412 related articles for article (PubMed ID: 30418608)
21. Cryptogenic stroke: Is silent atrial fibrillation the culprit?
Glotzer TV; Ziegler PD
Heart Rhythm; 2015 Jan; 12(1):234-41. PubMed ID: 25285649
[TBL] [Abstract][Full Text] [Related]
22. Multicenter randomized study of anticoagulation guided by remote rhythm monitoring in patients with implantable cardioverter-defibrillator and CRT-D devices: Rationale, design, and clinical characteristics of the initially enrolled cohort The IMPACT study.
Ip J; Waldo AL; Lip GY; Rothwell PM; Martin DT; Bersohn MM; Choucair WK; Akar JG; Wathen MS; Rohani P; Halperin JL;
Am Heart J; 2009 Sep; 158(3):364-370.e1. PubMed ID: 19699858
[TBL] [Abstract][Full Text] [Related]
23. Improving atrial fibrillation detection in patients with implantable cardiac devices by means of a remote monitoring and management application.
Zoppo F; Facchin D; Molon G; Zanotto G; Catanzariti D; Rossillo A; Baccillieri MS; Menard C; Comisso J; Gentili A; Grammatico A; Bertaglia E; Proclemer A
Pacing Clin Electrophysiol; 2014 Dec; 37(12):1610-8. PubMed ID: 25113510
[TBL] [Abstract][Full Text] [Related]
24. Subclinical and Device-Detected Atrial Fibrillation: Pondering the Knowledge Gap: A Scientific Statement From the American Heart Association.
Noseworthy PA; Kaufman ES; Chen LY; Chung MK; Elkind MSV; Joglar JA; Leal MA; McCabe PJ; Pokorney SD; Yao X;
Circulation; 2019 Dec; 140(25):e944-e963. PubMed ID: 31694402
[TBL] [Abstract][Full Text] [Related]
25. Atrial fibrillation burden and atrial fibrillation type: Clinical significance and impact on the risk of stroke and decision making for long-term anticoagulation.
Boriani G; Pettorelli D
Vascul Pharmacol; 2016 Aug; 83():26-35. PubMed ID: 27196706
[TBL] [Abstract][Full Text] [Related]
26. Early detection of occult atrial fibrillation and stroke prevention.
Keach JW; Bradley SM; Turakhia MP; Maddox TM
Heart; 2015 Jul; 101(14):1097-102. PubMed ID: 25935765
[TBL] [Abstract][Full Text] [Related]
27. Disease management: atrial fibrillation and home monitoring.
Ricci RP
Europace; 2013 Jun; 15 Suppl 1():i35-i39. PubMed ID: 23737228
[TBL] [Abstract][Full Text] [Related]
28. Assessment of Remote Heart Rhythm Sampling Using the AliveCor Heart Monitor to Screen for Atrial Fibrillation: The REHEARSE-AF Study.
Halcox JPJ; Wareham K; Cardew A; Gilmore M; Barry JP; Phillips C; Gravenor MB
Circulation; 2017 Nov; 136(19):1784-1794. PubMed ID: 28851729
[TBL] [Abstract][Full Text] [Related]
29. Stroke incidence in patients with cardiac implantable electronic devices remotely controlled with automatic alerts of atrial fibrillation. A sub-analysis of the HomeGuide study.
Ricci RP; Vaccari D; Morichelli L; Zanotto G; Calò L; D'Onofrio A; Curnis A; Pisanò EC; Nangah R; Brieda M; Calzolari V; Melissano D; Rovai N; Gargaro A
Int J Cardiol; 2016 Sep; 219():251-6. PubMed ID: 27340918
[TBL] [Abstract][Full Text] [Related]
30. Atrial Fibrillation Burden and Short-Term Risk of Stroke: Case-Crossover Analysis of Continuously Recorded Heart Rhythm From Cardiac Electronic Implanted Devices.
Turakhia MP; Ziegler PD; Schmitt SK; Chang Y; Fan J; Than CT; Keung EK; Singer DE
Circ Arrhythm Electrophysiol; 2015 Oct; 8(5):1040-7. PubMed ID: 26175528
[TBL] [Abstract][Full Text] [Related]
31. Uncovering Atrial Fibrillation Beyond Short-Term Monitoring in Cryptogenic Stroke Patients: Three-Year Results From the Cryptogenic Stroke and Underlying Atrial Fibrillation Trial.
Brachmann J; Morillo CA; Sanna T; Di Lazzaro V; Diener HC; Bernstein RA; Rymer M; Ziegler PD; Liu S; Passman RS
Circ Arrhythm Electrophysiol; 2016 Jan; 9(1):e003333. PubMed ID: 26763225
[TBL] [Abstract][Full Text] [Related]
32. Frequent Premature Atrial Contractions in Cryptogenic Stroke Predict Atrial Fibrillation Detection with Insertable Cardiac Monitoring.
Todo K; Iwata T; Doijiri R; Yamagami H; Morimoto M; Hashimoto T; Sonoda K; Yamazaki H; Koge J; Okazaki S; Sasaki T; Mochizuki H
Cerebrovasc Dis; 2020; 49(2):144-150. PubMed ID: 32023609
[TBL] [Abstract][Full Text] [Related]
33. Atrial Fibrillation in Patients with Embolic Stroke of Undetermined Source during 3 Years of Prolonged Monitoring with an Implantable Loop Recorder.
Kitsiou A; Rogalewski A; Kalyani M; Deelawar S; Tribunyan S; Greeve I; Minnerup J; Israel C; Schäbitz WR
Thromb Haemost; 2021 Jun; 121(6):826-833. PubMed ID: 33401327
[TBL] [Abstract][Full Text] [Related]
34. Smartwatch Performance for the Detection and Quantification of Atrial Fibrillation.
Wasserlauf J; You C; Patel R; Valys A; Albert D; Passman R
Circ Arrhythm Electrophysiol; 2019 Jun; 12(6):e006834. PubMed ID: 31113234
[TBL] [Abstract][Full Text] [Related]
35. Atrial high-rate episodes and stroke prevention.
Camm AJ; Simantirakis E; Goette A; Lip GY; Vardas P; Calvert M; Chlouverakis G; Diener HC; Kirchhof P
Europace; 2017 Feb; 19(2):169-179. PubMed ID: 28172715
[TBL] [Abstract][Full Text] [Related]
36. Device-detected atrial fibrillation in a large remote-monitored cohort: implications for anticoagulation and need for new pathways of service delivery.
O'Shea CJ; Brooks AG; Middeldorp ME; Harper C; Hendriks JM; Russo AM; Freeman JV; Gopinathannair R; Varma N; Deering TF; Campbell K; Sanders P
J Interv Card Electrophysiol; 2023 Oct; 66(7):1659-1668. PubMed ID: 36735111
[TBL] [Abstract][Full Text] [Related]
37. Risk Assessment of Stroke in Patients with Atrial Fibrillation: Current Shortcomings and Future Directions.
Hyman DA; Siebert V; Jia X; Alam M; Levine GN; Virani SS; Birnbaum Y
Cardiovasc Drugs Ther; 2019 Feb; 33(1):105-117. PubMed ID: 30684116
[TBL] [Abstract][Full Text] [Related]
38. The Role of Cardiovascular Implantable Electronic Devices in the Detection and Treatment of Subclinical Atrial Fibrillation: A Review.
Hess PL; Healey JS; Granger CB; Connolly SJ; Ziegler PD; Alexander JH; Kowey PR; Ruff CT; Flaker G; Halperin JL; Hart RG; Lopes RD
JAMA Cardiol; 2017 Mar; 2(3):324-331. PubMed ID: 28097334
[TBL] [Abstract][Full Text] [Related]
39. External continuous ECG versus loop recording for atrial fibrillation detection in patients who had a stroke.
Sejr MH; May O; Damgaard D; Sandal BF; Nielsen JC
Heart; 2019 Jun; 105(11):848-854. PubMed ID: 30898849
[TBL] [Abstract][Full Text] [Related]
40. Role of Remote Monitoring in Detection of Atrial Arrhythmia, Stroke Reduction, and Use of Anticoagulation Therapy - A Systematic Review and Meta-Analysis.
Jang JP; Lin HT; Chen YJ; Hsieh MH; Huang YC
Circ J; 2020 Oct; 84(11):1922-1930. PubMed ID: 33012748
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]