196 related articles for article (PubMed ID: 30394561)
1. Evaluating corrections for Eddy-currents and other EPI distortions in diffusion MRI: methodology and a dataset for benchmarking.
Irfanoglu MO; Sarlls J; Nayak A; Pierpaoli C
Magn Reson Med; 2019 Apr; 81(4):2774-2787. PubMed ID: 30394561
[TBL] [Abstract][Full Text] [Related]
2. Evaluation of eddy current distortion and field inhomogeneity distortion corrections in MR diffusion imaging using log-demons DIR method.
Arsenault T; Yin FF; Chino J; Craciunescu O; Chang JZ
Phys Med Biol; 2021 Jan; 66(3):035021. PubMed ID: 33202395
[TBL] [Abstract][Full Text] [Related]
3. Characterization and correction of diffusion gradient-induced eddy currents in second-order motion-compensated echo-planar and spiral cardiac DTI.
van Gorkum RJH; Guenthner C; Koethe A; Stoeck CT; Kozerke S
Magn Reson Med; 2022 Dec; 88(6):2378-2394. PubMed ID: 35916545
[TBL] [Abstract][Full Text] [Related]
4. Estimation of undistorted images in brain echo-planar images with distortions using the conjugate gradient method with anatomical regularization.
Kumazawa S; Yoshiura T
Med Phys; 2022 Dec; 49(12):7531-7544. PubMed ID: 35901497
[TBL] [Abstract][Full Text] [Related]
5. Correction of eddy-current distortions in diffusion tensor images using the known directions and strengths of diffusion gradients.
Zhuang J; Hrabe J; Kangarlu A; Xu D; Bansal R; Branch CA; Peterson BS
J Magn Reson Imaging; 2006 Nov; 24(5):1188-93. PubMed ID: 17024663
[TBL] [Abstract][Full Text] [Related]
6. Characterization and correction of time-varying eddy currents for diffusion MRI.
Valsamis JJ; Dubovan PI; Baron CA
Magn Reson Med; 2022 May; 87(5):2209-2223. PubMed ID: 34894640
[TBL] [Abstract][Full Text] [Related]
7. Simultaneous Motion and Distortion Correction Using Dual-Echo Diffusion-Weighted MRI.
Afacan O; Hoge WS; Wallace TE; Gholipour A; Kurugol S; Warfield SK
J Neuroimaging; 2020 May; 30(3):276-285. PubMed ID: 32374453
[TBL] [Abstract][Full Text] [Related]
8. Comparison of EPI distortion correction methods in diffusion tensor MRI using a novel framework.
Wu M; Chang LC; Walker L; Lemaitre H; Barnett AS; Marenco S; Pierpaoli C
Med Image Comput Comput Assist Interv; 2008; 11(Pt 2):321-9. PubMed ID: 18982621
[TBL] [Abstract][Full Text] [Related]
9. Geometric distortion correction of high-resolution 3 T diffusion tensor brain images.
Ardekani S; Sinha U
Magn Reson Med; 2005 Nov; 54(5):1163-71. PubMed ID: 16187289
[TBL] [Abstract][Full Text] [Related]
10. Eddy current-induced artifact correction in high b-value ex vivo human brain diffusion MRI with dynamic field monitoring.
Ramos-Llordén G; Park DJ; Kirsch JE; Scholz A; Keil B; Maffei C; Lee HH; Bilgic B; Edlow BL; Mekkaoui C; Yendiki A; Witzel T; Huang SY
Magn Reson Med; 2024 Feb; 91(2):541-557. PubMed ID: 37753621
[TBL] [Abstract][Full Text] [Related]
11. A quantitative comparison of two methods to correct eddy current-induced distortions in DT-MRI.
Muñoz Maniega S; Bastin ME; Armitage PA
Magn Reson Imaging; 2007 Apr; 25(3):341-9. PubMed ID: 17371723
[TBL] [Abstract][Full Text] [Related]
12. PSF mapping-based correction of eddy-current-induced distortions in diffusion-weighted echo-planar imaging.
In MH; Posnansky O; Speck O
Magn Reson Med; 2016 May; 75(5):2055-63. PubMed ID: 26096666
[TBL] [Abstract][Full Text] [Related]
13. Double-spin-echo diffusion weighting with a modified eddy current adjustment.
Finsterbusch J
Magn Reson Imaging; 2010 Apr; 28(3):434-40. PubMed ID: 20071120
[TBL] [Abstract][Full Text] [Related]
14. DR-BUDDI (Diffeomorphic Registration for Blip-Up blip-Down Diffusion Imaging) method for correcting echo planar imaging distortions.
Irfanoglu MO; Modi P; Nayak A; Hutchinson EB; Sarlls J; Pierpaoli C
Neuroimage; 2015 Feb; 106():284-99. PubMed ID: 25433212
[TBL] [Abstract][Full Text] [Related]
15. Prospective and retrospective high order eddy current mitigation for diffusion weighted echo planar imaging.
Xu D; Maier JK; King KF; Collick BD; Wu G; Peters RD; Hinks RS
Magn Reson Med; 2013 Nov; 70(5):1293-305. PubMed ID: 23325564
[TBL] [Abstract][Full Text] [Related]
16. Distortion correction of diffusion weighted MRI without reverse phase-encoding scans or field-maps.
Schilling KG; Blaber J; Hansen C; Cai L; Rogers B; Anderson AW; Smith S; Kanakaraj P; Rex T; Resnick SM; Shafer AT; Cutting LE; Woodward N; Zald D; Landman BA
PLoS One; 2020; 15(7):e0236418. PubMed ID: 32735601
[TBL] [Abstract][Full Text] [Related]
17. Correction of eddy current distortions in high angular resolution diffusion imaging.
Zhuang J; Lu ZL; Vidal CB; Damasio H
J Magn Reson Imaging; 2013 Jun; 37(6):1460-7. PubMed ID: 23172807
[TBL] [Abstract][Full Text] [Related]
18. Correction of eddy current-induced artefacts in diffusion tensor imaging using iterative cross-correlation.
Bastin ME
Magn Reson Imaging; 1999 Sep; 17(7):1011-24. PubMed ID: 10463652
[TBL] [Abstract][Full Text] [Related]
19. A field-monitoring-based approach for correcting eddy-current-induced artifacts of up to the 2
Ma R; Akçakaya M; Moeller S; Auerbach E; Uğurbil K; Van de Moortele PF
Neuroimage; 2020 Aug; 216():116861. PubMed ID: 32305565
[TBL] [Abstract][Full Text] [Related]
20. Quantitative analysis of spatial distortions of diffusion techniques at 3T.
Xu D; Lee MC; Carballido-Gamio J; Barkovich M; Majumdar S; Vigneron DB; Nelson SJ
Magn Reson Imaging; 2010 Apr; 28(3):451-4. PubMed ID: 20096524
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]