These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

209 related articles for article (PubMed ID: 30361757)

  • 1. Uncemented or cemented femoral components work equally well in total knee arthroplasty.
    Henricson A; Wojtowicz R; Nilsson KG; Crnalic S
    Knee Surg Sports Traumatol Arthrosc; 2019 Apr; 27(4):1251-1258. PubMed ID: 30361757
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Cemented versus uncemented fixation of the femoral component of the NexGen CR total knee replacement in patients younger than 60 years: a prospective randomised controlled RSA study.
    Gao F; Henricson A; Nilsson KG
    Knee; 2009 Jun; 16(3):200-6. PubMed ID: 19097910
    [TBL] [Abstract][Full Text] [Related]  

  • 3. No Difference in Implant Micromotion Between Hybrid Fixation and Fully Cemented Revision Total Knee Arthroplasty: A Randomized Controlled Trial with Radiostereometric Analysis of Patients with Mild-to-Moderate Bone Loss.
    Heesterbeek PJ; Wymenga AB; van Hellemondt GG
    J Bone Joint Surg Am; 2016 Aug; 98(16):1359-69. PubMed ID: 27535438
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fixation and clinical outcome of uncemented peri-apatite-coated
    van Hamersveld KT; Marang-van de Mheen PJ; Tsonaka R; Valstar ER; Toksvig-Larsen S
    Bone Joint J; 2017 Nov; 99-B(11):1467-1476. PubMed ID: 29092985
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Uncemented monoblock trabecular metal posterior stabilized high-flex total knee arthroplasty: similar pattern of migration to the cruciate-retaining design - a prospective radiostereometric analysis (RSA) and clinical evaluation of 40 patients (49 knees) 60 years or younger with 9 years' follow-up.
    Wojtowicz R; Henricson A; Nilsson KG; Crnalic S
    Acta Orthop; 2019 Oct; 90(5):460-466. PubMed ID: 31210081
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparable Stability of Cemented vs Press-Fit Placed Stems in Revision Total Knee Arthroplasty With Mild to Moderate Bone Loss: 6.5-Year Results From a Randomized Controlled Trial With Radiostereometric Analysis.
    Kosse NM; van Hellemondt GG; Wymenga AB; Heesterbeek PJ
    J Arthroplasty; 2017 Jan; 32(1):197-201. PubMed ID: 27554783
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Equivalent 2-year stabilization of uncemented tibial component migration despite higher early migration compared with cemented fixation: an RSA study on 360 total knee arthroplasties.
    Laende EK; Astephen Wilson JL; Mills Flemming J; Valstar ER; Richardson CG; Dunbar MJ
    Acta Orthop; 2019 Apr; 90(2):172-178. PubMed ID: 30669909
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The Influence of Postoperative Coronal Alignment on Tibial Migration After Total Knee Arthroplasty in Preoperative Varus and Valgus Knees: A Secondary Analysis of 10 Randomized Controlled Trials Using Radiostereometric Analysis.
    Hasan S; Kaptein BL; Nelissen RGHH; van Hamersveld KT; Toksvig-Larsen S; Marang-van de Mheen PJ
    J Bone Joint Surg Am; 2021 Dec; 103(24):2281-2290. PubMed ID: 34648477
    [TBL] [Abstract][Full Text] [Related]  

  • 9. What is the role of cemented fixation in total knee arthroplasty? The two-year results of a randomized RSA controlled trial.
    van Ooij B; Sierevelt IN; van der Vis HM; Hoornenborg D; Haverkamp D
    Bone Joint J; 2021 Jan; 103-B(1):98-104. PubMed ID: 33380179
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effect of tourniquet use on fixation quality in cemented total knee arthroplasty a prospective randomized clinical controlled RSA trial.
    Molt M; Harsten A; Toksvig-Larsen S
    Knee; 2014 Mar; 21(2):396-401. PubMed ID: 24238650
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The associations of implant and patient factors with migration of the tibial component differ by sex : a radiostereometric study on more than 400 total knee arthroplasties.
    Laende EK; Mills Flemming J; Astephen Wilson JL; Cantoni E; Dunbar MJ
    Bone Joint J; 2022 Apr; 104-B(4):444-451. PubMed ID: 35360938
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The assessment of the stability of the tibial component of a novel knee arthroplasty system using radiostereometric analysis.
    Turgeon TR; Gascoyne TC; Laende EK; Dunbar MJ; Bohm ER; Richardson CG
    Bone Joint J; 2018 Dec; 100-B(12):1579-1584. PubMed ID: 30499327
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Predictive value of short-term migration in determining long-term stable fixation in cemented and cementless total knee arthroplasties.
    Laende EK; Richardson CG; Dunbar MJ
    Bone Joint J; 2019 Jul; 101-B(7_Supple_C):55-60. PubMed ID: 31256645
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The beneficial effect of hydroxyapatite lasts: a randomized radiostereometric trial comparing hydroxyapatite-coated, uncoated, and cemented tibial components for up to 16 years.
    Pijls BG; Valstar ER; Kaptein BL; Fiocco M; Nelissen RG
    Acta Orthop; 2012 Apr; 83(2):135-41. PubMed ID: 22329667
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Prospective results of uncemented tantalum monoblock tibia in total knee arthroplasty: minimum 5-year follow-up in patients younger than 55 years.
    Kamath AF; Lee GC; Sheth NP; Nelson CL; Garino JP; Israelite CL
    J Arthroplasty; 2011 Dec; 26(8):1390-5. PubMed ID: 21872424
    [TBL] [Abstract][Full Text] [Related]  

  • 16. No difference in terms of radiostereometric analysis between fixed- and mobile-bearing total knee arthroplasty: a randomized, single-blind, controlled trial.
    Schotanus MGM; Pilot P; Kaptein BL; Draijer WF; Tilman PBJ; Vos R; Kort NP
    Knee Surg Sports Traumatol Arthrosc; 2017 Sep; 25(9):2978-2985. PubMed ID: 27120194
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Is There a Difference between Cemented and Uncemented Femoral Stem Extensions in Revision Knee Arthroplasty?
    Lachiewicz PF; O'Dell JA
    J Knee Surg; 2020 Jan; 33(1):84-88. PubMed ID: 30562832
    [TBL] [Abstract][Full Text] [Related]  

  • 18. No difference in component migration at five years between the cemented cruciate-retaining ATTUNE and PFC-Sigma knee prosthesis: an update of a randomized clinical radiostereometry trial.
    YĆ¼ksel Y; Koster LA; Kaptein BL; Nelissen RGHH; den Hollander P
    Bone Joint J; 2023 Nov; 105-B(11):1168-1176. PubMed ID: 37907075
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Migration of a novel 3D-printed cementless versus a cemented total knee arthroplasty: two-year results of a randomized controlled trial using radiostereometric analysis.
    Hasan S; van Hamersveld KT; Marang-van de Mheen PJ; Kaptein BL; Nelissen RGHH; Toksvig-Larsen S
    Bone Joint J; 2020 Aug; 102-B(8):1016-1024. PubMed ID: 32731825
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Trabecular metal tibial knee component still stable at 10 years.
    Henricson A; Nilsson KG
    Acta Orthop; 2016 Oct; 87(5):504-10. PubMed ID: 27357222
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.