128 related articles for article (PubMed ID: 30416781)
1. Suturing of the laser resection area is recommended over a depth of 2 cm in an experimental porcine lung model.
Kirschbaum A; Surowiec TM; Pehl A; Gockel A; Bartsch DK; Mirow N
J Thorac Dis; 2018 Sep; 10(9):5339-5345. PubMed ID: 30416781
[TBL] [Abstract][Full Text] [Related]
2. Airtightness of lung parenchyma without a closing suture after atypical resection using the Nd:YAG Laser LIMAX 120.
Kirschbaum A; Steinfeldt T; Gockel A; Di Fazio P; Quint K; Bartsch DK
Interact Cardiovasc Thorac Surg; 2014 Jan; 18(1):92-5. PubMed ID: 24087831
[TBL] [Abstract][Full Text] [Related]
3. Local lung coagulation post resection: an ex-vivo porcine model.
Kirschbaum A; Surowiec TM; Pehl A; Wiesmann T; Bartsch DK; Mirow N
Lasers Med Sci; 2022 Feb; 37(1):443-447. PubMed ID: 33759033
[TBL] [Abstract][Full Text] [Related]
4. Investigations of initial airtightness after non-anatomic resection of lung parenchyma using a thulium-doped laser with different optical fibres.
Kirschbaum A; Höchsmann N; Steinfeldt T; Seyfer P; Pehl A; Bartsch DK; Palade E
Lasers Med Sci; 2016 Aug; 31(6):1097-103. PubMed ID: 27184155
[TBL] [Abstract][Full Text] [Related]
5. Initial Airtightness of the Lung Parenchyma After Transection of the Interlobar Fissure - Monopolar Cutter, Stapler Versus Nd: YAG Laser.
Kirschbaum A; Eigendorf P; Wiesmann T; Mirow N; Meyer C
J Surg Res; 2022 Oct; 278():79-85. PubMed ID: 35594618
[TBL] [Abstract][Full Text] [Related]
6. Comparison of local tissue damage: monopolar cutter versus Nd:YAG laser for lung parenchyma resection. An experimental study.
Kirschbaum A; Braun S; Rexin P; Bartsch DK; Seyfer P
Interact Cardiovasc Thorac Surg; 2014 Jan; 18(1):1-6. PubMed ID: 24130089
[TBL] [Abstract][Full Text] [Related]
7. Determination of initial airtightness after anatomical laser segmentectomy in an ex vivo model.
Kirschbaum A; Ivanovic A; Wiesmann T; Mirow N; Meyer C
Lasers Med Sci; 2022 Mar; 37(2):815-820. PubMed ID: 33891211
[TBL] [Abstract][Full Text] [Related]
8. Comparison of the local effects of a 600-μm bare fibre at high laser power on lung parenchyma: Nd:YAG laser 1320 vs. 1064 nm.
Kirschbaum A; Bartsch DK; Rexin P
Lasers Med Sci; 2017 Apr; 32(3):557-562. PubMed ID: 28110368
[TBL] [Abstract][Full Text] [Related]
9. Dosimetry studies utilizing the urolase right-angle firing neodymium:YAG laser fiber in the human prostate.
Kabalin JN; Terris MK; Mancianti ML; Fajardo LF
Lasers Surg Med; 1996; 18(1):72-80. PubMed ID: 8850468
[TBL] [Abstract][Full Text] [Related]
10. BipoJet Scissors as an Alternative to Laser in Lung Wedge Resection.
Prisadov G; Welcker K; Herrmann K; Kesieme EB; Linder A
Cureus; 2024 May; 16(5):e60088. PubMed ID: 38860077
[TBL] [Abstract][Full Text] [Related]
11. Bipolar sealing of lung parenchyma: tests in an ex vivo model.
Kirschbaum A; Clemens A; Steinfeldt T; Pehl A; Meyer C; Bartsch DK
Surg Endosc; 2015 Jan; 29(1):127-32. PubMed ID: 25027470
[TBL] [Abstract][Full Text] [Related]
12. Comparison of continuous versus pulsed CO2 and Nd:YAG laser-induced pulmonary parenchymal lung injury in a rabbit model.
Brenner M; Wang NS; Shankel T; Waite TA; Milner T; Wong H; Hamilton A; Kono T; Tadir Y; Tromberg B; Wilson AF
Lasers Surg Med; 1996; 19(4):416-23. PubMed ID: 8983001
[TBL] [Abstract][Full Text] [Related]
13. The Nd:YAG LIMAX® 120 high-output laser: local effects and resection capacity on liver parenchyma.
Kirschbaum A; Rexin P; Bartsch DK; Di Fazio P
Lasers Med Sci; 2014 Jul; 29(4):1411-6. PubMed ID: 24562392
[TBL] [Abstract][Full Text] [Related]
14. [Local resection of pulmonary lesions by Nd-YAG laser without suturing].
Kuwabara M; Itoi K; Okubo K; Matsuoka K; Yanagihara K; Takata T
Nihon Kyobu Geka Gakkai Zasshi; 1993 Aug; 41(8):1286-90. PubMed ID: 8360527
[TBL] [Abstract][Full Text] [Related]
15. Suture or Stapling Are Superior in Comparison to Bipolar Sealing for Closing the Bronchi.
Kirschbaum A; Waubke K; Pehl A; Steinfeldt T; Bartsch DK
Thorac Cardiovasc Surg; 2017 Aug; 65(5):356-361. PubMed ID: 27380379
[No Abstract] [Full Text] [Related]
16. Comparison of Ho:YAG versus Nd:YAG thoracoscopic laser treatment of pulmonary bullae in a rabbit model.
Brenner M; Wong H; Yoong B; Wang NS; Chen JC; Budd M; Hamilton A; Tadir Y; McKenna R; Fischel RJ; Huh J; Tromberg B; Wilson AF
J Clin Laser Med Surg; 1997; 15(3):103-8. PubMed ID: 9612156
[TBL] [Abstract][Full Text] [Related]
17. Initial Resistance of Carina Anastomoses with Increasing Tensile Stress: An ex vivo Model Comparing Different Suture Techniques.
Kirschbaum A; Hemmerling S; Steinfeldt T; Bartsch DK; Mirow N
Eur Surg Res; 2017; 58(1-2):20-26. PubMed ID: 27577554
[TBL] [Abstract][Full Text] [Related]
18. [Thoracoscopic partial resection of the lung by use of Nd-YAG laser and standard suturing technique].
Otsuka T; Kouno T; Nakajima J; Furuse A; Takizawa H; Oka T
Kyobu Geka; 1993 Dec; 46(13):1106-9. PubMed ID: 8258912
[TBL] [Abstract][Full Text] [Related]
19. Heat dissipation after nonanatomical lung resection using a laser is mainly due to emission to the environment: an experimental ex vivo study.
Kirschbaum A; Ocker M; Bartsch DK; Quint K
Lasers Med Sci; 2014 May; 29(3):1037-42. PubMed ID: 24146236
[TBL] [Abstract][Full Text] [Related]
20. Effect of high laser output on the central bronchi and pulmonary artery.
Kirschbaum A; Rexin P; Bartsch DK; Quint K
Lasers Med Sci; 2017 May; 32(4):881-886. PubMed ID: 28293872
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]