These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 30399727)

  • 1.
    Seo SH
    Rev Sci Instrum; 2018 Oct; 89(10):10H121. PubMed ID: 30399727
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development of frequency modulation reflectometer for Korea Superconducting Tokamak Advanced Research tokamak.
    Seo SH; Park J; Wi HM; Lee WR; Kim HS; Lee TG; Kim YS; Kang JS; Bog MG; Yokota Y; Mase A
    Rev Sci Instrum; 2013 Aug; 84(8):084702. PubMed ID: 24007083
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development of frequency modulated continuous wave reflectometer for electron density profile measurement on the HL-2A tokamak.
    Zhong WL; Shi ZB; Huang XL; Liu ZT; Chen W; Jiang M; Li J; Cui ZY; Song XM; Chen LY; Zou XL; Ding XT; Liu Y; Yan LW; Yang QW; Duan XR
    Rev Sci Instrum; 2014 Jan; 85(1):013507. PubMed ID: 24517765
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development of frequency modulation reflectometer for KSTAR tokamak: data analysis based on Gaussian derivative wavelet.
    Seo SH; Lee KD
    Rev Sci Instrum; 2012 Oct; 83(10):10E342. PubMed ID: 23126999
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A frequency-modulated continuous-wave reflectometer for the Lithium Tokamak Experiment.
    Kubota S; Majeski R; Peebles WA; Bell RE; Boyle DP; Kaita R; Kozub T; Lucia M; Merino E; Nguyen XV; Rhodes TL; Schmitt JC
    Rev Sci Instrum; 2017 May; 88(5):053502. PubMed ID: 28571454
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Microwave reflectometer for density profile and turbulence measurements on the COMPASS tokamak.
    Bogar O; Zajac J; Zacek F; Varavin M; Hron M; Panek R; Silva A
    Rev Sci Instrum; 2020 Jan; 91(1):013515. PubMed ID: 32012635
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Design of a Doppler reflectometer for KSTAR.
    Lee KD; Nam YU; Seo SH; Kim YS
    Rev Sci Instrum; 2014 Nov; 85(11):11D858. PubMed ID: 25430271
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Rapidly and continuously frequency-scanning opto-electronic oscillator.
    Cen Q; Dai Y; Yin F; Zhou Y; Li J; Dai J; Yu L; Xu K
    Opt Express; 2017 Jan; 25(2):635-643. PubMed ID: 28157953
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Measurements of electron density profile by frequency modulated continuous wave reflectometer in the T-10 tokamak using high magnetic field side probing and extraordinary mode lower cutoff.
    Shelukhin DA; Vershkov VA; Subbotin GF; Sarychev DV; Petrov AA; Petrov VG; Sokolov MM; Igonkina GB
    Rev Sci Instrum; 2018 Sep; 89(9):094708. PubMed ID: 30278723
    [TBL] [Abstract][Full Text] [Related]  

  • 10. V-band frequency hopping microwave reflectometer in LHD.
    Tokuzawa T; Ejiri A; Kawahata K; Tanaka K; Ito Y
    Rev Sci Instrum; 2008 Oct; 79(10):10F109. PubMed ID: 19044593
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Edge scanning reflectometry for density profile measurement on the SPARC tokamak.
    Lin Y; Nikolaeva V; Hachmeister D; Kowalski E; Reinke ML
    Rev Sci Instrum; 2024 Aug; 95(8):. PubMed ID: 39166911
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Time-frequency analysis for microwave reflectometry data processing in the HL-2A tokamak.
    Zhong WL; Shi ZB; Zou XL; Ding XT; Huang XL; Dong YB; Liu ZT; Xiao WW; Ji XQ; Cui ZY; Liu Y; Yan LW; Yang QW; Duan XR
    Rev Sci Instrum; 2011 Oct; 82(10):103508. PubMed ID: 22047295
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Microwave Doppler reflectometer system in the Experimental Advanced Superconducting Tokamak.
    Zhou C; Liu AD; Zhang XH; Hu JQ; Wang MY; Li H; Lan T; Xie JL; Sun X; Ding WX; Liu WD; Yu CX
    Rev Sci Instrum; 2013 Oct; 84(10):103511. PubMed ID: 24182112
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Robust measurement of group delay in the presence of density fluctuations by means of ultrafast swept reflectometry.
    Cavazzana R; Moresco M
    Rev Sci Instrum; 2008 Oct; 79(10):10F105. PubMed ID: 19044592
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Use of the absolute phase in frequency modulated continuous wave plasma reflectometry.
    Cunningham G
    Rev Sci Instrum; 2008 Aug; 79(8):083501. PubMed ID: 19044343
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Simultaneous projection and detection system of four different frequencies for microwave imaging reflectometry in Large Helical Device.
    Yoshinaga T; Nagayama Y; Kuwahara D; Tsuchiya H; Yamaguchi S; Kogi Y; Tsuji-Iio S; Mase A
    Rev Sci Instrum; 2010 Oct; 81(10):10D915. PubMed ID: 21033947
    [TBL] [Abstract][Full Text] [Related]  

  • 17. System-on-chip approach microwave imaging reflectometer on DIII-D tokamak.
    Zhu Y; Chen Y; Yu JH; Domier C; Yu G; Liu X; Kramer G; Ren Y; Diallo A; Luhmann NC; Li X
    Rev Sci Instrum; 2022 Nov; 93(11):113509. PubMed ID: 36461457
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Multi-channel poloidal correlation reflectometry on experimental advanced superconducting tokamak.
    Qu H; Zhang T; Han X; Xiang HM; Wen F; Geng KN; Wang YM; Kong DF; Cai JQ; Huang CB; Gao Y; Gao X; Zhang S
    Rev Sci Instrum; 2016 Nov; 87(11):11E707. PubMed ID: 27910349
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A novel multi-channel quadrature Doppler backward scattering reflectometer on the HL-2A tokamak.
    Shi Z; Zhong W; Jiang M; Yang Z; Zhang B; Shi P; Chen W; Wen J; Chen C; Fu B; Liu Z; Ding X; Yang Q; Duan X
    Rev Sci Instrum; 2016 Nov; 87(11):113501. PubMed ID: 27910662
    [TBL] [Abstract][Full Text] [Related]  

  • 20. First density profile measurements using frequency modulation of the continuous wave reflectometry on JET.
    Meneses L; Cupido L; Sirinelli A; Manso ME;
    Rev Sci Instrum; 2008 Oct; 79(10):10F108. PubMed ID: 19068528
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.