310 related articles for article (PubMed ID: 30319439)
1. The Relationship Between Lactate and Ventilatory Thresholds in Runners: Validity and Reliability of Exercise Test Performance Parameters.
Cerezuela-Espejo V; Courel-Ibáñez J; Morán-Navarro R; Martínez-Cava A; Pallarés JG
Front Physiol; 2018; 9():1320. PubMed ID: 30319439
[TBL] [Abstract][Full Text] [Related]
2. Validity and Reliability of Ventilatory and Blood Lactate Thresholds in Well-Trained Cyclists.
Pallarés JG; Morán-Navarro R; Ortega JF; Fernández-Elías VE; Mora-Rodriguez R
PLoS One; 2016; 11(9):e0163389. PubMed ID: 27657502
[TBL] [Abstract][Full Text] [Related]
3. A "
Garcia-Tabar I; Gorostiaga EM
Front Physiol; 2018; 9():1034. PubMed ID: 30108519
[TBL] [Abstract][Full Text] [Related]
4. A New Short Track Test to Estimate the V[Combining Dot Above]O2max and Maximal Aerobic Speed in Well-Trained Runners.
Pallarés JG; Cerezuela-Espejo V; Morán-Navarro R; Martínez-Cava A; Conesa E; Courel-Ibáñez J
J Strength Cond Res; 2019 May; 33(5):1216-1221. PubMed ID: 31033773
[TBL] [Abstract][Full Text] [Related]
5. Comparison of maximal lactate steady state with anaerobic threshold determined by various methods based on graded exercise test with 3-minute stages in elite cyclists.
Płoszczyca K; Jazic D; Piotrowicz Z; Chalimoniuk M; Langfort J; Czuba M
BMC Sports Sci Med Rehabil; 2020 Nov; 12(1):70. PubMed ID: 33292555
[TBL] [Abstract][Full Text] [Related]
6. The validity of the lactate minimum test for determination of the maximal lactate steady state.
Jones AM; Doust JH
Med Sci Sports Exerc; 1998 Aug; 30(8):1304-13. PubMed ID: 9710874
[TBL] [Abstract][Full Text] [Related]
7. Lactate Equivalent for Maximal Lactate Steady State Determination in Soccer.
Garcia-Tabar I; Rampinini E; Gorostiaga EM
Res Q Exerc Sport; 2019 Dec; 90(4):678-689. PubMed ID: 31479401
[No Abstract] [Full Text] [Related]
8. Is the Functional Threshold Power a Valid Metric to Estimate the Maximal Lactate Steady State in Cyclists?
Lillo-Beviá JR; Courel-Ibáñez J; Cerezuela-Espejo V; Morán-Navarro R; Martínez-Cava A; Pallarés JG
J Strength Cond Res; 2022 Jan; 36(1):167-173. PubMed ID: 31714462
[TBL] [Abstract][Full Text] [Related]
9. Non-exhaustive double effort test is reliable and estimates the first ventilatory threshold intensity in running exercise.
Forte LDM; Manchado-Gobatto FB; Rodrigues RCM; Gallani MC; Gobatto CA
J Sport Health Sci; 2018 Apr; 7(2):197-203. PubMed ID: 30356465
[TBL] [Abstract][Full Text] [Related]
10. Determination of the anaerobic threshold and maximal lactate steady state speed in equines using the lactate minimum speed protocol.
Gondim FJ; Zoppi CC; Pereira-da-Silva L; de Macedo DV
Comp Biochem Physiol A Mol Integr Physiol; 2007 Mar; 146(3):375-80. PubMed ID: 17234441
[TBL] [Abstract][Full Text] [Related]
11. The midpoint between ventilatory thresholds approaches maximal lactate steady state intensity in amateur cyclists.
Peinado AB; Filho DP; Díaz V; Benito PJ; Álvarez-Sánchez M; Zapico AG; Calderón FJ
Biol Sport; 2016 Dec; 33(4):373-380. PubMed ID: 28090142
[TBL] [Abstract][Full Text] [Related]
12. Relative Proximity of Critical Power and Metabolic/Ventilatory Thresholds: Systematic Review and Meta-Analysis.
Galán-Rioja MÁ; González-Mohíno F; Poole DC; González-Ravé JM
Sports Med; 2020 Oct; 50(10):1771-1783. PubMed ID: 32613479
[TBL] [Abstract][Full Text] [Related]
13. Lactate threshold concepts: how valid are they?
Faude O; Kindermann W; Meyer T
Sports Med; 2009; 39(6):469-90. PubMed ID: 19453206
[TBL] [Abstract][Full Text] [Related]
14. Perceptually Regulated Exercise Test Allows Determination of V˙O2max and Ventilatory Threshold But Not Respiratory Compensation Point In Trained Runners.
Truong P; Millet GP; Gojanovic B
Int J Sports Med; 2018 Apr; 39(4):304-313. PubMed ID: 29475209
[TBL] [Abstract][Full Text] [Related]
15. Manipulating graded exercise test variables affects the validity of the lactate threshold and [Formula: see text].
Jamnick NA; Botella J; Pyne DB; Bishop DJ
PLoS One; 2018; 13(7):e0199794. PubMed ID: 30059543
[TBL] [Abstract][Full Text] [Related]
16. Prediction of maximal lactate steady state in runners with an incremental test on the field.
Leti T; Mendelson M; Laplaud D; Flore P
J Sports Sci; 2012; 30(6):609-16. PubMed ID: 22364376
[TBL] [Abstract][Full Text] [Related]
17. Comparison between 2,000 m and 3,000 m time trials to estimate the maximal aerobic speed for collegiate runners.
Du Z; Lu W; Lang D
Front Physiol; 2022; 13():1005259. PubMed ID: 36277176
[TBL] [Abstract][Full Text] [Related]
18. Is the Tyme Wear Smart Shirt Reliable and Valid at Detecting Personalized Ventilatory Thresholds in Recreationally Active Individuals?
Gouw AH; Van Guilder GP; Cullen GG; Dalleck LC
Int J Environ Res Public Health; 2022 Jan; 19(3):. PubMed ID: 35162172
[TBL] [Abstract][Full Text] [Related]
19. Correlations between lactate and ventilatory thresholds and the maximal lactate steady state in elite cyclists.
Van Schuylenbergh R; Vanden Eynde B; Hespel P
Int J Sports Med; 2004 Aug; 25(6):403-8. PubMed ID: 15346226
[TBL] [Abstract][Full Text] [Related]
20. The influence of the regression model and final speed criteria on the reliability of lactate threshold determined by the Dmax method in endurance-trained runners.
Camargo Alves JC; Segabinazi Peserico C; Nogueira GA; Machado FA
Appl Physiol Nutr Metab; 2016 Oct; 41(10):1039-1044. PubMed ID: 27628199
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]