These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

168 related articles for article (PubMed ID: 30386124)

  • 1. Management of anastomotic biliary stricture after liver transplantation: metal versus plastic stent.
    Facciorusso A; Rosca EC; Ashimi A; Ugoeze KC; Pathak U; Infante V; Muscatiello N
    Ann Gastroenterol; 2018; 31(6):728-734. PubMed ID: 30386124
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Management of liver transplantation biliary stricture: Results from a tertiary hospital.
    Martins FP; Kahaleh M; Ferrari AP
    World J Gastrointest Endosc; 2015 Jun; 7(7):747-57. PubMed ID: 26140103
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Covered Self-Expanding Metal Stents Versus Multiple Plastic Stents for Benign Biliary Strictures: An Updated Meta-Analysis of Randomized Controlled Trials.
    Giri S; Jearth V; Sundaram S
    Cureus; 2022 Apr; 14(4):e24588. PubMed ID: 35651420
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Multiple plastic versus fully covered metal stents for managing post-liver transplantation anastomotic biliary strictures: a meta-analysis of randomized controlled trials.
    Tringali A; Tarantino I; Barresi L; Traina M; Bonato G; Cintolo M; Hassan C; Mutignani M; Adler DG
    Ann Gastroenterol; 2019; 32(4):407-415. PubMed ID: 31263364
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Success and complications of an intra-ductal fully covered self-expanding metal stent (ID-FCSEMS) to treat anastomotic biliary strictures (AS) after orthotopic liver transplantation (OLT).
    Aepli P; St John A; Gupta S; Hourigan LF; Vaughan R; Efthymiou M; Kaffes A
    Surg Endosc; 2017 Apr; 31(4):1558-1563. PubMed ID: 27572066
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Metal versus plastic stents for anastomotic biliary strictures after liver transplantation: a randomized controlled trial.
    Martins FP; De Paulo GA; Contini MLC; Ferrari AP
    Gastrointest Endosc; 2018 Jan; 87(1):131.e1-131.e13. PubMed ID: 28455159
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of Covered Metallic Stents Compared With Plastic Stents on Benign Biliary Stricture Resolution: A Randomized Clinical Trial.
    Coté GA; Slivka A; Tarnasky P; Mullady DK; Elmunzer BJ; Elta G; Fogel E; Lehman G; McHenry L; Romagnuolo J; Menon S; Siddiqui UD; Watkins J; Lynch S; Denski C; Xu H; Sherman S
    JAMA; 2016 Mar 22-29; 315(12):1250-7. PubMed ID: 27002446
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Efficacy of different stent types in post-liver-transplant anastomotic biliary strictures: a systematic review and meta-analysis.
    Papaefthymiou A; Ramai D; Maida M; Tziatzios G; Facciorusso A; Triantafyllou K; Arvanitakis M; Johnson G; Phillpotts S; Webster G; Gkolfakis P
    Ann Gastroenterol; 2024; 37(4):485-492. PubMed ID: 38974085
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Endoscopic treatment of anastomotic biliary stricture after adult deceased donor liver transplantation with multiple plastic stents versus self-expandable metal stents: a systematic review and meta-analysis.
    Landi F; de'Angelis N; Sepulveda A; Martínez-Pérez A; Sobhani I; Laurent A; Soubrane O
    Transpl Int; 2018 Feb; 31(2):131-151. PubMed ID: 29090502
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Endoscopic Management of Anastomotic Strictures after Liver Transplantation.
    Lee DW; Jo HH; Abdullah J; Kahaleh M
    Clin Endosc; 2016 Sep; 49(5):457-461. PubMed ID: 27744664
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clinical efficacy of anti-migration features in fully covered metallic stents for anastomotic biliary strictures after liver transplantation: comparison of conventional and anti-migration stents.
    Bordaçahar B; Perdigao F; Leblanc S; Barret M; Duchmann JC; Guillaumot MA; Chaussade S; Scatton O; Prat F
    Gastrointest Endosc; 2018 Oct; 88(4):655-664. PubMed ID: 30003877
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Metallic vs plastic stents to treat biliary stricture after liver transplantation: a systematic review and meta-analysis based on randomized trials.
    Visconti TAC; Bernardo WM; Moura DTH; Moura ETH; Gonçalves CVT; Farias GF; Guedes HG; Ribeiro IB; Franzini TP; Luz GO; Dos Santos MEDL; de Moura EGH
    Endosc Int Open; 2018 Aug; 6(8):E914-E923. PubMed ID: 30258982
    [No Abstract]   [Full Text] [Related]  

  • 13. Safety and efficacy of Kaffes intraductal self-expanding metal stents in the management of post-liver transplant anastomotic strictures.
    Lim C; Ng J; Sarraf B; Vaughan R; Efthymiou M; Zorron Cheng Tao Pu L; Chandran S
    World J Transplant; 2024 Jun; 14(2):91081. PubMed ID: 38947975
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Endo-therapies for biliary duct-to-duct anastomotic stricture after liver transplantation: Outcomes of a nationwide survey.
    Cantù P; Tarantino I; Baldan A; Mutignani M; Tringali A; Lombardi G; Cerofolini A; Di Sario A; Catalano G; Bertani H; Ghinolfi D; Boarino V; Masci E; Bulajic M; Pisani A; Fantin A; Ligresti D; Barresi L; Traina M; Ravelli P; Forti E; Barbaro F; Costamagna G; Rodella L; Maroni L; Salizzoni M; Conigliaro R; Filipponi F; Merighi A; Staiano T; Monteleone M; Mazzaferro V; Zucchi E; Zilli M; Nadal E; Rosa R; Santi G; Parzanese I; De Carlis L; Donato MF; Lampertico P; Maggi U; Caccamo L; Rossi G; Vecchi M; Penagini R
    Liver Int; 2019 Jul; 39(7):1355-1362. PubMed ID: 30500104
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Metal versus plastic stents in the management of benign biliary strictures: systematic review and meta-analysis of randomized controlled trials.
    Kamal F; Ali Khan M; Lee-Smith W; Sharma S; Acharya A; Imam Z; Jowhar D; Esswein J; Kothadia J; Aziz M; Chandan S; Arain M; Howden CW; Ismail MK
    Eur J Gastroenterol Hepatol; 2022 May; 34(5):478-487. PubMed ID: 35170533
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Fully covered self-expanding metal stents for benign biliary stricture after orthotopic liver transplant: 5-year outcomes.
    Poley JW; Ponchon T; Puespoek A; Bruno M; Roy A; Peetermans J; Rousseau M; Lépilliez V; Dolak W; Tringali A; Blero D; Carr-Locke D; Costamagna G; Devière J;
    Gastrointest Endosc; 2020 Dec; 92(6):1216-1224. PubMed ID: 32417298
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Long-term outcomes of endoscopic treatment for duct-to-duct anastomotic strictures after living donor liver transplantation.
    Sato T; Kogure H; Nakai Y; Hamada T; Takahara N; Mizuno S; Kawaguchi Y; Akamatsu N; Kaneko J; Hasegawa K; Tada M; Tsujino T; Isayama H; Koike K
    Liver Int; 2019 Oct; 39(10):1954-1963. PubMed ID: 31436017
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Efficacy of self-expandable metal stents in management of benign biliary strictures and comparison with multiple plastic stents: a meta-analysis.
    Khan MA; Baron TH; Kamal F; Ali B; Nollan R; Ismail MK; Tombazzi C; Artifon ELA; Repici A; Khashab MA
    Endoscopy; 2017 Jul; 49(7):682-694. PubMed ID: 28561199
    [No Abstract]   [Full Text] [Related]  

  • 19. Self-Expandable Metallic Stent Is More Cost Efficient Than Plastic Stent in Treating Anastomotic Biliary Stricture.
    Jang S; Stevens T; Lopez R; Chahal P; Bhatt A; Sanaka M; Vargo JJ
    Dig Dis Sci; 2020 Feb; 65(2):600-608. PubMed ID: 31104197
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A randomized trial of a fully covered self-expandable metallic stent versus plastic stents in anastomotic biliary strictures after liver transplantation.
    Kaffes A; Griffin S; Vaughan R; James M; Chua T; Tee H; Dinesen L; Corte C; Gill R
    Therap Adv Gastroenterol; 2014 Mar; 7(2):64-71. PubMed ID: 24587819
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.