These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 30416244)

  • 1. Signal and noise characteristics of a CdTe-based photon counting detector: Cascaded systems analysis and experimental studies.
    Ji X; Zhang R; Ge Y; Chen GH; Li K
    Proc SPIE Int Soc Opt Eng; 2017 Feb; 10132():. PubMed ID: 30416244
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Impact of anti-charge sharing on the zero-frequency detective quantum efficiency of CdTe-based photon counting detector system: cascaded systems analysis and experimental validation.
    Ji X; Zhang R; Chen GH; Li K
    Phys Med Biol; 2018 May; 63(9):095003. PubMed ID: 29582785
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The detective quantum efficiency of cadmium telluride photon-counting x-ray detectors in breast imaging applications.
    Day JA; Tanguay J
    Med Phys; 2022 Mar; 49(3):1481-1494. PubMed ID: 34905627
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Cascaded systems analysis of photon counting detectors.
    Xu J; Zbijewski W; Gang G; Stayman JW; Taguchi K; Lundqvist M; Fredenberg E; Carrino JA; Siewerdsen JH
    Med Phys; 2014 Oct; 41(10):101907. PubMed ID: 25281959
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Monte-Carlo study of contrast-enhanced spectral mammography with cadmium telluride photon-counting x-ray detectors.
    Day JA; Tanguay J
    Med Phys; 2024 Apr; 51(4):2479-2498. PubMed ID: 37967277
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cascaded systems analysis of charge sharing in cadmium telluride photon-counting x-ray detectors.
    Tanguay J; Cunningham IA
    Med Phys; 2018 May; 45(5):1926-1941. PubMed ID: 29526029
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Spectroscopy with a CdTe-based photon-counting imaging detector (PCD) having charge sharing correction capability.
    Shankar A; Krebs J; Bednarek DR; Rudin S
    Proc SPIE Int Soc Opt Eng; 2018 Feb; 10573():. PubMed ID: 29899588
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of a new photon-counting imaging detector (PCD) with various acquisition modes.
    Shankar A; Krebs J; Bednarek DR; Rudin S
    Proc SPIE Int Soc Opt Eng; 2018 Feb; 10573():. PubMed ID: 29881136
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Frequency-dependent signal and noise in spectroscopic x-ray imaging.
    Tanguay J; Kim J; Kim HK; Iniewski K; Cunningham IA
    Med Phys; 2020 Jul; 47(7):2881-2901. PubMed ID: 32239517
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Spatio-energetic cross-talk in photon counting detectors: Numerical detector model (PcTK) and workflow for CT image quality assessment.
    Taguchi K; Stierstorfer K; Polster C; Lee O; Kappler S
    Med Phys; 2018 May; 45(5):1985-1998. PubMed ID: 29537627
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Theoretical comparison and optimization of cadmium telluride and gallium arsenide photon-counting detectors for contrast-enhanced spectral mammography.
    Schaeffer C; Ghammraoui B; Taguchi K; Glick SJ
    J Med Imaging (Bellingham); 2023 Feb; 10(Suppl 2):S22406. PubMed ID: 37056579
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Spatio-energetic cross talk in photon counting detectors: Detector model and correlated Poisson data generator.
    Taguchi K; Polster C; Lee O; Stierstorfer K; Kappler S
    Med Phys; 2016 Dec; 43(12):6386. PubMed ID: 27908175
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Spectral resolution and high-flux capability tradeoffs in CdTe detectors for clinical CT.
    Hsieh SS; Rajbhandary PL; Pelc NJ
    Med Phys; 2018 Apr; 45(4):1433-1443. PubMed ID: 29418004
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation and comparison of a CdTe based photon counting detector with an energy integrating detector for X-ray phase sensitive imaging of breast cancer.
    Ghani MU; Omoumi FH; Wu X; Fajardo LL; Zheng B; Liu H
    J Xray Sci Technol; 2022; 30(2):207-219. PubMed ID: 34957945
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Improving digital charge sharing compensation in photon counting detectors with a low-threshold comparator.
    Hsieh SS; Iniewski K
    Med Phys; 2021 Oct; 48(10):5819-5829. PubMed ID: 34370321
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Multi-energy inter-pixel coincidence counters for charge sharing correction and compensation in photon counting detectors.
    Taguchi K
    Med Phys; 2020 Jun; 47(5):2085-2098. PubMed ID: 31984498
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Feasibility of multi-contrast imaging on dual-source photon counting detector (PCD) CT: An initial phantom study.
    Tao S; Rajendran K; McCollough CH; Leng S
    Med Phys; 2019 Sep; 46(9):4105-4115. PubMed ID: 31215659
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Simultaneous photon counting and charge integrating for pulse pile-up correction in paralyzable photon counting detectors.
    Treb K; Radtke J; Culberson WS; Li K
    Phys Med Biol; 2023 Jul; 68(15):. PubMed ID: 37379858
    [No Abstract]   [Full Text] [Related]  

  • 19. Digital count summing vs analog charge summing for photon counting detectors: A performance simulation study.
    Hsieh SS; Sjolin M
    Med Phys; 2018 Jul; ():. PubMed ID: 30027678
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Detective efficiency of photon counting detectors with spectral degradation and crosstalk.
    Rajbhandary PL; Persson M; Pelc NJ
    Med Phys; 2020 Jan; 47(1):27-36. PubMed ID: 31665541
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.