These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

247 related articles for article (PubMed ID: 30424135)

  • 1. Recent Microdevice-Based Aptamer Sensors.
    Mazaafrianto DN; Maeki M; Ishida A; Tani H; Tokeshi M
    Micromachines (Basel); 2018 Apr; 9(5):. PubMed ID: 30424135
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Application of Electrochemical Aptasensors toward Clinical Diagnostics, Food, and Environmental Monitoring: Review.
    Li Z; Mohamed MA; Vinu Mohan AM; Zhu Z; Sharma V; Mishra GK; Mishra RK
    Sensors (Basel); 2019 Dec; 19(24):. PubMed ID: 31835479
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Aptamer-based nanobiosensors.
    Kim YS; Raston NH; Gu MB
    Biosens Bioelectron; 2016 Feb; 76():2-19. PubMed ID: 26139320
    [TBL] [Abstract][Full Text] [Related]  

  • 4. FFF-based high-throughput sequence shortlisting to support the development of aptamer-based analytical strategies.
    Marassi V; Mattarozzi M; Toma L; Giordani S; Ronda L; Roda B; Zattoni A; Reschiglian P; Careri M
    Anal Bioanal Chem; 2022 Jul; 414(18):5519-5527. PubMed ID: 35182166
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Detection of pathogenic bacteria via nanomaterials-modified aptasensors.
    Sharifi S; Vahed SZ; Ahmadian E; Dizaj SM; Eftekhari A; Khalilov R; Ahmadi M; Hamidi-Asl E; Labib M
    Biosens Bioelectron; 2020 Feb; 150():111933. PubMed ID: 31818764
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Recent Advances in the Selection of Cancer-Specific Aptamers for the Development of Biosensors.
    Sousa DA; Carneiro M; Ferreira D; Moreira FTC; Sales MGF; Rodrigues LR
    Curr Med Chem; 2022; 29(37):5850-5880. PubMed ID: 35209816
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Aptamers Targeting Membrane Proteins for Sensor and Diagnostic Applications.
    Kara N; Ayoub N; Ilgu H; Fotiadis D; Ilgu M
    Molecules; 2023 Apr; 28(9):. PubMed ID: 37175137
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Capture-SELEX: Selection Strategy, Aptamer Identification, and Biosensing Application.
    Lam SY; Lau HL; Kwok CK
    Biosensors (Basel); 2022 Dec; 12(12):. PubMed ID: 36551109
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Voltammetric aptasensors for protein disease biomarkers detection: A review.
    Meirinho SG; Dias LG; Peres AM; Rodrigues LR
    Biotechnol Adv; 2016; 34(5):941-953. PubMed ID: 27235188
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Generating aptamers by cell-SELEX for applications in molecular medicine.
    Ye M; Hu J; Peng M; Liu J; Liu J; Liu H; Zhao X; Tan W
    Int J Mol Sci; 2012; 13(3):3341-3353. PubMed ID: 22489154
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Integrated microfluidic system for rapid screening of CRP aptamers utilizing systematic evolution of ligands by exponential enrichment (SELEX).
    Huang CJ; Lin HI; Shiesh SC; Lee GB
    Biosens Bioelectron; 2010 Mar; 25(7):1761-6. PubMed ID: 20061133
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Aptamers: The Powerful Molecular Tools for Virus Detection.
    Han C; Li Q; Ji H; Xing W; Zhang L; Zhang L
    Chem Asian J; 2021 Jun; 16(11):1298-1306. PubMed ID: 33851522
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Electronic aptamer-based sensors.
    Willner I; Zayats M
    Angew Chem Int Ed Engl; 2007; 46(34):6408-18. PubMed ID: 17600802
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Nucleic Acid Aptamer-Based Biosensors: A Review.
    Sequeira-Antunes B; Ferreira HA
    Biomedicines; 2023 Dec; 11(12):. PubMed ID: 38137422
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An on-chip Cell-SELEX process for automatic selection of high-affinity aptamers specific to different histologically classified ovarian cancer cells.
    Hung LY; Wang CH; Hsu KF; Chou CY; Lee GB
    Lab Chip; 2014 Oct; 14(20):4017-28. PubMed ID: 25144781
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Lab-on-a-Chip Systems for Aptamer-Based Biosensing.
    Khan NI; Song E
    Micromachines (Basel); 2020 Feb; 11(2):. PubMed ID: 32093323
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Screening of aptamers on microfluidic systems for clinical applications.
    Weng CH; Huang CJ; Lee GB
    Sensors (Basel); 2012; 12(7):9514-29. PubMed ID: 23012556
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Gold nanoparticle-assisted SELEX as a visual monitoring platform for the development of small molecule-binding DNA aptasensors.
    Lee ES; Kim EJ; Park TK; Bae DW; Cha SS; Kim TW; Kim YP
    Biosens Bioelectron; 2021 Nov; 191():113468. PubMed ID: 34233257
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A new cognate aptamer pair-based sandwich-type electrochemical biosensor for sensitive detection of Staphylococcus aureus.
    Nguyen TT; Kim ER; Gu MB
    Biosens Bioelectron; 2022 Feb; 198():113835. PubMed ID: 34847360
    [TBL] [Abstract][Full Text] [Related]  

  • 20. "Fitting" makes "sensing" simple: label-free detection strategies based on nucleic acid aptamers.
    Du Y; Li B; Wang E
    Acc Chem Res; 2013 Feb; 46(2):203-13. PubMed ID: 23214491
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.