These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

202 related articles for article (PubMed ID: 30327387)

  • 1. A new method to statistically describe microcatheter tip position in patient-specific aneurysm models.
    Nawka MT; Buhk JH; Gellissen S; Sedlacik J; Fiehler J; Frölich AM
    J Neurointerv Surg; 2019 Apr; 11(4):425-430. PubMed ID: 30327387
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Microcatheter Looping to Facilitate Aneurysm Selection in Coil Embolization of Paraclinoid Aneurysms.
    Cho YD; Rhim JK; Park JJ; Jeon JS; Yoo RE; Kang HS; Kim JE; Cho WS; Han MH
    Korean J Radiol; 2015; 16(4):899-905. PubMed ID: 26175591
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Technique for shaping microcatheter tips in coil embolization of paraclinoid aneurysms using full-scale volume rendering images of 3D rotational angiography.
    Toyota S; Fujimoto Y; Iwamoto F; Wakayama A; Yoshimine T
    Minim Invasive Neurosurg; 2009 Aug; 52(4):201-3. PubMed ID: 19838977
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A novel approach involving a microcatheter tip during aneurysmal coil embolization: The Γ (gamma) tip method.
    Ohshima T; Miyachi S; Matsuo N; Kawaguchi R; Maejima R; Takayasu M
    Interv Neuroradiol; 2019 Dec; 25(6):681-684. PubMed ID: 31271078
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Ascent™: a novel balloon microcatheter device used as the primary coiling microcatheter of a basilar tip aneurysm.
    Kirmani JF; Paolucci U
    J Neuroimaging; 2012 Apr; 22(2):191-3. PubMed ID: 21707825
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Microcatheter shaping using three-dimensional printed models for intracranial aneurysm coiling.
    Xu Y; Tian W; Wei Z; Li Y; Gao X; Li W; Dong B
    J Neurointerv Surg; 2020 Mar; 12(3):308-310. PubMed ID: 31563890
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Detection of the microcatheter tip using a novel microguidewire during coil embolization of cerebral aneurysms - technical note - .
    Toyota S; Ohara N; Iwamoto F; Wakayama A; Yoshimine T
    Neurol Med Chir (Tokyo); 2011; 51(4):330-2. PubMed ID: 21515961
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Tailor-made shaping of microcatheters using three-dimensional printed vessel models for endovascular coil embolization.
    Ishibashi T; Takao H; Suzuki T; Yuki I; Kaku S; Kan I; Nishimura K; Suzuki T; Watanabe M; Karagiozov K; Murayama Y
    Comput Biol Med; 2016 Oct; 77():59-63. PubMed ID: 27521515
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Microcatheter shaping using intravascular placement during intracranial aneurysm coiling.
    Yamaguchi S; Ito O; Koyanagi Y; Iwaki K; Matsukado K
    Interv Neuroradiol; 2017 Jun; 23(3):249-254. PubMed ID: 28166669
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Distal-tip shape-consistency testing of steam-shaped microcatheters suitable for cerebral aneurysm coil placement.
    Abe T; Hirohata M; Tanaka N; Uchiyama Y; Fujimoto K; Fujimura N; Norbash AM; Hayabuchi N
    AJNR Am J Neuroradiol; 2004; 25(6):1058-61. PubMed ID: 15205148
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The 'one and a half round microcatheterization technique' for stent-assisted coil embolization of intracranial aneurysm: technical case series.
    Miyachi S; Matsubara N; Izumi T; Asai T; Yamanouchi T; Ota K; Oda K; Wakabayashi T
    J Neurointerv Surg; 2014 Jun; 6(5):357-62. PubMed ID: 23723289
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Utilization of the Navien distal intracranial catheter in 78 cases of anterior circulation aneurysm treatment with the Pipeline embolization device.
    Colby GP; Lin LM; Huang J; Tamargo RJ; Coon AL
    J Neurointerv Surg; 2013 Nov; 5 Suppl 3():iii16-21. PubMed ID: 23516269
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Aneurysmography for visualizing large aneurysms.
    Kurata A; Miyasaka Y; Yada K; Kan S
    Neurosurgery; 1994 Apr; 34(4):745-7; discussion 747-8. PubMed ID: 8008178
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A new endovascular technique for small anterior choroidal artery aneurysms. A consecutive series using the 3-catheter-protective technique.
    Gimonet H; Desal HA; Mosimann PJ; Stracke P; Daumas-Duport B; Lintia-Gaultier A; Bourcier R; Chapot R
    J Neuroradiol; 2016 Jun; 43(3):223-6. PubMed ID: 27055375
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Marker alignment for Guglielmi detachable coil embolization: practical considerations.
    Kwon OK; Han MH
    AJNR Am J Neuroradiol; 2002 Sep; 23(8):1276-83. PubMed ID: 12223365
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Use of Triple Microcatheters for Endovascular Treatment of Wide-Necked Intracranial Aneurysms: A Single Center Experience.
    Cho YD; Rhim JK; Kang HS; Park JJ; Jeon JP; Kim JE; Cho WS; Han MH
    Korean J Radiol; 2015; 16(5):1109-18. PubMed ID: 26356992
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Modified balloon assisted coil embolization for the treatment of intracranial and cervical arterial aneurysms using coaxial dual lumen balloon microcatheters: initial experience.
    Jagadeesan BD; Siddiq F; Grande AW; Tummala RP
    J Neurointerv Surg; 2014 Nov; 6(9):704-7. PubMed ID: 24153339
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Embolization of wide-necked aneurysms with using three or more microcatheters.
    Kwon OK; Kim SH; Oh CW; Han MH; Kang HS; Kwon BJ; Kim JH; Han DH
    Acta Neurochir (Wien); 2006 Nov; 148(11):1139-45; discussion 1145. PubMed ID: 16990989
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Use of the 0.027-inch VIA microcatheter for delivery of Pipeline Flex: a technical note.
    Lin LM; Colby GP; Bender MT; Xu R; Huang J; Tamargo RJ; Coon AL
    J Neurointerv Surg; 2017 Jul; 9(7):689-693. PubMed ID: 28151413
    [TBL] [Abstract][Full Text] [Related]  

  • 20. <Editors' Choice> Initial experience with in vivo "endovascular shaping" technique that utilizes the vascular configuration for small cerebral aneurysm coiling.
    Hanaoka Y; Koyama JI; Yamazaki D; Miyaoka Y; Fujii Y; Nakamura T; Ogiwara T; Ito K; Horiuchi T
    Nagoya J Med Sci; 2020 May; 82(2):355-362. PubMed ID: 32581414
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.