593 related articles for article (PubMed ID: 30439535)
1. Comparison of suture button fixation and syndesmotic screw fixation in the treatment of distal tibiofibular syndesmosis injury: A systematic review and meta-analysis.
Xie L; Xie H; Wang J; Chen C; Zhang C; Chen H; Zheng W
Int J Surg; 2018 Dec; 60():120-131. PubMed ID: 30439535
[TBL] [Abstract][Full Text] [Related]
2. A systematic review of suture-button versus syndesmotic screw in the treatment of distal tibiofibular syndesmosis injury.
Zhang P; Liang Y; He J; Fang Y; Chen P; Wang J
BMC Musculoskelet Disord; 2017 Jul; 18(1):286. PubMed ID: 28676078
[TBL] [Abstract][Full Text] [Related]
3. Evaluation of Reduction Accuracy of Suture-Button and Screw Fixation Techniques for Syndesmotic Injuries.
Kocadal O; Yucel M; Pepe M; Aksahin E; Aktekin CN
Foot Ankle Int; 2016 Dec; 37(12):1317-1325. PubMed ID: 27535086
[TBL] [Abstract][Full Text] [Related]
4. The Clinical Efficacy of Suture-Button Fixation and Trans-Syndesmotic Screw Fixation in the Treatment of Ankle Fracture Combined With Distal Tibiofibular Syndesmosis Injury: A Retrospective Study.
Xu Y; Kang R; Li M; Li Z; Ma T; Ren C; Wang Q; Lu Y; Zhang K
J Foot Ankle Surg; 2022; 61(1):143-148. PubMed ID: 34404589
[TBL] [Abstract][Full Text] [Related]
5. Arthroscopically measured syndesmotic stability after screw vs. suture button fixation in a cadaveric model.
Lubberts B; Vopat BG; Wolf JC; Longo UG; DiGiovanni CW; Guss D
Injury; 2017 Nov; 48(11):2433-2437. PubMed ID: 28899558
[TBL] [Abstract][Full Text] [Related]
6. [TREATMENT OF PRONATION EXTERNAL ROTATION ANKLE FRACTURE COMBINED WITH SEPARATION OF DISTAL TIBIOFIBULAR SYNDESMOSIS].
Wu B; Ding Z; Huang G; Liu G; Cai Z; Ding L; Li X
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2016 Sep; 30(9):1081-1084. PubMed ID: 29786359
[TBL] [Abstract][Full Text] [Related]
7. Lower complication rate and faster return to sports in patients with acute syndesmotic rupture treated with a new knotless suture button device.
Colcuc C; Blank M; Stein T; Raimann F; Weber-Spickschen S; Fischer S; Hoffmann R
Knee Surg Sports Traumatol Arthrosc; 2018 Oct; 26(10):3156-3164. PubMed ID: 29224059
[TBL] [Abstract][Full Text] [Related]
8. A Systematic Review and Meta-Analysis on Treatment of Ankle Fractures With Syndesmotic Rupture: Suture-Button Fixation Versus Cortical Screw Fixation.
McKenzie AC; Hesselholt KE; Larsen MS; Schmal H
J Foot Ankle Surg; 2019 Sep; 58(5):946-953. PubMed ID: 31474406
[TBL] [Abstract][Full Text] [Related]
9. Comparison of Suture-Button Versus Syndesmotic Screw in the Treatment of Distal Tibiofibular Syndesmosis Injury: A Meta-analysis.
Xu K; Zhang J; Zhang P; Liang Y; Hu JL; Wang X; Wang J
J Foot Ankle Surg; 2021; 60(3):555-566. PubMed ID: 33518505
[TBL] [Abstract][Full Text] [Related]
10. Acute distal tibiofibular syndesmosis injury: a systematic review of suture-button versus syndesmotic screw repair.
Schepers T
Int Orthop; 2012 Jun; 36(6):1199-206. PubMed ID: 22318415
[TBL] [Abstract][Full Text] [Related]
11. Suture Button Versus Syndesmotic Screw for Syndesmosis Injuries: A Meta-analysis of Randomized Controlled Trials.
Shimozono Y; Hurley ET; Myerson CL; Murawski CD; Kennedy JG
Am J Sports Med; 2019 Sep; 47(11):2764-2771. PubMed ID: 30475639
[TBL] [Abstract][Full Text] [Related]
12. Self-made wire-rope button plate: A novel option for the treatment of distal tibiofibular syndesmosis separation.
Wei XK; Jing GW; Shu Y; Tong J; Wang JH
J Orthop Surg (Hong Kong); 2021; 29(1):2309499020975215. PubMed ID: 33557688
[TBL] [Abstract][Full Text] [Related]
13. Fate of the syndesmotic screw--Search for a prudent solution.
Kaftandziev I; Spasov M; Trpeski S; Zafirova-Ivanovska B; Bakota B
Injury; 2015 Nov; 46 Suppl 6():S125-9. PubMed ID: 26582218
[TBL] [Abstract][Full Text] [Related]
14. A comparison of double single suture-button fixation, suture-button fixation, and screw fixation for ankle syndesmosis injury: A retrospective cohort study.
Kurtoglu A; Kochai A; Inanmaz ME; Sukur E; Keskin D; Türker M; Uysal M; Sen Z; Daldal I
Medicine (Baltimore); 2021 Apr; 100(13):e25328. PubMed ID: 33787628
[TBL] [Abstract][Full Text] [Related]
15. Effectiveness of suture button fixation versus screw fixation for the management of acute distal tibiofibular syndesmotic injuries: a systematic review protocol.
Cehic MG; Jaarsma R; Whitehorn A
JBI Evid Synth; 2023 May; 21(5):977-984. PubMed ID: 36602286
[TBL] [Abstract][Full Text] [Related]
16. Technical aspects of the syndesmotic screw and their effect on functional outcome following acute distal tibiofibular syndesmosis injury.
Schepers T; van der Linden H; van Lieshout EM; Niesten DD; van der Elst M
Injury; 2014 Apr; 45(4):775-9. PubMed ID: 24139172
[TBL] [Abstract][Full Text] [Related]
17. Biomechanical Analysis of a Novel Syndesmotic Plate Compared With Traditional Screw and Suture Button Fixation.
Weng Q; Lin C; Liu Y; Dai G; Lutchooman V; Hong J
J Foot Ankle Surg; 2020; 59(3):522-528. PubMed ID: 31864842
[TBL] [Abstract][Full Text] [Related]
18. Injury mechanism affects the stability of suture-button syndesmosis fixation.
Chen KH; Chen CH; Huang YM; Lee HH; Tsuang YH
J Orthop Surg Res; 2020 Dec; 15(1):599. PubMed ID: 33302992
[TBL] [Abstract][Full Text] [Related]
19. Suture-button versus screw fixation of the syndesmosis: a biomechanical analysis.
Klitzman R; Zhao H; Zhang LQ; Strohmeyer G; Vora A
Foot Ankle Int; 2010 Jan; 31(1):69-75. PubMed ID: 20067726
[TBL] [Abstract][Full Text] [Related]
20. Cost-Effectiveness Analysis of Syndesmotic Screw Versus Suture Button Fixation in Tibiofibular Syndesmotic Injuries.
Ramsey DC; Friess DM
J Orthop Trauma; 2018 Jun; 32(6):e198-e203. PubMed ID: 29521685
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]