BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

163 related articles for article (PubMed ID: 30408074)

  • 21. Mixed venous O2 saturation: measured by co-oximetry versus calculated from PVO2.
    Nierman DM; Schechter CB
    J Clin Monit; 1994 Jan; 10(1):39-44. PubMed ID: 8126537
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Continuous monitoring of ScvO(2) by a new fibre-optic technology compared with blood gas oximetry in critically ill patients: a multicentre study.
    Molnar Z; Umgelter A; Toth I; Livingstone D; Weyland A; Sakka SG; Meier-Hellmann A
    Intensive Care Med; 2007 Oct; 33(10):1767-70. PubMed ID: 17576533
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Trends but not individual values of central venous oxygen saturation agree with mixed venous oxygen saturation during varying hemodynamic conditions.
    Dueck MH; Klimek M; Appenrodt S; Weigand C; Boerner U
    Anesthesiology; 2005 Aug; 103(2):249-57. PubMed ID: 16052106
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Continuous central venous oximetry and shock index in the emergency department: use in the evaluation of clinical shock.
    Rady MY; Rivers EP; Martin GB; Smithline H; Appelton T; Nowak RM
    Am J Emerg Med; 1992 Nov; 10(6):538-41. PubMed ID: 1388378
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Comparison of central-venous to mixed-venous oxygen saturation during changes in oxygen supply/demand.
    Reinhart K; Rudolph T; Bredle DL; Hannemann L; Cain SM
    Chest; 1989 Jun; 95(6):1216-21. PubMed ID: 2721255
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Adequate agreement between venous oxygen saturation in right atrium and pulmonary artery in critically ill children.
    Pérez AC; Eulmesekian PG; Minces PG; Schnitzler EJ
    Pediatr Crit Care Med; 2009 Jan; 10(1):76-9. PubMed ID: 19057448
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Oxygen tissue saturation is lower in nonsurvivors than in survivors after early resuscitation of septic shock.
    Leone M; Blidi S; Antonini F; Meyssignac B; Bordon S; Garcin F; Charvet A; Blasco V; Albanèse J; Martin C
    Anesthesiology; 2009 Aug; 111(2):366-71. PubMed ID: 19602965
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Central venous versus mixed venous oxygen content.
    Faber T
    Acta Anaesthesiol Scand Suppl; 1995; 107():33-6. PubMed ID: 8599294
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Central venous oxygen saturation and emergency intubation--another piece in the puzzle?
    Stahl W; Radermacher P; Georgieff M; Bracht H
    Crit Care; 2009; 13(4):172. PubMed ID: 19678914
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Central venous oxygen saturation for the diagnosis of low cardiac output in septic shock patients.
    Perner A; Haase N; Wiis J; White JO; Delaney A
    Acta Anaesthesiol Scand; 2010 Jan; 54(1):98-102. PubMed ID: 19735495
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Optimizing hemodynamic support in septic shock using central and mixed venous oxygen saturation.
    Maddirala S; Khan A
    Crit Care Clin; 2010 Apr; 26(2):323-33, table of contents. PubMed ID: 20381723
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Equipment review: the success of early goal-directed therapy for septic shock prompts evaluation of current approaches for monitoring the adequacy of resuscitation.
    Gunn SR; Fink MP; Wallace B
    Crit Care; 2005 Aug; 9(4):349-59. PubMed ID: 16137384
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The value of venous oximetry.
    Reinhart K; Bloos F
    Curr Opin Crit Care; 2005 Jun; 11(3):259-63. PubMed ID: 15928476
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Tissue oxygenation does not predict central venous oxygenation in emergency department patients with severe sepsis and septic shock.
    Napoli AM; Machan JT; Forcada A; Corl K; Gardiner F
    Acad Emerg Med; 2010 Apr; 17(4):349-52. PubMed ID: 20370772
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Resonance Raman spectroscopy: a new technology for tissue oxygenation monitoring.
    Ward KR; Torres Filho I; Barbee RW; Torres L; Tiba MH; Reynolds PS; Pittman RN; Ivatury RR; Terner J
    Crit Care Med; 2006 Mar; 34(3):792-9. PubMed ID: 16521273
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Use of a peripheral perfusion index derived from the pulse oximetry signal as a noninvasive indicator of perfusion.
    Lima AP; Beelen P; Bakker J
    Crit Care Med; 2002 Jun; 30(6):1210-3. PubMed ID: 12072670
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Changes in central venous saturation after major surgery, and association with outcome.
    Pearse R; Dawson D; Fawcett J; Rhodes A; Grounds RM; Bennett ED
    Crit Care; 2005; 9(6):R694-9. PubMed ID: 16356220
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Mixed venous oxygen saturation in critically ill septic shock patients. The role of defined events.
    Krafft P; Steltzer H; Hiesmayr M; Klimscha W; Hammerle AF
    Chest; 1993 Mar; 103(3):900-6. PubMed ID: 8449089
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Comparison of blood gas values in arterial and venous blood.
    Kirubakaran C; Gnananayagam JE; Sundaravalli EK
    Indian J Pediatr; 2003 Oct; 70(10):781-5. PubMed ID: 14649471
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Continuous central venous oxygen saturation (ScvO2) measurement using a fibre optic catheter in newborn infants.
    van der Hoeven MA; Maertzdorf WJ; Blanco CE
    Arch Dis Child Fetal Neonatal Ed; 1996 May; 74(3):F177-81. PubMed ID: 8777680
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.