143 related articles for article (PubMed ID: 30358036)
1. Valve-Enabled Sample Preparation and RNA Amplification in a Coffee Mug for Zika Virus Detection.
Jiang X; Loeb JC; Manzanas C; Lednicky JA; Fan ZH
Angew Chem Int Ed Engl; 2018 Dec; 57(52):17211-17214. PubMed ID: 30358036
[TBL] [Abstract][Full Text] [Related]
2. Rapid colorimetric detection of Zika virus from serum and urine specimens by reverse transcription loop-mediated isothermal amplification (RT-LAMP).
Calvert AE; Biggerstaff BJ; Tanner NA; Lauterbach M; Lanciotti RS
PLoS One; 2017; 12(9):e0185340. PubMed ID: 28945787
[TBL] [Abstract][Full Text] [Related]
3. Detection of Zika virus using reverse-transcription LAMP coupled with reverse dot blot analysis in saliva.
Sabalza M; Yasmin R; Barber CA; Castro T; Malamud D; Kim BJ; Zhu H; Montagna RA; Abrams WR
PLoS One; 2018; 13(2):e0192398. PubMed ID: 29401479
[TBL] [Abstract][Full Text] [Related]
4. Detection of Zika Virus Using Reverse Transcription-Loop-Mediated Isothermal Amplification (RT-LAMP).
Lamb LE; Bartolone SN; Chancellor MB
Methods Mol Biol; 2020; 2142():137-146. PubMed ID: 32367365
[TBL] [Abstract][Full Text] [Related]
5. Development and validation of a one-step reverse transcription loop-mediated isothermal amplification (RT-LAMP) for rapid detection of ZIKV in patient samples from Brazil.
da Silva SJR; Pardee K; Balasuriya UBR; Pena L
Sci Rep; 2021 Feb; 11(1):4111. PubMed ID: 33602985
[TBL] [Abstract][Full Text] [Related]
6. A Valve-Enabled Sample Preparation Device with Isothermal Amplification for Multiplexed Virus Detection at the Point-of-Care.
Manzanas C; Alam MM; Loeb JC; Lednicky JA; Wu CY; Fan ZH
ACS Sens; 2021 Nov; 6(11):4176-4184. PubMed ID: 34767357
[TBL] [Abstract][Full Text] [Related]
7. Point of sampling detection of Zika virus within a multiplexed kit capable of detecting dengue and chikungunya.
Yaren O; Alto BW; Gangodkar PV; Ranade SR; Patil KN; Bradley KM; Yang Z; Phadke N; Benner SA
BMC Infect Dis; 2017 Apr; 17(1):293. PubMed ID: 28427352
[TBL] [Abstract][Full Text] [Related]
8. Development and Validation of Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) for Rapid Detection of ZIKV in Mosquito Samples from Brazil.
Silva SJRD; Paiva MHS; Guedes DRD; Krokovsky L; Melo FL; Silva MALD; Silva AD; Ayres CFJ; Pena LJ
Sci Rep; 2019 Mar; 9(1):4494. PubMed ID: 30872672
[TBL] [Abstract][Full Text] [Related]
9. Rapid and sensitive detection of Zika virus by reverse transcription loop-mediated isothermal amplification.
Wang X; Yin F; Bi Y; Cheng G; Li J; Hou L; Li Y; Yang B; Liu W; Yang L
J Virol Methods; 2016 Dec; 238():86-93. PubMed ID: 27793644
[TBL] [Abstract][Full Text] [Related]
10. Loop-Mediated Isothermal Amplification (LAMP) for the Diagnosis of Zika Virus: A Review.
Silva SJRD; Pardee K; Pena L
Viruses; 2019 Dec; 12(1):. PubMed ID: 31877989
[TBL] [Abstract][Full Text] [Related]
11. Reverse Transcription-Loop-mediated Isothermal Amplification (RT-LAMP) Assay for Zika Virus and Housekeeping Genes in Urine, Serum, and Mosquito Samples.
Bartolone SN; Tree MO; Conway MJ; Chancellor MB; Lamb LE
J Vis Exp; 2018 Sep; (139):. PubMed ID: 30272674
[TBL] [Abstract][Full Text] [Related]
12. Development of Universal and Lineage-Specific Primer Sets for Rapid Detection of the Zika Virus (ZIKV) in Blood and Urine Samples Using One-Step Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP).
Bui TT; Moi ML; Morita K; Hasebe F
Jpn J Infect Dis; 2020 Mar; 73(2):153-156. PubMed ID: 31666491
[TBL] [Abstract][Full Text] [Related]
13. Mayaro virus detection by integrating sample preparation with isothermal amplification in portable devices.
Alipanah M; Manzanas C; Hai X; Lednicky JA; Paniz-Mondolfi A; Morris JG; Fan ZH
Anal Bioanal Chem; 2023 Sep; 415(23):5605-5617. PubMed ID: 37470813
[TBL] [Abstract][Full Text] [Related]
14. Instrument-Free Point-of-Care Molecular Detection of Zika Virus.
Song J; Mauk MG; Hackett BA; Cherry S; Bau HH; Liu C
Anal Chem; 2016 Jul; 88(14):7289-94. PubMed ID: 27306491
[TBL] [Abstract][Full Text] [Related]
15. Simple and Highly Sensitive Molecular Diagnosis of Zika Virus by Lateral Flow Assays.
Lee D; Shin Y; Chung S; Hwang KS; Yoon DS; Lee JH
Anal Chem; 2016 Dec; 88(24):12272-12278. PubMed ID: 28193014
[TBL] [Abstract][Full Text] [Related]
16. Ten-minute direct detection of Zika virus in serum samples by RT-LAMP.
Estrela PFN; Mendes GM; de Oliveira KG; Bailão AM; Soares CMA; Assunção NA; Duarte GRM
J Virol Methods; 2019 Sep; 271():113675. PubMed ID: 31170469
[TBL] [Abstract][Full Text] [Related]
17. Development and evaluation of a visible reverse transcription-loop-mediated isothermal amplification (RT-LAMP) for the detection of Asian lineage ZIKV in field-caught mosquitoes.
Siriyasatien P; Wacharapluesadee S; Kraivichian K; Suwanbamrung C; Sutthanont N; Cantos-Barreda A; Phumee A
Acta Trop; 2022 Dec; 236():106691. PubMed ID: 36103950
[TBL] [Abstract][Full Text] [Related]
18. Point-of-care diagnostic assay for the detection of Zika virus using the recombinase polymerase amplification method.
Vasileva Wand NI; Bonney LC; Watson RJ; Graham V; Hewson R
J Gen Virol; 2018 Aug; 99(8):1012-1026. PubMed ID: 29897329
[TBL] [Abstract][Full Text] [Related]
19. Rapid Detection of Zika Virus in Urine Samples and Infected Mosquitos by Reverse Transcription-Loop-Mediated Isothermal Amplification.
Lamb LE; Bartolone SN; Tree MO; Conway MJ; Rossignol J; Smith CP; Chancellor MB
Sci Rep; 2018 Feb; 8(1):3803. PubMed ID: 29491389
[TBL] [Abstract][Full Text] [Related]
20. A smartphone-based diagnostic platform for rapid detection of Zika, chikungunya, and dengue viruses.
Priye A; Bird SW; Light YK; Ball CS; Negrete OA; Meagher RJ
Sci Rep; 2017 Mar; 7():44778. PubMed ID: 28317856
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]