BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 30387294)

  • 1. External dosimetry audit for quality assurance of carbon-ion radiation therapy clinical trials.
    Mizuno H; Fukumura A; Kanematsu N; Yonai S; Shirai T; Yusa K; Yanou T; Suga M; Mizota M; Minohara S; Kanai T; Kamada T
    J Appl Clin Med Phys; 2019 Jan; 20(1):31-36. PubMed ID: 30387294
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dosimetric verification of radiotherapy treatment planning systems in Serbia: national audit.
    Rutonjski L; Petrović B; Baucal M; Teodorović M; Cudić O; Gershkevitsh E; Izewska J
    Radiat Oncol; 2012 Sep; 7():155. PubMed ID: 22971539
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical experience with EPID dosimetry for prostate IMRT pre-treatment dose verification.
    McDermott LN; Wendling M; van Asselen B; Stroom J; Sonke JJ; van Herk M; Mijnheer BJ
    Med Phys; 2006 Oct; 33(10):3921-30. PubMed ID: 17089854
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Testing the methodology for a dosimetric end-to-end audit of IMRT/VMAT: results of IAEA multicentre and national studies.
    Wesolowska P; Georg D; Lechner W; Kazantsev P; Bokulic T; Tedgren AC; Adolfsson E; Campos AM; Alves VGL; Suming L; Hao W; Ekendahl D; Koniarova I; Bulski W; Chelminski K; Samper JLA; Vinatha SP; Rakshit S; Siri S; Tomsejm M; Tenhunen M; Povall J; Kry SF; Followill DS; Thwaites DI; Izewska J
    Acta Oncol; 2019 Dec; 58(12):1731-1739. PubMed ID: 31423867
    [No Abstract]   [Full Text] [Related]  

  • 5. Volumetric-modulated arc therapy: effective and efficient end-to-end patient-specific quality assurance.
    O'Daniel J; Das S; Wu QJ; Yin FF
    Int J Radiat Oncol Biol Phys; 2012 Apr; 82(5):1567-74. PubMed ID: 21470797
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Clinical implementation of Dosimetry Check™ for TomoTherapy
    Chung E; Kwon D; Park T; Kang H; Chung Y
    J Appl Clin Med Phys; 2018 Nov; 19(6):193-199. PubMed ID: 30354001
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Establishment of an On-Site Dosimetric Audit Program with a Plastic Phantom].
    Tani K; Wakita A
    Igaku Butsuri; 2020; 40(3):88-96. PubMed ID: 32999255
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pixel response-based EPID dosimetry for patient specific QA.
    Han B; Ding A; Lu M; Xing L
    J Appl Clin Med Phys; 2017 Jan; 18(1):9-17. PubMed ID: 28291939
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dosimetry quality audit of high energy photon beams in greek radiotherapy centers.
    Hourdakis CJ; Boziari A
    Radiother Oncol; 2008 Apr; 87(1):132-41. PubMed ID: 18343514
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Characterization of a novel 3D printed patient specific phantom for quality assurance in cranial stereotactic radiosurgery applications.
    Makris DN; Pappas EP; Zoros E; Papanikolaou N; Saenz DL; Kalaitzakis G; Zourari K; Efstathopoulos E; Maris TG; Pappas E
    Phys Med Biol; 2019 May; 64(10):105009. PubMed ID: 30965289
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Testing the methodology for dosimetry audit of heterogeneity corrections and small MLC-shaped fields: Results of IAEA multi-center studies.
    Izewska J; Wesolowska P; Azangwe G; Followill DS; Thwaites DI; Arib M; Stefanic A; Viegas C; Suming L; Ekendahl D; Bulski W; Georg D
    Acta Oncol; 2016 Jul; 55(7):909-16. PubMed ID: 26934916
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A comparison of IROC and ACDS on-site audits of reference and non-reference dosimetry.
    Lye J; Kry S; Shaw M; Gibbons F; Keehan S; Lehmann J; Kron T; Followill D; Williams I
    Med Phys; 2019 Dec; 46(12):5878-5887. PubMed ID: 31494941
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A quality assurance method that utilizes 3D dosimetry and facilitates clinical interpretation.
    Oldham M; Thomas A; O'Daniel J; Juang T; Ibbott G; Adamovics J; Kirkpatrick JP
    Int J Radiat Oncol Biol Phys; 2012 Oct; 84(2):540-6. PubMed ID: 22361085
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Remote auditing of radiotherapy facilities using optically stimulated luminescence dosimeters.
    Lye J; Dunn L; Kenny J; Lehmann J; Kron T; Oliver C; Butler D; Alves A; Johnston P; Franich R; Williams I
    Med Phys; 2014 Mar; 41(3):032102. PubMed ID: 24593737
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An on-site audit system for dosimetry credentialing of intensity-modulated radiotherapy in Japanese Clinical Oncology Group (JCOG) clinical trials.
    Nakamura M; Minemura T; Ishikura S; Nishio T; Narita Y; Nishimura Y
    Phys Med; 2016 Aug; 32(8):987-91. PubMed ID: 27402255
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quantitative evaluation of 3D dosimetry for stereotactic volumetric-modulated arc delivery using COMPASS.
    Vikraman S; Manigandan D; Karrthick KP; Sambasivaselli R; Senniandavar V; Ramu M; Rajesh T; Lutz M; Muthukumaran M; Karthikeyan N; Tejinder K
    J Appl Clin Med Phys; 2014 Jan; 16(1):5128. PubMed ID: 25679152
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An external dosimetry audit programme to credential static and rotational IMRT delivery for clinical trials quality assurance.
    Eaton DJ; Tyler J; Backshall A; Bernstein D; Carver A; Gasnier A; Henderson J; Lee J; Patel R; Tsang Y; Yang H; Zotova R; Wells E
    Phys Med; 2017 Mar; 35():25-30. PubMed ID: 28236559
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Biological consequences of MLC calibration errors in IMRT delivery and QA.
    Moiseenko V; Lapointe V; James K; Yin L; Liu M; Pawlicki T
    Med Phys; 2012 Apr; 39(4):1917-24. PubMed ID: 22482613
    [TBL] [Abstract][Full Text] [Related]  

  • 19. END-TO-END AUDIT: COMPARISON OF TLD AND LITHIUM FORMATE EPR DOSIMETRY.
    Adolfsson E; Wesolowska P; Izewska J; Lund E; Tedgren ÅC
    Radiat Prot Dosimetry; 2019 Dec; 186(1):119-122. PubMed ID: 30929009
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A novel approach to SBRT patient quality assurance using EPID-based real-time transit dosimetry : A step to QA with in vivo EPID dosimetry.
    Moustakis C; Ebrahimi Tazehmahalleh F; Elsayad K; Fezeu F; Scobioala S
    Strahlenther Onkol; 2020 Feb; 196(2):182-192. PubMed ID: 31925465
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.