These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

203 related articles for article (PubMed ID: 30422336)

  • 21. Biomechanical Comparison of Use of Two Screws versus Three Screws Per Fragment with Locking Plate Constructs under Cyclic Loading in Compression in a Fracture Gap Model.
    Palierne S; Blondel M; Swider P; Autefage A
    Vet Comp Orthop Traumatol; 2022 May; 35(3):166-174. PubMed ID: 35272366
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Biomechanical evaluation of a locking and nonlocking reconstruction plate in an osteoporotic calcaneal fracture model.
    Blake MH; Owen JR; Sanford TS; Wayne JS; Adelaar RS
    Foot Ankle Int; 2011 Apr; 32(4):432-6. PubMed ID: 21733448
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Can locking screws allow smaller, low-profile plates to achieve comparable stability to larger, standard plates?
    Garrigues GE; Glisson RR; Garrigues NW; Richard MJ; Ruch DS
    J Orthop Trauma; 2011 Jun; 25(6):347-54. PubMed ID: 21577070
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Mechanical Evaluation of Locking, Nonlocking, and Hybrid Plating Constructs Using a Locking Compression Plate in a Canine Synthetic Bone Model.
    Rowe-Guthrie KM; Markel MD; Bleedorn JA
    Vet Surg; 2015 Oct; 44(7):838-42. PubMed ID: 26287445
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Feline ilial fractures: assessment of screw loosening and pelvic canal narrowing after lateral plating.
    Hamilton MH; Evans DA; Langley-Hobbs SJ
    Vet Surg; 2009 Apr; 38(3):326-33. PubMed ID: 19573095
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Mechanical characteristics of locking and compression plate constructs applied dorsally to distal radius fractures.
    Boswell S; McIff TE; Trease CA; Toby EB
    J Hand Surg Am; 2007; 32(5):623-9. PubMed ID: 17481999
    [TBL] [Abstract][Full Text] [Related]  

  • 27. In vitro biomechanical testing of the 3.5 mm LCP in torsion: a comparison of unicortical locking to bicortical nonlocking screws placed nearest the fracture gap.
    Padron AA; Owen JR; Wayne JS; Aktay SA; Barnes RF
    BMC Res Notes; 2017 Dec; 10(1):768. PubMed ID: 29282136
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A biomechanical comparison of locking and nonlocking plates for the fixation of calcaneal fractures.
    Redfern DJ; Oliveira ML; Campbell JT; Belkoff SM
    Foot Ankle Int; 2006 Mar; 27(3):196-201. PubMed ID: 16539902
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A biomechanical comparison of external skeletal fixation and plating for the stabilization of ilial osteotomies in dogs.
    Fitzpatrick N; Lewis D; Cross A
    Vet Comp Orthop Traumatol; 2008; 21(4):349-57. PubMed ID: 18704242
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Biomechanical Comparison of Bicortical, Unicortical, and Unicortical Far-Cortex-Abutting Screw Fixations in Plated Comminuted Midshaft Clavicle Fractures.
    Croley JS; Morris RP; Amin A; Lindsey RW; Gugala Z
    J Hand Surg Am; 2016 Jun; 41(6):703-11. PubMed ID: 27113909
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Biomechanical comparison of 4 different lateral plate constructs for distal fibula fractures.
    Eckel TT; Glisson RR; Anand P; Parekh SG
    Foot Ankle Int; 2013 Nov; 34(11):1588-95. PubMed ID: 23818460
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Ex vivo cyclic mechanical behaviour of 2.4 mm locking plates compared with 2.4 mm limited contact plates in a cadaveric diaphyseal gap model.
    Irubetagoyena I; Verset M; Palierne S; Swider P; Autefage A
    Vet Comp Orthop Traumatol; 2013; 26(6):479-88. PubMed ID: 24080774
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Biomechanical comparison of bicortical locking versus unicortical far-cortex-abutting locking screw-plate fixation for comminuted radial shaft fractures.
    Overturf SJ; Morris RP; Gugala Z; Lindsey RW
    J Hand Surg Am; 2014 Oct; 39(10):1907-13. PubMed ID: 25149898
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A biomechanical comparison of one-third tubular plates versus periarticular plates for fixation of osteoporotic distal fibula fractures.
    Davis AT; Israel H; Cannada LK; Bledsoe JG
    J Orthop Trauma; 2013 Sep; 27(9):e201-7. PubMed ID: 23249893
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Locking plates in osteoporosis: a biomechanical cadaveric study of diaphyseal humerus fractures.
    Davis C; Stall A; Knutsen E; Whitney A; Becker E; Hsieh AH; OʼToole RV
    J Orthop Trauma; 2012 Apr; 26(4):216-21. PubMed ID: 22068207
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Ex Vivo Biomechanical Comparison of Titanium Locking Plate, Stainless Steel Nonlocking Plate, and Tie-in External Fixator Applied by a Dorsal Approach on Ostectomized Humeri of Pigeons (
    Darrow BG; Weigel JP; Greenacre CB; Xie X; Liaw PK; Biskup JJ
    J Avian Med Surg; 2019 Mar; 33(1):29-37. PubMed ID: 31124609
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Is implant choice associated with fixation strength for displaced radial neck fracture: a network meta-analysis of biomechanical studies.
    Su YC; Wang YY; Fang CJ; Su WR; Kuan FC; Hsu KL; Hong CK; Yeh ML; Lin CJ; Tu YK; Shih CA
    Sci Rep; 2023 Apr; 13(1):6891. PubMed ID: 37105993
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Biomechanical evaluation of locking versus nonlocking 2.0-mm malleable L-miniplate fixation of simulated caudal mandibular fractures in cats.
    Kot CCS; Verstraete FJM; Garcia TC; Stover SM; Arzi B
    Am J Vet Res; 2022 Jun; 83(8):. PubMed ID: 35895785
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Volar fixed-angle plating of distal radius fractures: screws versus pegs--a biomechanical study in a cadaveric model.
    Mehling I; Klitscher D; Mehling AP; Nowak TE; Sternstein W; Rommens PM; Müller LP
    J Orthop Trauma; 2012 Jul; 26(7):395-401. PubMed ID: 22011636
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Biomechanical comparison of mono- and bicortical screws in an experimentally induced gap fracture.
    Demner D; Garcia TC; Serdy MG; Hayashi K; Nir BA; Stover SM
    Vet Comp Orthop Traumatol; 2014; 27(6):422-9. PubMed ID: 25327936
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.