These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

180 related articles for article (PubMed ID: 30369172)

  • 21. Reliability of transthoracic echocardiography in estimating the size of Amplatzer septal occluder and guiding percutaneous closure of atrial septal defects.
    Li GS; Kong GM; Ji QS; Li JF; Chen YG; You BA; Zhang Y
    Chin Med J (Engl); 2008 Jun; 121(11):973-6. PubMed ID: 18706243
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Transcatheter interventional therapy of congenital heart disease: the results of Chinese TIT registry].
    Li JJ; Zhang ZW; Qian MY; Li YF; Wang SS;
    Zhonghua Xin Xue Guan Bing Za Zhi; 2012 Apr; 40(4):283-8. PubMed ID: 22801304
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Survival analysis of Down syndrome with congenital heart disease: a 5-years registry at QSNICH.
    Layangool T; Sangtawesin C; Kirawittaya T; Prompan W; Prachasilchai P; Pechdamrongsakul A
    J Med Assoc Thai; 2014 Jun; 97 Suppl 6():S108-14. PubMed ID: 25391181
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Application of perimembranous ventricular septal defects closure solely by femoral vein approach under transesophageal echocardiography guidance].
    Bu H; Gao L; Zhang W; Wu Q; Jin W; Tang M; Zhao T
    Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2017 Jul; 42(7):802-807. PubMed ID: 28845004
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Clinical results of large secundum atrial septal defect closure in adult using percutaneous transcatheter Cocoon atrial septal occluder.
    Lairakdomrong K; Srimahachota S; Lertsapcharoen P; Chaipromprasit J; Boonyaratavej S; Kaewsukkho P
    J Med Assoc Thai; 2013 Sep; 96(9):1127-34. PubMed ID: 24163987
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Amplatzer septal occluder closure of atrial septal defect: evaluation of transthoracic echocardiography, cardiac CT, and transesophageal echocardiography.
    Ko SF; Liang CD; Yip HK; Huang CC; Ng SH; Huang CF; Chen MC
    AJR Am J Roentgenol; 2009 Dec; 193(6):1522-9. PubMed ID: 19933643
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Preprocedural Transthoracic Echocardiography Can Predict Amplatzer Septal Occluder Device Size for Transcatheter Atrial Septal Defect Closure.
    Sah SP; Bartakian S; El-Said H; Molkara DP; Printz B; Moore JW
    Congenit Heart Dis; 2016 Dec; 11(6):656-662. PubMed ID: 27079542
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Feasibility of device closure for multiple atrial septal defects using 3D printing and ultrasound-guided intervention technique].
    Qiu X; Lü B; Xu N; Yan CW; Ouyang WB; Liu Y; Zhang FW; Yue ZQ; Pang KJ; Pan XB
    Zhonghua Yi Xue Za Zhi; 2017 Apr; 97(16):1214-1217. PubMed ID: 28441847
    [No Abstract]   [Full Text] [Related]  

  • 29. Non-fluoroscopic percutaneous transcatheter closure of atrial septal defects in children under transesophageal echocardiographic guidance.
    Xu WZ; Shou XY; Li JH; Yu JG; Zhang ZW; Yu J; Ye JJ
    World J Pediatr; 2018 Aug; 14(4):378-382. PubMed ID: 30141110
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Transthoracic echocardiography monitoring during atrial septal defect and ventricular septal defect device closures using a three-dimensional printed transducer holder.
    Jian WY; Lin SM; Tsai SK; Hwang B
    J Chin Med Assoc; 2021 May; 84(5):550-554. PubMed ID: 33770054
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Comparison of transthoracic or percutaneous balloon pulmonary valvuloplasty in the therapy of pulmonary valve stenosis].
    Xie YQ; Yan J; Hua ZD; Ouyang WB; Pang KJ; Zhang YB; Zhang GJ; Li SJ
    Zhonghua Wai Ke Za Zhi; 2017 Jun; 55(6):459-462. PubMed ID: 28592081
    [No Abstract]   [Full Text] [Related]  

  • 32. [Applying interventional treatment for the atrial septal defect in 165 children under five years of age].
    Wang HS; Qian MY; Zhang ZW; Zeng SY; Xie YM; Li YF
    Zhonghua Er Ke Za Zhi; 2005 May; 43(5):373-6. PubMed ID: 15924757
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Simultaneous transcatheter therapy for perimembranous ventricular septal defect combined with patent ductus arteriosus.
    Wang Q; Zhu X; Duanzhen Z; Zhang P; Chen H; Han X; Sheng X; Meng L
    J Card Surg; 2017 Jun; 32(6):370-375. PubMed ID: 28497553
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Complications of transcatheter interventional occlusion of ventricular septal defects].
    Zhang YS; Li H; Liu JP; Dai ZX; Wang L; Zhang J; Li J; Wang XY
    Zhonghua Er Ke Za Zhi; 2005 Jan; 43(1):35-8. PubMed ID: 15796806
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Initial clinical experience with the GORE
    de Hemptinne Q; Horlick EM; Osten MD; Millán X; Tadros VX; Pighi M; Gonzalez Barlatey F; Alnasser SM; Miró J; Asgar AW; Ibrahim R
    Catheter Cardiovasc Interv; 2017 Sep; 90(3):495-503. PubMed ID: 28128523
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Percutaneous closure of multiple atrial septal defects and patent ductus arteriosus during the same session.
    Odemiş E; Ozyılmaz I; Güzeltaş A
    Turk Kardiyol Dern Ars; 2012 Dec; 40(8):726-8. PubMed ID: 23518889
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Application research of percutaneous patent ductus arteriosus closure by femoral vein approach under echocardiography guidance].
    Wang S; Liu Y; Wang S; Ouyang W; Hu S; Li S; Zhang D; Zhang F; Pang K; Fang N; Pan X
    Zhonghua Yi Xue Za Zhi; 2015 Jul; 95(27):2183-5. PubMed ID: 26710908
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Safety and efficacy of transthoracic versus transesophageal echocardiography in transcatheter closure of atrial septal defects. Reporting a single center experience from Saudi Arabia.
    Azhar AS
    Saudi Med J; 2016 Nov; 37(11):1196-1205. PubMed ID: 27761557
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Quality of life in pregnancy after percutaneous closure of atrial septal defect guided by transthoracic echocardiography.
    Qiu ZH; Zong ZF; Wu QS; Xiao J; Chai TC; Chen XD; Shen Y; Chen LW
    BMC Cardiovasc Disord; 2022 Dec; 22(1):550. PubMed ID: 36528570
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The relation between atrial septal defect shape, diameter, and area using three-dimensional transoesophageal echocardiography and balloon sizing during percutaneous closure in children.
    Hascoet S; Hadeed K; Marchal P; Dulac Y; Alacoque X; Heitz F; Acar P
    Eur Heart J Cardiovasc Imaging; 2015 Jul; 16(7):747-55. PubMed ID: 25617028
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.