137 related articles for article (PubMed ID: 30359512)
1. Micro Gas Chromatography: An Overview of Critical Components and Their Integration.
Regmi BP; Agah M
Anal Chem; 2018 Nov; 90(22):13133-13150. PubMed ID: 30359512
[TBL] [Abstract][Full Text] [Related]
2. Pore size effect of mesoporous silica stationary phase on the separation performance of microfabricated gas chromatography columns.
Hou L; Feng F; You W; Xu P; Luo F; Tian B; Zhou H; Li X
J Chromatogr A; 2018 Jun; 1552():73-78. PubMed ID: 29665976
[TBL] [Abstract][Full Text] [Related]
3. [Research progress of micro-electro-mechanical systems micro gas chromatography columns].
Luo F; Feng F; Zhao B; Tian B; Yang X; Zhou H; Li X
Se Pu; 2018 Aug; 36(8):707-715. PubMed ID: 30251492
[TBL] [Abstract][Full Text] [Related]
4. Demonstration of motionless Knudsen pump based micro-gas chromatography featuring micro-fabricated columns and on-column detectors.
Liu J; Gupta NK; Wise KD; Gianchandani YB; Fan X
Lab Chip; 2011 Oct; 11(20):3487-92. PubMed ID: 21869988
[TBL] [Abstract][Full Text] [Related]
5. Axial thermal gradients in microchip gas chromatography.
Wang A; Hynynen S; Hawkins AR; Tolley SE; Tolley HD; Lee ML
J Chromatogr A; 2014 Dec; 1374():216-223. PubMed ID: 25476685
[TBL] [Abstract][Full Text] [Related]
6. Metal-Organic Framework Stationary Phases for One- and Two-Dimensional Micro-Gas Chromatographic Separations of Light Alkanes and Polar Toxic Industrial Chemicals.
Read DH; Sillerud CH; Whiting JJ; Achyuthan KE
J Chromatogr Sci; 2020 Apr; 58(5):389-400. PubMed ID: 32291439
[TBL] [Abstract][Full Text] [Related]
7. Smart multi-channel two-dimensional micro-gas chromatography for rapid workplace hazardous volatile organic compounds measurement.
Liu J; Seo JH; Li Y; Chen D; Kurabayashi K; Fan X
Lab Chip; 2013 Mar; 13(5):818-25. PubMed ID: 23303462
[TBL] [Abstract][Full Text] [Related]
8. Control Software Design for a Multisensing Multicellular Microscale Gas Chromatography System.
Xu Q; Zhao X; Qin Y; Gianchandani YB
Micromachines (Basel); 2023 Dec; 15(1):. PubMed ID: 38258214
[TBL] [Abstract][Full Text] [Related]
9. A monolithically-integrated μGC chemical sensor system.
Manginell RP; Bauer JM; Moorman MW; Sanchez LJ; Anderson JM; Whiting JJ; Porter DA; Copic D; Achyuthan KE
Sensors (Basel); 2011; 11(7):6517-32. PubMed ID: 22163970
[TBL] [Abstract][Full Text] [Related]
10. Microchip gas chromatography column using magnetic beads coated with polydimethylsiloxane and metal organic frameworks.
Sun X; Shi J; Men X; Li Y; Qu H; Chang Y; Hu J; Yan X; Guo W; Sun C; Duan X
J Chromatogr A; 2023 Aug; 1705():464188. PubMed ID: 37423078
[TBL] [Abstract][Full Text] [Related]
11. Ultrafast gas chromatography on single-wall carbon nanotube stationary phases in microfabricated channels.
Stadermann M; McBrady AD; Dick B; Reid VR; Noy A; Synovec RE; Bakajin O
Anal Chem; 2006 Aug; 78(16):5639-44. PubMed ID: 16906706
[TBL] [Abstract][Full Text] [Related]
12. Portable comprehensive two-dimensional micro-gas chromatography using an integrated flow-restricted pneumatic modulator.
Huang X; Li MW; Zang W; Huang X; Sivakumar AD; Sharma R; Fan X
Microsyst Nanoeng; 2022; 8():115. PubMed ID: 36329696
[TBL] [Abstract][Full Text] [Related]
13. A fully electronic microfabricated gas chromatograph with complementary capacitive detectors for indoor pollutants.
Qin Y; Gianchandani YB
Microsyst Nanoeng; 2016; 2():15049. PubMed ID: 31057813
[TBL] [Abstract][Full Text] [Related]
14. Improved micromachined column design and fluidic interconnects for programmed high-temperature gas chromatography separations.
Gaddes D; Westland J; Dorman FL; Tadigadapa S
J Chromatogr A; 2014 Jul; 1349():96-104. PubMed ID: 24866564
[TBL] [Abstract][Full Text] [Related]
15. Review on Micro-Gas Analyzer Systems: Feasibility, Separations and Applications.
Lussac E; Barattin R; Cardinael P; Agasse V
Crit Rev Anal Chem; 2016 Nov; 46(6):455-68. PubMed ID: 26908000
[TBL] [Abstract][Full Text] [Related]
16. Toward a microfabricated preconcentrator-focuser for a wearable micro-scale gas chromatograph.
Bryant-Genevier J; Zellers ET
J Chromatogr A; 2015 Nov; 1422():299-309. PubMed ID: 26530144
[TBL] [Abstract][Full Text] [Related]
17. Fabrication and characterization of microelectromechanical systems-based gas chromatography column with embedded micro-posts for separation of environmental carcinogens.
Sun J; Cui D; Chen X; Zhang L; Cai H; Li H
J Chromatogr A; 2013 May; 1291():122-8. PubMed ID: 23601549
[TBL] [Abstract][Full Text] [Related]
18. On-column micro gas chromatography detection with capillary-based optical ring resonators.
Shopova SI; White IM; Sun Y; Zhu H; Fan X; Frye-Mason G; Thompson A; Ja SJ
Anal Chem; 2008 Mar; 80(6):2232-8. PubMed ID: 18271605
[TBL] [Abstract][Full Text] [Related]
19. A micro gas chromatographic column with embedded elliptic cylindrical posts.
Tian B; Zhao B; Feng F; Luo F; Zhou H; Ge X; Yanhong W; Li X
J Chromatogr A; 2018 Aug; 1565():130-137. PubMed ID: 29941198
[TBL] [Abstract][Full Text] [Related]
20. μGC × μGC: comprehensive two-dimensional gas chromatographic separations with microfabricated components.
Collin WR; Bondy A; Paul D; Kurabayashi K; Zellers ET
Anal Chem; 2015 Feb; 87(3):1630-7. PubMed ID: 25535845
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]