BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

285 related articles for article (PubMed ID: 30373958)

  • 1. Novel Cerebral Protection Technique During Right Transcarotid TAVR in Bicuspid Aortic Stenosis and Porcelain Aorta.
    Hiendlmayr B; McGuire KE; Curtis LE; Perucki WH; Gowani SA; Abdelaziz A; Hoover NE; Cheema M; Azemi T
    J Invasive Cardiol; 2018 Nov; 30(11):E129. PubMed ID: 30373958
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Cerebral Embolic Protection During Transcatheter Aortic Valve Replacement Significantly Reduces Death and Stroke Compared With Unprotected Procedures.
    Seeger J; Gonska B; Otto M; Rottbauer W; Wöhrle J
    JACC Cardiovasc Interv; 2017 Nov; 10(22):2297-2303. PubMed ID: 28917515
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Transcarotid transcatheter aortic valve replacement with cerebral embolic protection.
    McGrath D; Salehi P; Weintraub A; Zhan Y
    J Card Surg; 2022 Jun; 37(6):1779-1782. PubMed ID: 35301761
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Cerebral embolic protection systems for transcatheter aortic valve replacement.
    Gasior T; Mangner N; Bijoch J; Wojakowski W
    J Interv Cardiol; 2018 Dec; 31(6):891-898. PubMed ID: 30467892
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Complete filter-based cerebral embolic protection with transcatheter aortic valve replacement.
    Van Gils L; Kroon H; Daemen J; Ren C; Maugenest AM; Schipper M; De Jaegere PP; Van Mieghem NM
    Catheter Cardiovasc Interv; 2018 Mar; 91(4):790-797. PubMed ID: 28895285
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A Novel Transcarotid Approach for Implantation of Balloon-Expandable or Self-Expandable Transcatheter Aortic Valves.
    Campelo-Parada F; Rodés-Cabau J; Dumont E; Del Trigo M; Regueiro A; Doyle D; De Larochellière R; Paradis JM; Kalavrouziotis D; Mohammadi S
    Can J Cardiol; 2016 Dec; 32(12):1575.e9-1575.e12. PubMed ID: 27181189
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Protection from Cerebral Embolic Events During Transcatheter Aortic Valve Replacement.
    Rossow CF; McCabe JM
    Curr Cardiol Rep; 2016 Feb; 18(2):16. PubMed ID: 26768742
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Clinical Outcomes of Sentinel Cerebral Protection System Use During Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis.
    Ndunda PM; Vindhyal MR; Muutu TM; Fanari Z
    Cardiovasc Revasc Med; 2020 Jun; 21(6):717-722. PubMed ID: 31175048
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Rate of peri-procedural stroke observed with cerebral embolic protection during transcatheter aortic valve replacement: a patient-level propensity-matched analysis.
    Seeger J; Kapadia SR; Kodali S; Linke A; Wöhrle J; Haussig S; Makkar R; Mehran R; Rottbauer W; Leon M
    Eur Heart J; 2019 May; 40(17):1334-1340. PubMed ID: 30590554
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Transcarotid Transcatheter Aortic Valve Replacement: Feasibility and Safety.
    Mylotte D; Sudre A; Teiger E; Obadia JF; Lee M; Spence M; Khamis H; Al Nooryani A; Delhaye C; Amr G; Koussa M; Debry N; Piazza N; Modine T
    JACC Cardiovasc Interv; 2016 Mar; 9(5):472-80. PubMed ID: 26965937
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Early Experience With Embolic Protection Devices During Transcatheter Aortic Valve Replacement.
    Stamou SC; Polcari K; Abdallah A; James T; Rothenberg M; Daniel G; Nores MA
    J Invasive Cardiol; 2019 Oct; 31(10):296-299. PubMed ID: 31567113
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Impact of routine use of a cerebral protection device on the TAVR procedure and its short-term outcomes: a single-centre experience.
    von Kemp MJ; Floré V; Lau CW; De Sutter J; Provenier F; Cornelis K
    Acta Cardiol; 2022 Dec; 77(10):922-929. PubMed ID: 36044035
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Patient eligibility for application of a two-filter cerebral embolic protection device during transcatheter aortic valve implantation: does one size fit all?
    Voss S; Schechtl J; Nöbauer C; Bleiziffer S; Lange R
    Interact Cardiovasc Thorac Surg; 2020 Apr; 30(4):605-612. PubMed ID: 31904829
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cerebral Embolic Protection Devices for Transcatheter Aortic Valve Replacement: Review of the Literature and Future Perspectives.
    Ng S; Cunningham T; Vavalle JP
    Curr Cardiol Rep; 2024 May; 26(5):339-347. PubMed ID: 38472629
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Cerebral events and protection during transcatheter aortic valve replacement.
    Freeman M; Barbanti M; Wood DA; Ye J; Webb JG
    Catheter Cardiovasc Interv; 2014 Nov; 84(6):885-96. PubMed ID: 24550141
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effectiveness of embolic protection filter devices in stroke prevention during endovascular aortic arch repair in significant aortic atheroma patients.
    Shimamura K; Kuratani T; Kin K; Shijo T; Masada K; Sawa Y
    Interact Cardiovasc Thorac Surg; 2019 Jun; 28(6):974-980. PubMed ID: 30715362
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Embolic protection in patients undergoing transaortic transcatheter aortic valve replacement: initial experience with the TriGuard HDH embolic deflection device.
    Campelo-Parada F; Regueiro A; Dumont E; DeLarochellière R; Paradis JM; Mohammadi S; Doyle D; Rodés-Cabau J
    J Card Surg; 2016 Oct; 31(10):617-622. PubMed ID: 27577965
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Transcarotid TAVR: Towards a Better Understanding of Cerebral Embolic Events.
    Faroux L; Mohammadi S; Rodés-Cabau J
    Ann Thorac Surg; 2022 May; 113(5):1752. PubMed ID: 33974894
    [No Abstract]   [Full Text] [Related]  

  • 19. Increase Carotid Flow by Double Sheath Connection Technique to Reduce Cerebral Ischemia for Transcatheter Aortic Valve Implantation through Transcarotid Approach.
    Tsai R; Chen IM; Chen PL; Leu HB; Chen YH; Chang HH
    Ann Thorac Cardiovasc Surg; 2018 Jun; 24(3):161-164. PubMed ID: 29628466
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Cerebral embolic protection and severity of stroke following transcatheter aortic valve replacement.
    Isogai T; Vanguru HR; Krishnaswamy A; Agrawal A; Spilias N; Shekhar S; Saad AM; Verma BR; Puri R; Reed GW; Popović ZB; Unai S; Yun JJ; Uchino K; Kapadia SR
    Catheter Cardiovasc Interv; 2022 Nov; 100(5):810-820. PubMed ID: 35916117
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.