These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
77 related articles for article (PubMed ID: 3042633)
1. Regulation of pneumatic total artificial heart function: a review. Deleuze PH; Riebman JB; De Paulis R; Olsen DB; Loisance DY Int J Artif Organs; 1988 May; 11(3):147-52. PubMed ID: 3042633 [No Abstract] [Full Text] [Related]
2. A new automatic cardiac output control algorithm for moving actuator total artificial heart by motor current waveform analysis. Choi WW; Kim HC; Min BG Int J Artif Organs; 1996 Mar; 19(3):189-96. PubMed ID: 8675364 [TBL] [Abstract][Full Text] [Related]
3. Fuzzy logic automatic control of the Phoenix-7 total artificial heart. Hsu CH J Artif Organs; 2004; 7(2):69-76. PubMed ID: 15309673 [TBL] [Abstract][Full Text] [Related]
4. Diagnostic monitoring and drive system management of patients with total artificial heart. Mays JB; Williams MA; Barker LE; Hastings WL; DeVries WC Heart Lung; 1986 Sep; 15(5):466-75. PubMed ID: 3639075 [No Abstract] [Full Text] [Related]
5. In vitro testing of a new driver for the pneumatic total artificial heart with inherent cardiac output measuring system. Frumento CI; Auch WD; Frumento AS Med Prog Technol; 1983-1984; 10(2):97-107. PubMed ID: 6674739 [TBL] [Abstract][Full Text] [Related]
6. Control and driving of pneumatic total artificial hearts TNS-BRNO-II and -III in long-term experiments. Vasků J; Urbánek P; Vasků J; Cerný J; Smutný M; Urbánek E; Suchánek J; Gregor Z; Dostál M; Guba P Artif Organs; 1986 Apr; 10(2):145-52. PubMed ID: 3718275 [TBL] [Abstract][Full Text] [Related]
7. A cardiac output monitor and diagnostic unit for pneumatically driven artificial hearts. Willshaw P; Nielsen SD; Nanas J; Pichel RH; Olsen DB Artif Organs; 1984 May; 8(2):215-9. PubMed ID: 6233957 [TBL] [Abstract][Full Text] [Related]
8. Determination of cardiac output of the artificial heart from the drive air flow. Hanzelka P; Vasků J; Urbánek P; Vasků J; Urbánek E Artif Organs; 1979 Aug; 3(3):277-8. PubMed ID: 161167 [TBL] [Abstract][Full Text] [Related]
9. Right-left ventricular output balance in the totally implantable artificial heart. Olsen DB; White RK; Long JW; Khanwilkar PS Int J Artif Organs; 1991 Jun; 14(6):359-64. PubMed ID: 1885244 [TBL] [Abstract][Full Text] [Related]
10. Determining arterial pressure, left atrial pressure and cardiac output from the left pneumatic drive line of the total artificial heart. Rosenberg G; Landis DL; Phillips WM; Stallsmith J; Pierce WS Trans Am Soc Artif Intern Organs; 1978; 24():341-4. PubMed ID: 362675 [TBL] [Abstract][Full Text] [Related]
11. Cardiac output requirements and maximum dimensions for a neonate total artificial heart. Koppert E; Pantalos GM; Tieleman R; Swier P; Burns GL Int J Artif Organs; 1991 Nov; 14(11):707-15. PubMed ID: 1757158 [TBL] [Abstract][Full Text] [Related]
12. In vitro analysis of an atrial shunt in balancing an electrohydraulic total artificial heart. Crump KR; Khanwilkar PS; Long JW; Holfert JW; Olsen DB ASAIO Trans; 1990; 36(3):M254-7. PubMed ID: 2252671 [TBL] [Abstract][Full Text] [Related]
15. Effects of a total artificial heart right stroke volume limiter on left-right hemodynamic balance. Fukamachi K; Massiello AL; Kiraly RJ; Chen JF; Himley S; Davies C; Fukumura F; Muramoto K; Olsen E; Golding LA ASAIO J; 1993; 39(3):M410-4. PubMed ID: 8268568 [TBL] [Abstract][Full Text] [Related]
16. Studies with the total artificial heart using sheep as an adult animal model. Hamanaka Y Hiroshima J Med Sci; 1985 Jun; 34(2):215-46. PubMed ID: 4030386 [No Abstract] [Full Text] [Related]
17. Management of a malfunctioning left ventricle in an artificial heart. Gaykowski R; Blaylock RC; Murray KD; Nielsen SD; Olsen DB J Heart Transplant; 1985 Feb; 4(2):259-62. PubMed ID: 3843611 [TBL] [Abstract][Full Text] [Related]
18. Control of cardiac replacement. Rosenberg G ASAIO Trans; 1986; 32(2):624-8. PubMed ID: 3801225 [No Abstract] [Full Text] [Related]
19. Volume compensation for pulsatile blood pumps. Whalen RL; Snow JL; Harasaki H; Nosé Y Trans Am Soc Artif Intern Organs; 1981; 27():110-5. PubMed ID: 7331062 [No Abstract] [Full Text] [Related]
20. Development of the E4T electrohydraulic total artificial heart. Himley SC; Butler KC; Massiello A; Chen J; Irie H; Harasaki H; Kiraly RJ; Golding L; Takatani S; Nosé Y ASAIO Trans; 1990; 36(3):M234-7. PubMed ID: 2252665 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]