  • 1. An air-assisted flow-gating interface for capillary electrophoresis.
    Opekar F; Tůma P
    Electrophoresis; 2019 Feb; 40(4):587-590. PubMed ID: 30443942
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Characterization of various geometric arrangements of "air-assisted" flow gating interfaces for capillary electrophoresis.
    Opekar F; Tůma P
    Electrophoresis; 2021 Mar; 42(6):749-755. PubMed ID: 33191565
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dialysis of one sample drop on-line connected with electrophoresis in short capillary.
    Opekar F; Tůma P
    Talanta; 2020 Nov; 219():121252. PubMed ID: 32887143
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Micro-injector for capillary electrophoresis.
    Sáiz J; Koenka IJ; García-Ruiz C; Müller B; Chwalek T; Hauser PC
    Electrophoresis; 2015 Aug; 36(16):1941-4. PubMed ID: 25752271
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Coaxial flow-gating interface for capillary electrophoresis.
    Opekar F; Tůma P
    J Sep Sci; 2017 Aug; 40(15):3138-3143. PubMed ID: 28581040
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Hydrodynamic sample injection into short electrophoretic capillary in systems with a flow-gating interface.
    Opekar F; Tůma P
    J Chromatogr A; 2017 Jan; 1480():93-98. PubMed ID: 27993397
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Injection system for fast capillary electrophoresis based on pressure regulation with flow restrictors.
    Furter JS; Hauser PC
    Electrophoresis; 2019 Feb; 40(3):410-413. PubMed ID: 30152034
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Direct sample injection from a syringe needle into a separation capillary.
    Opekar F; Tůma P
    Anal Chim Acta; 2018 Dec; 1042():133-140. PubMed ID: 30428980
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dual-channel capillary electrophoresis for simultaneous determination of cations and anions.
    Opekar F; Tůma P
    J Chromatogr A; 2016 May; 1446():158-63. PubMed ID: 27083255
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Application of a capillary-assembled microfluidic system for separation of cephalosporins.
    Koczka PI; Gaspar A
    Electrophoresis; 2014 Sep; 35(17):2534-7. PubMed ID: 24789628
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Advances in on-line enzyme assays by sequence analysis-based capillary electrophoresis].
    Tian M; Yang L
    Se Pu; 2020 Oct; 38(10):1143-1153. PubMed ID: 34213111
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Microfabricated liquid junction hybrid capillary electrophoresis-mass spectrometry interface for fully automated operation.
    Krenkova J; Kleparnik K; Luksch J; Foret F
    Electrophoresis; 2019 Sep; 40(18-19):2263-2270. PubMed ID: 30794321
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Progress in on-line, at-line, and in-line coupling of sample treatment with capillary and microchip electrophoresis over the past 10 years: A review.
    Tůma P
    Anal Chim Acta; 2023 Jun; 1261():341249. PubMed ID: 37147053
    [TBL] [Abstract][Full Text] [Related]  

  • 14. On-line simultaneous and rapid separation of anions and cations from a single sample using dual-capillary sequential injection-capillary electrophoresis.
    Gaudry AJ; Guijt RM; Macka M; Hutchinson JP; Johns C; Hilder EF; Dicinoski GW; Nesterenko PN; Haddad PR; Breadmore MC
    Anal Chim Acta; 2013 Jun; 781():80-7. PubMed ID: 23684468
    [TBL] [Abstract][Full Text] [Related]  

  • 15. High performance microfluidic capillary electrophoresis devices.
    Fu LM; Leong JC; Lin CF; Tai CH; Tsai CH
    Biomed Microdevices; 2007 Jun; 9(3):405-12. PubMed ID: 17487587
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Simplifying CE-MS operation. 2. Interfacing low-flow separation techniques to mass spectrometry using a porous tip.
    Moini M
    Anal Chem; 2007 Jun; 79(11):4241-6. PubMed ID: 17447730
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A flow injection-capillary electrophoresis system with high-voltage contactless conductivity detection for automated dual opposite end injection.
    Kubán P; Kubán P; Hauser PC; Kubán V
    Electrophoresis; 2004 Jan; 25(1):35-42. PubMed ID: 14730566
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Microfluidic picoliter-scale translational spontaneous sample introduction for high-speed capillary electrophoresis.
    Zhang T; Fang Q; Du WB; Fu JL
    Anal Chem; 2009 May; 81(9):3693-8. PubMed ID: 19351143
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Electrokinetic injection of samples into a short electrophoretic capillary controlled by piezoelectric micropumps.
    Opekar F; Nesměrák K; Tůma P
    Electrophoresis; 2016 Feb; 37(4):595-600. PubMed ID: 26617312
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An automated electrokinetic continuous sample introduction system for microfluidic chip-based capillary electrophoresis.
    He QH; Fang Q; Du WB; Huang YZ; Fang ZL
    Analyst; 2005 Jul; 130(7):1052-8. PubMed ID: 15965529
    [TBL] [Abstract][Full Text] [Related]  