These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

181 related articles for article (PubMed ID: 30380315)

  • 61. Influence of the head model on EEG and MEG source connectivity analyses.
    Cho JH; Vorwerk J; Wolters CH; Knösche TR
    Neuroimage; 2015 Apr; 110():60-77. PubMed ID: 25638756
    [TBL] [Abstract][Full Text] [Related]  

  • 62. Volume currents in forward and inverse magnetoencephalographic simulations using realistic head models.
    Van Uitert R; Weinstein D; Johnson C
    Ann Biomed Eng; 2003 Jan; 31(1):21-31. PubMed ID: 12572653
    [TBL] [Abstract][Full Text] [Related]  

  • 63. Solving the forward problem in EEG source analysis by spherical and fdm head modeling: a comparative analysis - biomed 2009.
    Vatta F; Meneghini F; Esposito F; Mininel S; Di Salle F
    Biomed Sci Instrum; 2009; 45():382-8. PubMed ID: 19369793
    [TBL] [Abstract][Full Text] [Related]  

  • 64. Interictal spike localization using a standard realistic head model: simulations and analysis of clinical data.
    Silva C; Almeida R; Oostendorp T; Ducla-Soares E; Foreid JP; Pimentel T
    Clin Neurophysiol; 1999 May; 110(5):846-55. PubMed ID: 10400198
    [TBL] [Abstract][Full Text] [Related]  

  • 65. Reduction of the impact of multiple uncertain conductivity values on EEG dipole source analysis.
    Yitembe BR; Crevecoeur G; Van Keer R; Dupré L
    Int J Numer Method Biomed Eng; 2013 Mar; 29(3):363-79. PubMed ID: 23345195
    [TBL] [Abstract][Full Text] [Related]  

  • 66. [Five-layer realistic finite element head models based on segmented computer tomography data].
    Zhang J; Wu W; Ying X; Yan D
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2011 Jun; 28(3):587-91. PubMed ID: 21774229
    [TBL] [Abstract][Full Text] [Related]  

  • 67. Conductivity ratios of the scalp-skull-brain head model in estimating equivalent dipole sources in human brain.
    Homma S; Musha T; Nakajima Y; Okamoto Y; Blom S; Flink R; Hagbarth KE
    Neurosci Res; 1995 Mar; 22(1):51-5. PubMed ID: 7792082
    [TBL] [Abstract][Full Text] [Related]  

  • 68. Volume conduction effects in EEG and MEG.
    van den Broek SP; Reinders F; Donderwinkel M; Peters MJ
    Electroencephalogr Clin Neurophysiol; 1998 Jun; 106(6):522-34. PubMed ID: 9741752
    [TBL] [Abstract][Full Text] [Related]  

  • 69. New Strategy for Finite Element Mesh Generation for Accurate Solutions of Electroencephalography Forward Problems.
    Lee C; Im CH
    Brain Topogr; 2019 May; 32(3):354-362. PubMed ID: 30073558
    [TBL] [Abstract][Full Text] [Related]  

  • 70. High-resolution electroencephalography and source localization in neonates.
    Roche-Labarbe N; Aarabi A; Kongolo G; Gondry-Jouet C; Dümpelmann M; Grebe R; Wallois F
    Hum Brain Mapp; 2008 Feb; 29(2):167-76. PubMed ID: 17390314
    [TBL] [Abstract][Full Text] [Related]  

  • 71. Influences of skull segmentation inaccuracies on EEG source analysis.
    Lanfer B; Scherg M; Dannhauer M; Knösche TR; Burger M; Wolters CH
    Neuroimage; 2012 Aug; 62(1):418-31. PubMed ID: 22584227
    [TBL] [Abstract][Full Text] [Related]  

  • 72. Parametric surface-source modeling and estimation with electroencephalography.
    Cao N; Yetik IS; Nehorai A; Muravchik CH; Haueisen J
    IEEE Trans Biomed Eng; 2006 Dec; 53(12 Pt 1):2414-24. PubMed ID: 17153198
    [TBL] [Abstract][Full Text] [Related]  

  • 73. Geometry-adapted hexahedral meshes improve accuracy of finite-element-method-based EEG source analysis.
    Wolters CH; Anwander A; Berti G; Hartmann U
    IEEE Trans Biomed Eng; 2007 Aug; 54(8):1446-53. PubMed ID: 17694865
    [TBL] [Abstract][Full Text] [Related]  

  • 74. Influence of head tissue conductivity in forward and inverse magnetoencephalographic simulations using realistic head models.
    Van Uitert R; Johnson C; Zhukov L
    IEEE Trans Biomed Eng; 2004 Dec; 51(12):2129-37. PubMed ID: 15605860
    [TBL] [Abstract][Full Text] [Related]  

  • 75. Computational aspects of finite element modeling in EEG source localization.
    Awada KA; Jackson DR; Williams JT; Wilton DR; Baumann SB; Papanicolaou AC
    IEEE Trans Biomed Eng; 1997 Aug; 44(8):736-52. PubMed ID: 9254987
    [TBL] [Abstract][Full Text] [Related]  

  • 76. Influence of skull modeling approaches on EEG source localization.
    Montes-Restrepo V; van Mierlo P; Strobbe G; Staelens S; Vandenberghe S; Hallez H
    Brain Topogr; 2014 Jan; 27(1):95-111. PubMed ID: 24002699
    [TBL] [Abstract][Full Text] [Related]  

  • 77. Estimating brain conductivities and dipole source signals with EEG arrays.
    Gutiérrez D; Nehorai A; Muravchik CH
    IEEE Trans Biomed Eng; 2004 Dec; 51(12):2113-22. PubMed ID: 15605858
    [TBL] [Abstract][Full Text] [Related]  

  • 78. Forward field computation with OpenMEEG.
    Gramfort A; Papadopoulo T; Olivi E; Clerc M
    Comput Intell Neurosci; 2011; 2011():923703. PubMed ID: 21437231
    [TBL] [Abstract][Full Text] [Related]  

  • 79. Experimental validation of the influence of white matter anisotropy on the intracranial EEG forward solution.
    Bangera NB; Schomer DL; Dehghani N; Ulbert I; Cash S; Papavasiliou S; Eisenberg SR; Dale AM; Halgren E
    J Comput Neurosci; 2010 Dec; 29(3):371-87. PubMed ID: 20063051
    [TBL] [Abstract][Full Text] [Related]  

  • 80. Influence of head models on EEG simulations and inverse source localizations.
    Ramon C; Schimpf PH; Haueisen J
    Biomed Eng Online; 2006 Feb; 5():10. PubMed ID: 16466570
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.