim JW; Kim BM; Hwang W; Kim DJ
    AJNR Am J Neuroradiol; 2019 May; 40(5):840-844. PubMed ID: 30948374
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Manual aspiration thrombectomy through balloon-tipped guide catheter for rapid clot burden reduction in endovascular therapy for ICA L/T occlusion.
    Eesa M; Almekhlafi MA; Mitha AP; Wong JH; Goyal M
    Neuroradiology; 2012 Nov; 54(11):1261-5. PubMed ID: 22552837
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Mechanical thrombectomy of right internal carotid artery terminus occlusion using the ADAPT technique: impact of aspiration on parent vessel.
    Dossani RH; Tso MK; Waqas M; Rai HH; Rajah GB; Siddiqui AH
    J Neurointerv Surg; 2020 Nov; 12(11):1148. PubMed ID: 32576702
    [TBL] [Abstract][Full Text] [Related]  

  • 15. GUide sheath Advancement and aspiRation in the Distal petrocavernous internal carotid artery (GUARD) Technique during Thrombectomy Improves Reperfusion and Clinical Outcomes.
    Ansari SA; Darwish M; Abdalla RN; Cantrell DR; Shaibani A; Hurley MC; Jahromi BS; Potts MB
    AJNR Am J Neuroradiol; 2019 Aug; 40(8):1356-1362. PubMed ID: 31345939
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Necessary Catheter Diameters for Mechanical Thrombectomy with ADAPT.
    Nikoubashman O; Nikoubashman A; Büsen M; Wiesmann M
    AJNR Am J Neuroradiol; 2017 Dec; 38(12):2277-2281. PubMed ID: 29025728
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Optimizing endovascular stroke treatment: removing the microcatheter before clot retrieval with stent-retrievers increases aspiration flow.
    Nikoubashman O; Alt JP; Nikoubashman A; Büsen M; Heringer S; Brockmann C; Brockmann MA; Müller M; Reich A; Wiesmann M
    J Neurointerv Surg; 2017 May; 9(5):459-462. PubMed ID: 27084962
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Arterial Collapse during Thrombectomy for Stroke: Clinical Evidence and Experimental Findings in Human Brains and In Vivo Models.
    Liu Y; Gebrezgiabhier D; Zheng Y; Shih AJ; Chaudhary N; Pandey AS; Larco JLA; Madhani SI; Abbasi M; Shahid AH; Quinton RA; Kadirvel R; Brinjikji W; Kallmes DF; Savastano LE
    AJNR Am J Neuroradiol; 2022 Feb; 43(2):251-257. PubMed ID: 35027348
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Primary stentriever versus combined stentriever plus aspiration thrombectomy approaches: in vitro stroke model comparison.
    Mokin M; Ionita CN; Nagesh SV; Rudin S; Levy EI; Siddiqui AH
    J Neurointerv Surg; 2015 Jun; 7(6):453-7. PubMed ID: 24789594
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of modern stroke thrombectomy approaches using an in vitro cerebrovascular occlusion model.
    Mokin M; Setlur Nagesh SV; Ionita CN; Levy EI; Siddiqui AH
    AJNR Am J Neuroradiol; 2015 Mar; 36(3):547-51. PubMed ID: 25376809
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.