179 related articles for article (PubMed ID: 30419572)
1. Whole-Body CT in Multiple Trauma Patients: Clinically Adapted Usage of Differently Weighted CT Protocols.
Reske SU; Braunschweig R; Reske AW; Loose R; Wucherer M
Rofo; 2018 Dec; 190(12):1141-1151. PubMed ID: 30419572
[TBL] [Abstract][Full Text] [Related]
2. Whole-body CT-based imaging algorithm for multiple trauma patients: radiation dose and time to diagnosis.
Gordic S; Alkadhi H; Hodel S; Simmen HP; Brueesch M; Frauenfelder T; Wanner G; Sprengel K
Br J Radiol; 2015 Mar; 88(1047):20140616. PubMed ID: 25594105
[TBL] [Abstract][Full Text] [Related]
3. Influence of arm positioning on radiation dose for whole body computed tomography in trauma patients.
Bayer J; Pache G; Strohm PC; Zwingmann J; Blanke P; Baumann T; Südkamp NP; Hammer T
J Trauma; 2011 Apr; 70(4):900-5. PubMed ID: 20962679
[TBL] [Abstract][Full Text] [Related]
4. Whole-body CT in polytrauma patients: effect of arm positioning on thoracic and abdominal image quality.
Karlo C; Gnannt R; Frauenfelder T; Leschka S; Brüesch M; Wanner GA; Alkadhi H
Emerg Radiol; 2011 Aug; 18(4):285-93. PubMed ID: 21472460
[TBL] [Abstract][Full Text] [Related]
5. Computed tomography in trauma patients using iterative reconstruction: reducing radiation exposure without loss of image quality.
Kahn J; Grupp U; Kaul D; Böning G; Lindner T; Streitparth F
Acta Radiol; 2016 Mar; 57(3):362-9. PubMed ID: 25852193
[TBL] [Abstract][Full Text] [Related]
6. Quality and Dose Optimized CT Trauma Protocol - Recommendation from a University Level-I Trauma Center.
Kahn J; Kaul D; Böning G; Rotzinger R; Freyhardt P; Schwabe P; Maurer MH; Renz DM; Streitparth F
Rofo; 2017 Sep; 189(9):844-854. PubMed ID: 28651263
[No Abstract] [Full Text] [Related]
7. Dose reduction in 64-row whole-body CT in multiple trauma: an optimized CT protocol with iterative image reconstruction on a gemstone-based scintillator.
Geyer LL; Körner M; Harrieder A; Mueck FG; Deak Z; Wirth S; Linsenmaier U
Br J Radiol; 2016; 89(1061):20160003. PubMed ID: 26853510
[TBL] [Abstract][Full Text] [Related]
8. Radiation exposure in whole-body computed tomography of multiple trauma patients: bearing devices and patient positioning.
Loewenhardt B; Buhl M; Gries A; Greim CA; Hellinger A; Hessmann M; Rathjen T; Reinert M; Manke C; Bernhard M
Injury; 2012 Jan; 43(1):67-72. PubMed ID: 22055141
[TBL] [Abstract][Full Text] [Related]
9. Association of Low-Dose Whole-Body Computed Tomography With Missed Injury Diagnoses and Radiation Exposure in Patients With Blunt Multiple Trauma.
Stengel D; Mutze S; Güthoff C; Weigeldt M; von Kottwitz K; Runge D; Razny F; Lücke A; Müller D; Ekkernkamp A; Kahl T
JAMA Surg; 2020 Mar; 155(3):224-232. PubMed ID: 31940019
[TBL] [Abstract][Full Text] [Related]
10. A new low-dose multi-phase trauma CT protocol and its impact on diagnostic assessment and radiation dose in multi-trauma patients.
Alagic Z; Eriksson A; Drageryd E; Motamed SR; Wick MC
Emerg Radiol; 2017 Oct; 24(5):509-518. PubMed ID: 28378236
[TBL] [Abstract][Full Text] [Related]
11. Imaging algorithms and CT protocols in trauma patients: survey of Swiss emergency centers.
Hinzpeter R; Boehm T; Boll D; Constantin C; Del Grande F; Fretz V; Leschka S; Ohletz T; Brönnimann M; Schmidt S; Treumann T; Poletti PA; Alkadhi H
Eur Radiol; 2017 May; 27(5):1922-1928. PubMed ID: 27595837
[TBL] [Abstract][Full Text] [Related]
12. Optimization of Whole-Body CT Examinations of Polytrauma Patients in Comparison with the Current Diagnostic Reference Levels.
Schäfer SB; Rudolph C; Kolodziej M; Mauermann F; Roller FC; Krombach GA
Rofo; 2019 Nov; 191(11):1015-1025. PubMed ID: 30999381
[TBL] [Abstract][Full Text] [Related]
13. The role of whole-body computed tomography in the diagnosis of thoracic injuries in severely injured patients - a retrospective multi-centre study based on the trauma registry of the German trauma society (TraumaRegister DGU
Lang P; Kulla M; Kerwagen F; Lefering R; Friemert B; Palm HG;
Scand J Trauma Resusc Emerg Med; 2017 Aug; 25(1):82. PubMed ID: 28810921
[TBL] [Abstract][Full Text] [Related]
14. Optimising whole body computed tomography doses for paediatric trauma patients: a Swiss retrospective analysis.
Simma L; Fornaro J; Stahr N; Lehner M; Roos JE; Lima TVM
J Radiol Prot; 2022 Apr; 42(2):. PubMed ID: 35354135
[TBL] [Abstract][Full Text] [Related]
15. Major trauma with only dynamic criteria: is the routine use of whole-body CT as a first level examination justified?
Mulas V; Catalano L; Geatti V; Alinari B; Ragusa F; Golfieri R; Orlandi PE; Imbriani M
Radiol Med; 2022 Jan; 127(1):65-71. PubMed ID: 34843028
[TBL] [Abstract][Full Text] [Related]
16. Correlation Between Traumatic Skin and Subcutaneous Injuries and the Severity of Polytrauma Injury.
Klempka A; Fischer C; Kauczor HU; Weber MA
Rofo; 2021 Feb; 193(2):177-185. PubMed ID: 33242897
[TBL] [Abstract][Full Text] [Related]
17. A decision tool for whole-body CT in major trauma that safely reduces unnecessary scanning and associated radiation risks: An initial exploratory analysis.
Davies RM; Scrimshire AB; Sweetman L; Anderton MJ; Holt EM
Injury; 2016 Jan; 47(1):43-9. PubMed ID: 26377772
[TBL] [Abstract][Full Text] [Related]
18. Whole body 16-row multislice CT in emergency room: effects of different protocols on scanning time, image quality and radiation exposure.
Fanucci E; Fiaschetti V; Rotili A; Floris R; Simonetti G
Emerg Radiol; 2007 Feb; 13(5):251-7. PubMed ID: 17180674
[TBL] [Abstract][Full Text] [Related]
19. Whole body CT versus selective radiological imaging strategy in trauma: an evidence-based clinical review.
Long B; April MD; Summers S; Koyfman A
Am J Emerg Med; 2017 Sep; 35(9):1356-1362. PubMed ID: 28366287
[TBL] [Abstract][Full Text] [Related]
20. Rapid imaging protocol in trauma: a whole-body dual-source CT scan.
Sedlic A; Chingkoe CM; Tso DK; Galea-Soler S; Nicolaou S
Emerg Radiol; 2013 Oct; 20(5):401-8. PubMed ID: 23793476
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]