These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

168 related articles for article (PubMed ID: 30387897)

  • 1. Silent T
    Schulte RF; Buonincontri G; Costagli M; Menini A; Wiesinger F; Solana AB
    Magn Reson Med; 2019 Apr; 81(4):2277-2287. PubMed ID: 30387897
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Long-T
    Lee HM; Weiger M; Giehr C; Froidevaux R; Brunner DO; Rösler MB; Pruessmann KP
    Magn Reson Med; 2020 Feb; 83(2):412-426. PubMed ID: 31502718
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ultrashort echo time and zero echo time MRI at 7T.
    Larson PE; Han M; Krug R; Jakary A; Nelson SJ; Vigneron DB; Henry RG; McKinnon G; Kelley DA
    MAGMA; 2016 Jun; 29(3):359-70. PubMed ID: 26702940
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Multipathway multi-echo (MPME) imaging: all main MR parameters mapped based on a single 3D scan.
    Cheng CC; Preiswerk F; Hoge WS; Kuo TH; Madore B
    Magn Reson Med; 2019 Mar; 81(3):1699-1713. PubMed ID: 30320945
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Zero-gradient-excitation ramped hybrid encoding (zG
    Blunck Y; Moffat BA; Kolbe SC; Ordidge RJ; Cleary JO; Johnston LA
    Magn Reson Med; 2019 Feb; 81(2):1172-1180. PubMed ID: 30252156
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Filling the dead-time gap in zero echo time MRI: Principles compared.
    Froidevaux R; Weiger M; Brunner DO; Dietrich BE; Wilm BJ; Pruessmann KP
    Magn Reson Med; 2018 Apr; 79(4):2036-2045. PubMed ID: 28856717
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Looping Star.
    Wiesinger F; Menini A; Solana AB
    Magn Reson Med; 2019 Jan; 81(1):57-68. PubMed ID: 30106186
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Clinical Evaluation of Zero-Echo-Time Attenuation Correction for Brain 18F-FDG PET/MRI: Comparison with Atlas Attenuation Correction.
    Sekine T; Ter Voert EE; Warnock G; Buck A; Huellner M; Veit-Haibach P; Delso G
    J Nucl Med; 2016 Dec; 57(12):1927-1932. PubMed ID: 27339875
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Blip up-down acquisition for spin- and gradient-echo imaging (BUDA-SAGE) with self-supervised denoising enables efficient T
    Zhang Z; Cho J; Wang L; Liao C; Shin HG; Cao X; Lee J; Xu J; Zhang T; Ye H; Setsompop K; Liu H; Bilgic B
    Magn Reson Med; 2022 Aug; 88(2):633-650. PubMed ID: 35436357
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Model-based super-resolution reconstruction of T
    Bano W; Piredda GF; Davies M; Marshall I; Golbabaee M; Meuli R; Kober T; Thiran JP; Hilbert T
    Magn Reson Med; 2020 Mar; 83(3):906-919. PubMed ID: 31517404
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Processing of radial fast spin-echo data for obtaining T2 estimates from a single k-space data set.
    Altbach MI; Bilgin A; Li Z; Clarkson EW; Trouard TP; Gmitro AF
    Magn Reson Med; 2005 Sep; 54(3):549-59. PubMed ID: 16086321
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Limitations of skipping echoes for exponential T
    McPhee KC; Wilman AH
    J Magn Reson Imaging; 2018 Nov; 48(5):1432-1440. PubMed ID: 29687931
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A single-shot T
    Chu ML; Chang HC; Oshio K; Chen NK
    Magn Reson Med; 2018 Jan; 79(1):383-393. PubMed ID: 28480603
    [TBL] [Abstract][Full Text] [Related]  

  • 14. 3D-multi-echo radial imaging of
    Blunck Y; Josan S; Taqdees SW; Moffat BA; Ordidge RJ; Cleary JO; Johnston LA
    Magn Reson Med; 2018 Apr; 79(4):1950-1961. PubMed ID: 28752556
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accelerated 3D T
    Roccia E; Vidya Shankar R; Neji R; Cruz G; Munoz C; Botnar R; Goh V; Prieto C; Dregely I
    Magn Reson Med; 2019 Mar; 81(3):1795-1805. PubMed ID: 30368900
    [TBL] [Abstract][Full Text] [Related]  

  • 16. MR susceptibility contrast imaging using a 2D simultaneous multi-slice gradient-echo sequence at 7T.
    Bian W; Kerr AB; Tranvinh E; Parivash S; Zahneisen B; Han MH; Lock CB; Goubran M; Zhu K; Rutt BK; Zeineh MM
    PLoS One; 2019; 14(7):e0219705. PubMed ID: 31314813
    [TBL] [Abstract][Full Text] [Related]  

  • 17. T
    McPhee KC; Wilman AH
    Magn Reson Med; 2019 Mar; 81(3):2052-2063. PubMed ID: 30338866
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ramped hybrid encoding for improved ultrashort echo time imaging.
    Jang H; Wiens CN; McMillan AB
    Magn Reson Med; 2016 Sep; 76(3):814-25. PubMed ID: 26381890
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Enhanced detection of paramagnetic fluorine-19 magnetic resonance imaging agents using zero echo time sequence and compressed sensing.
    Chen J; Pal P; Ahrens ET
    NMR Biomed; 2022 Aug; 35(8):e4725. PubMed ID: 35262991
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Rapid dual-RF, dual-echo, 3D ultrashort echo time craniofacial imaging: A feasibility study.
    Lee H; Zhao X; Song HK; Zhang R; Bartlett SP; Wehrli FW
    Magn Reson Med; 2019 May; 81(5):3007-3016. PubMed ID: 30565286
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.