126 related articles for article (PubMed ID: 30441199)
41. Electronic health record nested pragmatic randomized controlled trial of a reminder system for serum lithium level monitoring in patients with mood disorder: KONOTORI study protocol.
Seki T; Aki M; Kawashima H; Miki T; Tanaka S; Kawakami K; Furukawa TA
Trials; 2019 Dec; 20(1):706. PubMed ID: 31829279
[TBL] [Abstract][Full Text] [Related]
42. Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis.
Gao W; Emaminejad S; Nyein HYY; Challa S; Chen K; Peck A; Fahad HM; Ota H; Shiraki H; Kiriya D; Lien DH; Brooks GA; Davis RW; Javey A
Nature; 2016 Jan; 529(7587):509-514. PubMed ID: 26819044
[TBL] [Abstract][Full Text] [Related]
43. Extremely Fast Self-Healable Bio-Based Supramolecular Polymer for Wearable Real-Time Sweat-Monitoring Sensor.
Yoon JH; Kim SM; Eom Y; Koo JM; Cho HW; Lee TJ; Lee KG; Park HJ; Kim YK; Yoo HJ; Hwang SY; Park J; Choi BG
ACS Appl Mater Interfaces; 2019 Dec; 11(49):46165-46175. PubMed ID: 31774642
[TBL] [Abstract][Full Text] [Related]
44. The Optimization of Analog Front-End for Fully Integrated Wearable Sweat Sensor.
Kim I; Jin H; Jiang Y; Qin Y
Annu Int Conf IEEE Eng Med Biol Soc; 2019 Jul; 2019():1123-1126. PubMed ID: 31946091
[TBL] [Abstract][Full Text] [Related]
45. Development and evaluation of the simultaneous determination of sweat sodium and chloride by ion-selective electrodes.
Barbour HM
Ann Clin Biochem; 1991 Mar; 28 ( Pt 2)():150-4. PubMed ID: 1859152
[TBL] [Abstract][Full Text] [Related]
46. Appropriateness of therapeutic drug monitoring for lithium.
Ratanajamit C; Soorapan S; Doang-ngern T; Waenwaisart W; Suwanchavalit L; Suwansiri S; Jantasaro S; Yanate I
J Med Assoc Thai; 2006 Nov; 89(11):1954-60. PubMed ID: 17205880
[TBL] [Abstract][Full Text] [Related]
47. Nonenzymatic Wearable Sensor for Electrochemical Analysis of Perspiration Glucose.
Zhu X; Ju Y; Chen J; Liu D; Liu H
ACS Sens; 2018 Jun; 3(6):1135-1141. PubMed ID: 29767510
[TBL] [Abstract][Full Text] [Related]
48. A Capillary-Evaporation Micropump for Real-Time Sweat Rate Monitoring with an Electrochemical Sensor.
Chen XM; Li YJ; Han D; Zhu HC; Xue CD; Chui HC; Cao T; Qin KR
Micromachines (Basel); 2019 Jul; 10(7):. PubMed ID: 31284628
[TBL] [Abstract][Full Text] [Related]
49. Multifunctional Nickel Phosphate Nano/Microflakes 3D Electrode for Electrochemical Energy Storage, Nonenzymatic Glucose, and Sweat pH Sensors.
Padmanathan N; Shao H; Razeeb KM
ACS Appl Mater Interfaces; 2018 Mar; 10(10):8599-8610. PubMed ID: 29460624
[TBL] [Abstract][Full Text] [Related]
50. Electrochemical Detection and Quantification of Lithium Ions in Authentic Human Saliva Using LiMn
Suherman AL; Rasche B; Godlewska B; Nicholas P; Herlihy S; Caiger N; Cowen PJ; Compton RG
ACS Sens; 2019 Sep; 4(9):2497-2506. PubMed ID: 31429259
[TBL] [Abstract][Full Text] [Related]
51. Environmentally Friendly Manufacturing of Flexible Graphite Electrodes for a Wearable Device Monitoring Zinc in Sweat.
Dias AA; Chagas CLS; Silva-Neto HA; Lobo-Junior EO; Sgobbi LF; de Araujo WR; Paixão TRLC; Coltro WKT
ACS Appl Mater Interfaces; 2019 Oct; 11(43):39484-39492. PubMed ID: 31524381
[TBL] [Abstract][Full Text] [Related]
52. Lithium therapy.
Dodds G
Scott Med J; 2000 Dec; 45(6):171-3. PubMed ID: 11216307
[TBL] [Abstract][Full Text] [Related]
53. Sweat Biomarker Sensor Incorporating Picowatt, Three-Dimensional Extended Metal Gate Ion Sensitive Field Effect Transistors.
Zhang J; Rupakula M; Bellando F; Garcia Cordero E; Longo J; Wildhaber F; Herment G; Guérin H; Ionescu AM
ACS Sens; 2019 Aug; 4(8):2039-2047. PubMed ID: 31282146
[TBL] [Abstract][Full Text] [Related]
54. 50 Years with lithium treatment in affective disorders: present problems and priorities.
Vestergaard P; Licht RW
World J Biol Psychiatry; 2001 Jan; 2(1):18-26. PubMed ID: 12587181
[TBL] [Abstract][Full Text] [Related]
55. Tattoo-based potentiometric ion-selective sensors for epidermal pH monitoring.
Bandodkar AJ; Hung VW; Jia W; Valdés-Ramírez G; Windmiller JR; Martinez AG; Ramírez J; Chan G; Kerman K; Wang J
Analyst; 2013 Jan; 138(1):123-8. PubMed ID: 23113321
[TBL] [Abstract][Full Text] [Related]
56. Wearable Fluid Capture Devices for Electrochemical Sensing of Sweat.
Li G; Mo X; Law WC; Chan KC
ACS Appl Mater Interfaces; 2019 Jan; 11(1):238-243. PubMed ID: 30516364
[TBL] [Abstract][Full Text] [Related]
57. Stretchable, wireless sensors and functional substrates for epidermal characterization of sweat.
Huang X; Liu Y; Chen K; Shin WJ; Lu CJ; Kong GW; Patnaik D; Lee SH; Cortes JF; Rogers JA
Small; 2014 Aug; 10(15):3083-90. PubMed ID: 24706477
[TBL] [Abstract][Full Text] [Related]
58. Wearable Sensors for Biochemical Sweat Analysis.
Bandodkar AJ; Jeang WJ; Ghaffari R; Rogers JA
Annu Rev Anal Chem (Palo Alto Calif); 2019 Jun; 12(1):1-22. PubMed ID: 30786214
[TBL] [Abstract][Full Text] [Related]
59. A Wearable Electrochemical Platform for Noninvasive Simultaneous Monitoring of Ca(2+) and pH.
Nyein HY; Gao W; Shahpar Z; Emaminejad S; Challa S; Chen K; Fahad HM; Tai LC; Ota H; Davis RW; Javey A
ACS Nano; 2016 Jul; 10(7):7216-24. PubMed ID: 27380446
[TBL] [Abstract][Full Text] [Related]
60. Saliva lithium: a poor predictor of plasma and erythrocyte levels.
McKeage MJ; Maling TJ
N Z Med J; 1989 Oct; 102(878):559-60. PubMed ID: 2812583
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]