These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

148 related articles for article (PubMed ID: 30407190)

  • 21. Clinical evaluations of an amplitude-based binning algorithm for 4DCT reconstruction in radiation therapy.
    Li H; Noel C; Garcia-Ramirez J; Low D; Bradley J; Robinson C; Mutic S; Parikh P
    Med Phys; 2012 Feb; 39(2):922-32. PubMed ID: 22320802
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Feasibility study of Compton cameras for x-ray fluorescence computed tomography with humans.
    Vernekohl D; Ahmad M; Chinn G; Xing L
    Phys Med Biol; 2016 Dec; 61(24):8521-8540. PubMed ID: 27845933
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Improving x-ray fluorescence signal for benchtop polychromatic cone-beam x-ray fluorescence computed tomography by incident x-ray spectrum optimization: a Monte Carlo study.
    Manohar N; Jones BL; Cho SH
    Med Phys; 2014 Oct; 41(10):101906. PubMed ID: 25281958
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Folic acid supplementation and malaria susceptibility and severity among people taking antifolate antimalarial drugs in endemic areas.
    Crider K; Williams J; Qi YP; Gutman J; Yeung L; Mai C; Finkelstain J; Mehta S; Pons-Duran C; Menéndez C; Moraleda C; Rogers L; Daniels K; Green P
    Cochrane Database Syst Rev; 2022 Feb; 2(2022):. PubMed ID: 36321557
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Image quality of microcalcifications in digital breast tomosynthesis: effects of projection-view distributions.
    Lu Y; Chan HP; Wei J; Goodsitt M; Carson PL; Hadjiiski L; Schmitz A; Eberhard JW; Claus BE
    Med Phys; 2011 Oct; 38(10):5703-12. PubMed ID: 21992385
    [TBL] [Abstract][Full Text] [Related]  

  • 26. A cascaded model of spectral distortions due to spectral response effects and pulse pileup effects in a photon-counting x-ray detector for CT.
    Cammin J; Xu J; Barber WC; Iwanczyk JS; Hartsough NE; Taguchi K
    Med Phys; 2014 Apr; 41(4):041905. PubMed ID: 24694136
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A comparative study of a dual-energy-like imaging technique based on counting-integrating readout.
    Roessl E; Herrmann C; Kraft E; Proksa R
    Med Phys; 2011 Dec; 38(12):6416-28. PubMed ID: 22149825
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Seeing elements by visible-light digital camera.
    Zhao W; Sakurai K
    Sci Rep; 2017 Mar; 7():45472. PubMed ID: 28361916
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Broadband high-energy resolution hard x-ray spectroscopy using transition edge sensors at SPring-8.
    Yamada S; Ichinohe Y; Tatsuno H; Hayakawa R; Suda H; Ohashi T; Ishisaki Y; Uruga T; Sekizawa O; Nitta K; Takahashi Y; Itai T; Suga H; Nagasawa M; Tanaka M; Kurisu M; Hashimoto T; Bennett D; Denison E; Doriese WB; Durkin M; Fowler J; O'Neil G; Morgan K; Schmidt D; Swetz D; Ullom J; Vale L; Okada S; Okumura T; Azuma T; Tamagawa T; Isobe T; Kohjiro S; Noda H; Tanaka K; Taguchi A; Imai Y; Sato K; Hayashi T; Kashiwabara T; Sakata K
    Rev Sci Instrum; 2021 Jan; 92(1):013103. PubMed ID: 33514202
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Sufficient statistics as a generalization of binning in spectral X-ray imaging.
    Wang AS; Pelc NJ
    IEEE Trans Med Imaging; 2011 Jan; 30(1):84-93. PubMed ID: 20682470
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Visualization of bone details in a novel photon-counting dual-source CT scanner-comparison with energy-integrating CT.
    Bette SJ; Braun FM; Haerting M; Decker JA; Luitjens JH; Scheurig-Muenkler C; Kroencke TJ; Schwarz F
    Eur Radiol; 2022 May; 32(5):2930-2936. PubMed ID: 34936011
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Hard X-ray nanoprobe investigations of the subtissue metal distributions within Daphnia magna.
    De Samber B; De Schamphelaere KA; Janssen CR; Vekemans B; De Rycke R; Martinez-Criado G; Tucoulou R; Cloetens P; Vincze L
    Anal Bioanal Chem; 2013 Jul; 405(18):6061-8. PubMed ID: 23681201
    [TBL] [Abstract][Full Text] [Related]  

  • 33. X-ray Fluorescence Emission Tomography (XFET) with Novel Imaging Geometries - A Monte Carlo Study.
    Meng LJ; Li N; La Riviere PJ
    IEEE Trans Nucl Sci; 2011 Dec; 58(6):3359-3369. PubMed ID: 22228913
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Synchrotron radiation micro X-ray fluorescence spectroscopy of thin structures in bone samples: comparison of confocal and color X-ray camera setups.
    Rauwolf M; Turyanskaya A; Roschger A; Prost J; Simon R; Scharf O; Radtke M; Schoonjans T; Guilherme Buzanich A; Klaushofer K; Wobrauschek P; Hofstaetter JG; Roschger P; Streli C
    J Synchrotron Radiat; 2017 Jan; 24(Pt 1):307-311. PubMed ID: 28009572
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Monte-Carlo study of contrast-enhanced spectral mammography with cadmium telluride photon-counting x-ray detectors.
    Day JA; Tanguay J
    Med Phys; 2024 Apr; 51(4):2479-2498. PubMed ID: 37967277
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Imaging properties of digital magnification radiography.
    Boyce SJ; Samei E
    Med Phys; 2006 Apr; 33(4):984-96. PubMed ID: 16696475
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A method for energy window optimization for quantitative tasks that includes the effects of model-mismatch on bias: application to Y-90 bremsstrahlung SPECT imaging.
    Rong X; Du Y; Frey EC
    Phys Med Biol; 2012 Jun; 57(12):3711-25. PubMed ID: 22617760
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A Monte Carlo Model of a Benchtop X-Ray Fluorescence Computed Tomography System and Its Application to Validate a Deconvolution-Based X-Ray Fluorescence Signal Extraction Method.
    Ahmed MF; Yasar S; Cho SH
    IEEE Trans Med Imaging; 2018 Nov; 37(11):2483-2492. PubMed ID: 29994762
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A list-mode multi-energy window low-count SPECT reconstruction method for isotopes with multiple emission peaks.
    Rahman MA; Li Z; Yu Z; Laforest R; Thorek DLJ; Jha AK
    EJNMMI Phys; 2023 Jun; 10(1):40. PubMed ID: 37347319
    [TBL] [Abstract][Full Text] [Related]  

  • 40.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.