These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

227 related articles for article (PubMed ID: 30357925)

  • 21. Ternary encoded super-selective arterial spin labeling for time-resolved flow territory mapping.
    Lindner T; Jansen O; Helle M
    Phys Med Biol; 2020 May; 65(10):10NT01. PubMed ID: 32160593
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Non-invasive visualization of collateral blood flow patterns of the circle of Willis by dynamic MR angiography.
    van Osch MJ; Hendrikse J; Golay X; Bakker CJ; van der Grond J
    Med Image Anal; 2006 Feb; 10(1):59-70. PubMed ID: 15950521
    [TBL] [Abstract][Full Text] [Related]  

  • 23. On the ability to exploit signal fluctuations in pseudocontinuous arterial spin labeling for inferring the major flow territories from a traditional perfusion scan.
    van Harten TW; Dzyubachyk O; Bokkers RPH; Wermer MJH; van Osch MJP
    Neuroimage; 2021 Apr; 230():117813. PubMed ID: 33524582
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Noncontrast-enhanced time-resolved 4D dynamic intracranial MR angiography at 7T: A feasibility study.
    Cong F; Zhuo Y; Yu S; Zhang X; Miao X; An J; Wang S; Cao Y; Zhang Y; Song HK; Wang DJ; Yan L
    J Magn Reson Imaging; 2018 Jul; 48(1):111-120. PubMed ID: 29232026
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Temporal and Spatial Variances in Arterial Spin-Labeling Are Inversely Related to Large-Artery Blood Velocity.
    Robertson AD; Matta G; Basile VS; Black SE; Macgowan CK; Detre JA; MacIntosh BJ
    AJNR Am J Neuroradiol; 2017 Aug; 38(8):1555-1561. PubMed ID: 28619834
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Perfusion territory imaging of intracranial branching arteries - optimization of continuous artery-selective spin labeling (CASSL).
    Helle M; Rüfer S; Alfke K; Jansen O; Norris DG
    NMR Biomed; 2011 May; 24(4):404-12. PubMed ID: 22945292
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Superselective pseudo-continuous arterial spin labeling angiography.
    Jensen-Kondering U; Lindner T; van Osch MJ; Rohr A; Jansen O; Helle M
    Eur J Radiol; 2015 Sep; 84(9):1758-67. PubMed ID: 26113163
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A general framework for the analysis of vessel encoded arterial spin labeling for vascular territory mapping.
    Chappell MA; Okell TW; Jezzard P; Woolrich MW
    Magn Reson Med; 2010 Nov; 64(5):1529-39. PubMed ID: 20677231
    [TBL] [Abstract][Full Text] [Related]  

  • 29. MR Imaging of Individual Perfusion Reorganization Using Superselective Pseudocontinuous Arterial Spin-Labeling in Patients with Complex Extracranial Steno-Occlusive Disease.
    Richter V; Helle M; van Osch MJ; Lindner T; Gersing AS; Tsantilas P; Eckstein HH; Preibisch C; Zimmer C
    AJNR Am J Neuroradiol; 2017 Apr; 38(4):703-711. PubMed ID: 28183839
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Accelerated 3D-GRASE imaging improves quantitative multiple post labeling delay arterial spin labeling.
    Boland M; Stirnberg R; Pracht ED; Kramme J; Viviani R; Stingl J; Stöcker T
    Magn Reson Med; 2018 Dec; 80(6):2475-2484. PubMed ID: 29770492
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Superselective pseudocontinuous arterial spin labeling.
    Helle M; Norris DG; Rüfer S; Alfke K; Jansen O; van Osch MJ
    Magn Reson Med; 2010 Sep; 64(3):777-86. PubMed ID: 20597127
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A kinetic model for vessel-encoded dynamic angiography with arterial spin labeling.
    Okell TW; Chappell MA; Schulz UG; Jezzard P
    Magn Reson Med; 2012 Sep; 68(3):969-79. PubMed ID: 22246669
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Simultaneous acquisition of perfusion image and dynamic MR angiography using time-encoded pseudo-continuous ASL.
    Suzuki Y; Helle M; Koken P; Van Cauteren M; van Osch MJP
    Magn Reson Med; 2018 May; 79(5):2676-2684. PubMed ID: 28913838
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Pseudo-asymmetry of cerebral blood flow in arterial spin labeling caused by unilateral fetal-type circle of Willis: Technical limitation or a way to better understanding physiological variations of cerebral perfusion and improving arterial spin labeling acquisition?
    Law-Ye B; Geerts B; Galanaud D; Dormont D; Pyatigorskaya N
    J Cereb Blood Flow Metab; 2016 Sep; 36(9):1641-3. PubMed ID: 27256322
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Vessel-encoded dynamic magnetic resonance angiography using arterial spin labeling.
    Okell TW; Chappell MA; Woolrich MW; Günther M; Feinberg DA; Jezzard P
    Magn Reson Med; 2010 Aug; 64(2):430-8. PubMed ID: 20665787
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Determining the optimal postlabeling delay for arterial spin labeling using subject-specific estimates of blood velocity in the carotid artery.
    Gai ND; Butman JA
    J Magn Reson Imaging; 2019 Sep; 50(3):951-960. PubMed ID: 30681220
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Practical considerations for territorial perfusion mapping in the cerebral circulation using super-selective pseudo-continuous arterial spin labeling.
    Schollenberger J; Figueroa CA; Nielsen JF; Hernandez-Garcia L
    Magn Reson Med; 2020 Feb; 83(2):492-504. PubMed ID: 31418475
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Vessel-selective, non-contrast enhanced, time-resolved MR angiography with vessel-selective arterial spin labeling technique (CINEMA-SELECT) in intracranial arteries.
    Nakamura M; Yoneyama M; Tabuchi T; Takemura A; Obara M; Tatsuno S; Sawano S
    Radiol Phys Technol; 2013 Jul; 6(2):327-34. PubMed ID: 23475783
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Intravascular signal suppression and microvascular signal mapping using delays alternating with nutation for tailored excitation (DANTE) pulse for arterial spin labeling perfusion imaging.
    Fujiwara Y; Kimura H; Ishida S; Kanamoto M; Takei N; Matsuda T; Kosaka N; Adachi T
    MAGMA; 2020 Jun; 33(3):367-376. PubMed ID: 31625029
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Validation of planning-free vessel-encoded pseudo-continuous arterial spin labeling MR imaging as territorial-ASL strategy by comparison to super-selective p-CASL MRI.
    Hartkamp NS; Helle M; Chappell MA; Okell TW; Hendrikse J; Bokkers RP; van Osch MJ
    Magn Reson Med; 2014 Jun; 71(6):2059-70. PubMed ID: 23878062
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.