These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

160 related articles for article (PubMed ID: 30399772)

  • 1. Progress on next generation gamma-ray Cherenkov detectors for the National Ignition Facility.
    Herrmann HW; Kim YH; Zylstra AB; Geppert-Kleinrath H; Meaney KD; Young CS; Lopez FE; Fatherley VE; Pederson BJ; Oertel JA; Hernandez JE; Carrera J; Khater H; Rubery MS; Horsfield CJ; Gales S; Leatherland A; Hilsabeck T; Kilkenny JD; Malone RM; Batha SH
    Rev Sci Instrum; 2018 Oct; 89(10):10I148. PubMed ID: 30399772
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Next generation gamma-ray Cherenkov detectors for the National Ignition Facility.
    Herrmann HW; Kim YH; McEvoy AM; Zylstra AB; Young CS; Lopez FE; Griego JR; Fatherley VE; Oertel JA; Stoeffl W; Khater H; Hernandez JE; Carpenter A; Rubery MS; Horsfield CJ; Gales S; Leatherland A; Hilsabeck T; Kilkenny JD; Malone RM; Hares JD; Milnes J; Shmayda WT; Stoeckl C; Batha SH
    Rev Sci Instrum; 2016 Nov; 87(11):11E732. PubMed ID: 27910331
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Pulse dilation gas Cherenkov detector for ultra-fast gamma reaction history at the NIF (invited).
    Geppert-Kleinrath H; Herrmann HW; Kim YH; Zylstra AB; Meaney K; Lopez FE; Pederson BJ; Carrera J; Khater H; Horsfield CJ; Rubery MS; Gales S; Leatherland A; Meadowcroft A; Hilsabeck T; Kilkenny JD; Malone RM; Hares JD; Dymoke-Bradshaw AKL; Milnes J; McFee C
    Rev Sci Instrum; 2018 Oct; 89(10):10I146. PubMed ID: 30399731
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Extended performance gas Cherenkov detector for gamma-ray detection in high-energy density experiments.
    Herrmann HW; Kim YH; Young CS; Fatherley VE; Lopez FE; Oertel JA; Malone RM; Rubery MS; Horsfield CJ; Stoeffl W; Zylstra AB; Shmayda WT; Batha SH
    Rev Sci Instrum; 2014 Nov; 85(11):11E124. PubMed ID: 25430303
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Development of an ultra-fast photomultiplier tube for gamma-ray Cherenkov detectors at the National Ignition Facility (PD-PMT).
    Dymoke-Bradshaw AKL; Hares JD; Milnes J; Herrmann HW; Horsfield CJ; Gales SG; Leatherland A; Hilsabeck T; Kilkenny JD
    Rev Sci Instrum; 2018 Oct; 89(10):10I137. PubMed ID: 30399690
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The Vacuum Cherenkov Detector (VCD) for γ-ray measurements in inertial confinement fusion experiments.
    Jeet J; Zylstra AB; Rekow V; Hardy CM; Pelepchan N; Eckart M; Kim Y; Rubery M; Moore AS; Schlossberg DJ; Folsom E
    Rev Sci Instrum; 2022 Oct; 93(10):103543. PubMed ID: 36319345
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Improved inertial confinement fusion gamma reaction history
    Meaney KD; Kim YH; Herrmann HW; Geppert-Kleinrath H; Hoffman NM
    Rev Sci Instrum; 2019 Nov; 90(11):113503. PubMed ID: 31779396
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Diagnosing inertial confinement fusion gamma ray physics (invited).
    Herrmann HW; Hoffman N; Wilson DC; Stoeffl W; Dauffy L; Kim YH; McEvoy A; Young CS; Mack JM; Horsfield CJ; Rubery M; Miller EK; Ali ZA
    Rev Sci Instrum; 2010 Oct; 81(10):10D333. PubMed ID: 21033853
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Optimization of the gamma reaction history diagnostic for double-shell pusher areal density and reaction history measurements on the National Ignition Facility.
    Dwyer RH; Meaney KD; Geppert-Kleinrath H; Loomis EN; Robey HF; Mohamed ZL; Fry C; Kim Y
    Rev Sci Instrum; 2024 Mar; 95(3):. PubMed ID: 38497838
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Characterisation of a sub-20 ps temporal resolution pulse dilation photomultiplier tube.
    Gales SG; Horsfield CJ; Meadowcroft AL; Leatherland AE; Herrmann HW; Hares JD; Dymoke-Bradshaw AKL; Milnes JS; Kim YH; Kleinrath HG; Meaney K; Zylstra AB; Parker S; Hussey D; Wilson L; James SF; Kilkenny JD; Hilsabeck TJ
    Rev Sci Instrum; 2018 Jun; 89(6):063506. PubMed ID: 29960515
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Gamma bang time analysis at OMEGA.
    McEvoy AM; Herrmann HW; Horsfield CJ; Young CS; Miller EK; Mack JM; Kim Y; Stoeffl W; Rubery M; Evans S; Sedillo T; Ali ZA
    Rev Sci Instrum; 2010 Oct; 81(10):10D322. PubMed ID: 21033846
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cherenkov radiation conversion and collection considerations for a gamma bang time/reaction history diagnostic for the NIF.
    Herrmann HW; Mack JM; Young CS; Malone RM; Stoeffl W; Horsfield CJ
    Rev Sci Instrum; 2008 Oct; 79(10):10E531. PubMed ID: 19044512
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Gamma bang time/reaction history diagnostics for the National Ignition Facility using 90 degrees off-axis parabolic mirrors.
    Malone RM; Herrmann HW; Stoeffl W; Mack JM; Young CS
    Rev Sci Instrum; 2008 Oct; 79(10):10E532. PubMed ID: 19044513
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Solid Cherenkov detector for studying nucleosynthesis in inertial confinement fusion.
    Springstead MP; Zylstra AB; Kim Y; Meaney KD; Geppert-Kleinrath H; Leatherland A; Wilson L; Herrmann HW; Young CS; Polk P; Hamilton C
    Rev Sci Instrum; 2020 Jul; 91(7):073503. PubMed ID: 32752853
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Monte Carlo validation experiments for the gas Cherenkov detectors at the National Ignition Facility and Omega.
    Rubery MS; Horsfield CJ; Herrmann H; Kim Y; Mack JM; Young C; Evans S; Sedillo T; McEvoy A; Caldwell SE; Grafil E; Stoeffl W; Milnes JS
    Rev Sci Instrum; 2013 Jul; 84(7):073504. PubMed ID: 23902060
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Gamma-to-electron magnetic spectrometer (GEMS): an energy-resolved γ-ray diagnostic for the National Ignition Facility.
    Kim Y; Herrmann HW; Hilsabeck TJ; Moy K; Stoeffl W; Mack JM; Young CS; Wu W; Barlow DB; Schillig JB; Sims JR; Lopez FE; Mares D; Oertel JA; Hayes-Sterbenz AC
    Rev Sci Instrum; 2012 Oct; 83(10):10D311. PubMed ID: 23126838
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Development and characterization of sub-100 ps photomultiplier tubes.
    Horsfield CJ; Rubery MS; Mack JM; Young CS; Herrmann HW; Caldwell SE; Evans SC; Sedilleo TJ; Kim YH; McEvoy A; Milnes JS; Howorth J; Davis B; O'Gara PM; Garza I; Miller EK; Stoeffl W; Ali Z
    Rev Sci Instrum; 2010 Oct; 81(10):10D318. PubMed ID: 21033844
    [TBL] [Abstract][Full Text] [Related]  

  • 18. High-density carbon capsule experiments on the national ignition facility.
    Ross JS; Ho D; Milovich J; Döppner T; McNaney J; MacPhee AG; Hamza A; Biener J; Robey HF; Dewald EL; Tommasini R; Divol L; Le Pape S; Berzak Hopkins L; Celliers PM; Landen O; Meezan NB; Mackinnon AJ
    Phys Rev E Stat Nonlin Soft Matter Phys; 2015 Feb; 91(2):021101. PubMed ID: 25768451
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The conceptual design of 1-ps time resolution neutron detector for fusion reaction history measurement at OMEGA and the National Ignition Facility.
    Arikawa Y; Ota M; Nakajima M; Shimizu T; Segawa S; Khoa Phan TN; Sakawa Y; Abe Y; Morace A; Mirfayzi SR; Yogo A; Fujioka S; Nakai M; Shiraga H; Azechi H; Kodama R; Kan K; Frenje J; Gatu Johnson M; Bose A; Kabadi NV; Sutcliffe GD; Adrian P; Li C; Séguin FH; Petrasso R
    Rev Sci Instrum; 2020 Jun; 91(6):063304. PubMed ID: 32611003
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The magnetic recoil spectrometer (MRSt) for time-resolved measurements of the neutron spectrum at the National Ignition Facility (NIF).
    Frenje JA; Hilsabeck TJ; Wink CW; Bell P; Bionta R; Cerjan C; Gatu Johnson M; Kilkenny JD; Li CK; Séguin FH; Petrasso RD
    Rev Sci Instrum; 2016 Nov; 87(11):11D806. PubMed ID: 27910467
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.