BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

1109 related articles for article (PubMed ID: 30322772)

  • 1. Pre-procedural fit-testing of TAVR valves using parametric modeling and 3D printing.
    Hosny A; Dilley JD; Kelil T; Mathur M; Dean MN; Weaver JC; Ripley B
    J Cardiovasc Comput Tomogr; 2019; 13(1):21-30. PubMed ID: 30322772
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quantitative Prediction of Paravalvular Leak in Transcatheter Aortic Valve Replacement Based on Tissue-Mimicking 3D Printing.
    Qian Z; Wang K; Liu S; Zhou X; Rajagopal V; Meduri C; Kauten JR; Chang YH; Wu C; Zhang C; Wang B; Vannan MA
    JACC Cardiovasc Imaging; 2017 Jul; 10(7):719-731. PubMed ID: 28683947
    [TBL] [Abstract][Full Text] [Related]  

  • 3. 3-Dimensional printing to predict paravalvular regurgitation after transcatheter aortic valve replacement.
    Reiff C; Zhingre Sanchez JD; Mattison LM; Iaizzo PA; Garcia S; Raveendran G; Gurevich S
    Catheter Cardiovasc Interv; 2020 Dec; 96(7):E703-E710. PubMed ID: 32077222
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Realistic Vascular Replicator for TAVR Procedures.
    Rotman OM; Kovarovic B; Sadasivan C; Gruberg L; Lieber BB; Bluestein D
    Cardiovasc Eng Technol; 2018 Sep; 9(3):339-350. PubMed ID: 29654509
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Impact of device-host interaction on paravalvular aortic regurgitation with different transcatheter heart valves.
    Rodríguez-Olivares R; El Faquir N; Rahhab Z; van Gils L; Ren B; Sakhi R; Geleijnse ML; van Domburg R; de Jaegere PPT; Zamorano Gómez JL; Van Mieghem NM
    Cardiovasc Revasc Med; 2019 Feb; 20(2):126-132. PubMed ID: 29779973
    [TBL] [Abstract][Full Text] [Related]  

  • 6. 3D printing based on cardiac CT assists anatomic visualization prior to transcatheter aortic valve replacement.
    Ripley B; Kelil T; Cheezum MK; Goncalves A; Di Carli MF; Rybicki FJ; Steigner M; Mitsouras D; Blankstein R
    J Cardiovasc Comput Tomogr; 2016; 10(1):28-36. PubMed ID: 26732862
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Prosthesis-Specific Predictors of Paravalvular Regurgitation after Transcatheter Aortic Valve Replacement: Impact of Calcification and Sizing on Balloon-Expandable versus Self-Expandable Transcatheter Heart Valves.
    Stähli BE; Nguyen-Kim TD; Gebhard C; Erhart L; Frauenfelder T; Tanner FC; Falk V; Landmesser U; Nietlispach F; Lüscher TF; Maier W; Binder RK
    J Heart Valve Dis; 2015 Jan; 24(1):10-21. PubMed ID: 26182615
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Bioprosthetic Valve Performance After Transcatheter Aortic Valve Replacement With Self-Expanding Versus Balloon-Expandable Valves in Large Versus Small Aortic Valve Annuli: Insights From the CHOICE Trial and the CHOICE-Extend Registry.
    Abdelghani M; Mankerious N; Allali A; Landt M; Kaur J; Sulimov DS; Merten C; Sachse S; Mehilli J; Neumann FJ; Frerker C; Kurz T; El-Mawardy M; Richardt G; Abdel-Wahab M
    JACC Cardiovasc Interv; 2018 Dec; 11(24):2507-2518. PubMed ID: 30503595
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of self-expanding and balloon-expandable transcatheter aortic valves morphology and association with paravalvular regurgitation: Evaluation using multidetector computed tomography.
    Almeida JG; Ferreira SM; Fonseca P; Dias T; Guerreiro C; Barbosa A; Teixeira P; Carvalho M; Ferreira W; Ferreira ND; Braga P; Ribeiro J; Ribeiro VG
    Catheter Cardiovasc Interv; 2018 Sep; 92(3):533-541. PubMed ID: 29105953
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Outcomes of Redo Transcatheter Aortic Valve Replacement for the Treatment of Postprocedural and Late Occurrence of Paravalvular Regurgitation and Transcatheter Valve Failure.
    Barbanti M; Webb JG; Tamburino C; Van Mieghem NM; Makkar RR; Piazza N; Latib A; Sinning JM; Won-Keun K; Bleiziffer S; Bedogni F; Kapadia S; Tchetche D; Rodés-Cabau J; Fiorina C; Nombela-Franco L; De Marco F; de Jaegere PP; Chakravarty T; Vaquerizo B; Colombo A; Svensson L; Lange R; Nickenig G; Möllmann H; Walther T; Della Rosa F; Elhmidi Y; Dvir D; Brambilla N; Immè S; Sgroi C; Gulino S; Todaro D; Pilato G; Petronio AS; Tamburino C
    Circ Cardiovasc Interv; 2016 Sep; 9(9):. PubMed ID: 27578840
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Computed Tomography-Based Oversizing Degrees and Incidence of Paravalvular Regurgitation of a New Generation Transcatheter Heart Valve.
    Blanke P; Pibarot P; Hahn R; Weissman N; Kodali S; Thourani V; Parvataneni R; Dvir D; Naoum C; Nørgaard BL; Douglas P; Jaber W; Khalique OK; Jilaihawi H; Mack M; Smith C; Leon M; Webb J; Leipsic J
    JACC Cardiovasc Interv; 2017 Apr; 10(8):810-820. PubMed ID: 28427598
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The extent of aortic annulus calcification is a predictor of postprocedural eccentricity and paravalvular regurgitation: a pre- and postinterventional cardiac computed tomography angiography study.
    Bekeredjian R; Bodingbauer D; Hofmann NP; Greiner S; Schuetz M; Geis NA; Kauczor HU; Bryant M; Chorianopoulos E; Pleger ST; Mereles D; Katus HA; Korosoglou G
    J Invasive Cardiol; 2015 Mar; 27(3):172-80. PubMed ID: 25740972
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Predictors for Paravalvular Regurgitation After TAVR With the Self-Expanding Prosthesis: Quantitative Measurement of MDCT Analysis.
    Yoon SH; Ahn JM; Ohno Y; Barbanti M; Chan J; Lin MS; Kim YH; Yang DH; Sugiyama D; Chan KT; Immé S; Tamburino CI; Sgroi C; Park DW; Kang SJ; Lee SW; Lee CW; Park SW; Lee M; Kao HL; Tamburino C; Park SJ
    JACC Cardiovasc Imaging; 2016 Oct; 9(10):1233-1234. PubMed ID: 26777220
    [No Abstract]   [Full Text] [Related]  

  • 14. 3D printing of the aortic annulus based on cardiovascular computed tomography: Preliminary experience in pre-procedural planning for aortic valve sizing.
    Faletti R; Gatti M; Cosentino A; Bergamasco L; Cura Stura E; Garabello D; Pennisi G; Salizzoni S; Veglia S; Ottavio D; Rinaldi M; Fonio P
    J Cardiovasc Comput Tomogr; 2018; 12(5):391-397. PubMed ID: 29857953
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Impact of Aortic Root Anatomy and Geometry on Paravalvular Leak in Transcatheter Aortic Valve Replacement With Extremely Large Annuli Using the Edwards SAPIEN 3 Valve.
    Tang GHL; Zaid S; George I; Khalique OK; Abramowitz Y; Maeno Y; Makkar RR; Jilaihawi H; Kamioka N; Thourani VH; Babaliaros V; Webb JG; Htun NM; Attinger-Toller A; Ahmad H; Kaple R; Sharma K; Kozina JA; Kaneko T; Shah P; Hirji SA; Desai ND; Anwaruddin S; Jagasia D; Herrmann HC; Basra SS; Szerlip MA; Mack MJ; Mathur M; Tan CW; Don CW; Sharma R; Gafoor S; Zhang M; Kapadia SR; Mick SL; Krishnaswamy A; Amoroso N; Salemi A; Wong SC; Kini AS; Rodés-Cabau J; Leon MB; Kodali SK
    JACC Cardiovasc Interv; 2018 Jul; 11(14):1377-1387. PubMed ID: 29960755
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Three Generations of Self-Expanding Transcatheter Aortic Valves: A Report From the STS/ACC TVT Registry.
    Forrest JK; Kaple RK; Tang GHL; Yakubov SJ; Nazif TM; Williams MR; Zhang A; Popma JJ; Reardon MJ
    JACC Cardiovasc Interv; 2020 Jan; 13(2):170-179. PubMed ID: 31973793
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The ACURATE neo Transcatheter Heart Valve: A Comprehensive Analysis of Predictors of Procedural Outcome.
    Kim WK; Möllmann H; Liebetrau C; Renker M; Rolf A; Simon P; Van Linden A; Arsalan M; Doss M; Hamm CW; Walther T
    JACC Cardiovasc Interv; 2018 Sep; 11(17):1721-1729. PubMed ID: 29803694
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Risk factors for paravalvular leak after transcatheter aortic valve replacement.
    Pollari F; Dell'Aquila AM; Söhn C; Marianowicz J; Wiehofsky P; Schwab J; Pauschinger M; Hitzl W; Fischlein T; Pfeiffer S
    J Thorac Cardiovasc Surg; 2019 Apr; 157(4):1406-1415.e3. PubMed ID: 30482527
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comprehensive Echocardiographic Assessment of Normal Transcatheter Valve Function.
    Hahn RT; Leipsic J; Douglas PS; Jaber WA; Weissman NJ; Pibarot P; Blanke P; Oh JK
    JACC Cardiovasc Imaging; 2019 Jan; 12(1):25-34. PubMed ID: 29909110
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Do CTA measurements of annular diameter, perimeter and area result in different TAVI prosthesis sizes?
    Horehledova B; Mihl C; Hendriks BMF; Eijsvoogel NG; Vainer J; Veenstra LF; Wildberger JE; Das M
    Int J Cardiovasc Imaging; 2018 Nov; 34(11):1819-1829. PubMed ID: 29909590
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 56.