These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
300 related articles for article (PubMed ID: 30398238)
1. Preparation of Ag@zeolitic imidazolate framework-67 at room temperature for electrochemical sensing of hydrogen peroxide. Dong Y; Duan C; Sheng Q; Zheng J Analyst; 2019 Jan; 144(2):521-529. PubMed ID: 30398238 [TBL] [Abstract][Full Text] [Related]
2. One-Step Electrodeposition of Silver Nanostructures on 2D/3D Metal-Organic Framework ZIF-67: Comparison and Application in Electrochemical Detection of Hydrogen Peroxide. Sun D; Yang D; Wei P; Liu B; Chen Z; Zhang L; Lu J ACS Appl Mater Interfaces; 2020 Sep; 12(37):41960-41968. PubMed ID: 32805814 [TBL] [Abstract][Full Text] [Related]
3. A Novel Non-Enzymatic Electrochemical Hydrogen Peroxide Sensor Based on a Metal-Organic Framework/Carbon Nanofiber Composite. Fu Y; Dai J; Ge Y; Zhang Y; Ke H; Zhang W Molecules; 2018 Oct; 23(10):. PubMed ID: 30301225 [TBL] [Abstract][Full Text] [Related]
4. Novel Ag@TiO2 nanocomposite synthesized by electrochemically active biofilm for nonenzymatic hydrogen peroxide sensor. Khan MM; Ansari SA; Lee J; Cho MH Mater Sci Eng C Mater Biol Appl; 2013 Dec; 33(8):4692-9. PubMed ID: 24094177 [TBL] [Abstract][Full Text] [Related]
5. Carbon nanotube hollow polyhedrons derived from ZIF-8@ZIF-67 coupled to electro-deposited gold nanoparticles for voltammetric determination of acetaminophen. Jin Y; Li X; Ge C; Ma J; Li Y; Zhao E; Yao S; Xu G; Li D Mikrochim Acta; 2019 Dec; 187(1):6. PubMed ID: 31797062 [TBL] [Abstract][Full Text] [Related]
6. Synergistic effect of the composite films formed by zeolitic imidazolate framework 8 (ZIF-8) and porous nickel films for enhanced amperometric sensing of hydrazine. Shi E; Lin H; Wang Q; Zhang F; Shi S; Zhang T; Li X; Niu H; Qu F Dalton Trans; 2017 Jan; 46(2):554-563. PubMed ID: 27975085 [TBL] [Abstract][Full Text] [Related]
7. One-step synthesis of a Methylene Blue@ZIF-8-reduced graphene oxide nanocomposite and its application to electrochemical sensing of rutin. Wang Z; Yu G; Xia J; Zhang F; Liu Q Mikrochim Acta; 2018 May; 185(5):279. PubMed ID: 29725773 [TBL] [Abstract][Full Text] [Related]
8. Facile fabrication of Pt-Ag bimetallic nanoparticles decorated reduced graphene oxide for highly sensitive non-enzymatic hydrogen peroxide sensing. Zhang C; Zhang Y; Du X; Chen Y; Dong W; Han B; Chen Q Talanta; 2016 Oct; 159():280-286. PubMed ID: 27474309 [TBL] [Abstract][Full Text] [Related]
9. Non-enzymatic monitoring of hydrogen peroxide using novel nanosensor based on CoFe Mollarasouli F; Kurbanoglu S; Asadpour-Zeynali K; Ozkan SA Anal Bioanal Chem; 2020 Aug; 412(21):5053-5065. PubMed ID: 31897559 [TBL] [Abstract][Full Text] [Related]
10. Comparative study of carbon fiber structure on the electrocatalytic performance of ZIF-67. Feng X; Lin S; Li M; Bo X; Guo L Anal Chim Acta; 2017 Sep; 984():96-106. PubMed ID: 28843573 [TBL] [Abstract][Full Text] [Related]
11. Non-enzymatic electrochemical hydrogen peroxide sensing using a nanocomposite prepared from silver nanoparticles and copper (II)-porphyrin derived metal-organic framework nanosheets. Ma J; Bai W; Zheng J Mikrochim Acta; 2019 Jun; 186(7):482. PubMed ID: 31250119 [TBL] [Abstract][Full Text] [Related]
12. Nitrogen-rich core-shell structured particles consisting of carbonized zeolitic imidazolate frameworks and reduced graphene oxide for amperometric determination of hydrogen peroxide. Li Z; Jiang Y; Wang Z; Wang W; Yuan Y; Wu X; Liu X; Li M; Dilpazir S; Zhang G; Wang D; Liu C; Jiang J Mikrochim Acta; 2018 Oct; 185(11):501. PubMed ID: 30302565 [TBL] [Abstract][Full Text] [Related]
13. A Non-enzymatic Electrochemical Sensor for Glucose Detection Based on Ag@TiO Arif D; Hussain Z; Sohail M; Liaqat MA; Khan MA; Noor T Front Chem; 2020; 8():573510. PubMed ID: 33195063 [TBL] [Abstract][Full Text] [Related]
14. Facile synthesis of a zeolitic imidazolate framework-8 with reduced graphene oxide hybrid material as an efficient electrocatalyst for nonenzymatic H Yang S; Xia N; Li M; Liu P; Wang Y; Qu L RSC Adv; 2019 May; 9(27):15217-15223. PubMed ID: 35514807 [TBL] [Abstract][Full Text] [Related]
15. Synthesis of single-crystal α-MnO2 nanotubes-loaded Ag@C core-shell matrix and their application for electrochemical sensing of nonenzymatic hydrogen peroxide. Zhang S; Zheng J Talanta; 2016 Oct; 159():231-237. PubMed ID: 27474303 [TBL] [Abstract][Full Text] [Related]
16. Electrochemical study of acetaminophen oxidation by gold nanoparticles supported on a leaf-like zeolitic imidazolate framework. Wang L; Meng T; Fan Y; Chen C; Guo Z; Wang H; Zhang Y J Colloid Interface Sci; 2018 Aug; 524():1-7. PubMed ID: 29627667 [TBL] [Abstract][Full Text] [Related]
17. A hybrid material composed of reduced graphene oxide and porous carbon prepared by carbonization of a zeolitic imidazolate framework (type ZIF-8) for voltammetric determination of chloramphenicol. Yuan Y; Xu X; Xia J; Zhang F; Wang Z; Liu Q Mikrochim Acta; 2019 Feb; 186(3):191. PubMed ID: 30778741 [TBL] [Abstract][Full Text] [Related]
18. A reagentless non-enzymatic hydrogen peroxide sensor presented using electrochemically reduced graphene oxide modified glassy carbon electrode. Mutyala S; Mathiyarasu J Mater Sci Eng C Mater Biol Appl; 2016 Dec; 69():398-406. PubMed ID: 27612728 [TBL] [Abstract][Full Text] [Related]
19. Ag nanoparticles decorated into metal-organic framework (Ag NPs/ZIF-8) for electrochemical sensing of chloride ion. Bin Q; Wang M; Wang L Nanotechnology; 2020 Mar; 31(12):125601. PubMed ID: 31778989 [TBL] [Abstract][Full Text] [Related]
20. Amperometric sensing of ascorbic acid by using a glassy carbon electrode modified with mesoporous carbon nanorods. Li X; Liu J; Sun M; Sha T; Bo X; Zhou M Mikrochim Acta; 2018 Sep; 185(10):474. PubMed ID: 30242490 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]