These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
798 related articles for article (PubMed ID: 30444315)
1. Home blood pressure control status in 2017-2018 for hypertension specialist centers in Asia: Results of the Asia BP@Home study. Kario K; Tomitani N; Buranakitjaroen P; Chia YC; Park S; Chen CH; Divinagracia R; Shin J; Siddique S; Sison J; Ann Soenarta A; Sogunuru GP; Tay JC; Turana Y; Zhang Y; Nailes J; Wanthong S; Hoshide S; Matsushita N; Kanegae H; Wang JG; J Clin Hypertens (Greenwich); 2018 Dec; 20(12):1686-1695. PubMed ID: 30444315 [TBL] [Abstract][Full Text] [Related]
2. Prevalence of ambulatory blood pressure phenotypes using the 2017 American College of Cardiology/American Heart Association blood pressure guideline thresholds: data from the Coronary Artery Risk Development in Young Adults study. Poudel B; Booth JN; Sakhuja S; Moran AE; Schwartz JE; Lloyd-Jones DM; Lewis CE; Shikany JM; Shimbo D; Muntner P J Hypertens; 2019 Jul; 37(7):1401-1410. PubMed ID: 31145711 [TBL] [Abstract][Full Text] [Related]
3. Expert panel consensus recommendations for ambulatory blood pressure monitoring in Asia: The HOPE Asia Network. Kario K; Shin J; Chen CH; Buranakitjaroen P; Chia YC; Divinagracia R; Nailes J; Hoshide S; Siddique S; Sison J; Soenarta AA; Sogunuru GP; Tay JC; Teo BW; Turana Y; Zhang Y; Park S; Van Minh H; Wang JG J Clin Hypertens (Greenwich); 2019 Sep; 21(9):1250-1283. PubMed ID: 31532913 [TBL] [Abstract][Full Text] [Related]
4. Rationale and design for the Asia BP@Home study on home blood pressure control status in 12 Asian countries and regions. Kario K; Tomitani N; Buranakitjaroen P; Chen CH; Chia YC; Divinagracia R; Park S; Shin J; Siddique S; Sison J; Soenarta AA; Sogunuru GP; Tay JC; Turana Y; Wang JG; Wong L; Zhang Y; Wanthong S; Hoshide S; Kanegae H; J Clin Hypertens (Greenwich); 2018 Jan; 20(1):33-38. PubMed ID: 29265725 [TBL] [Abstract][Full Text] [Related]
5. Diagnostic Performance of Office versus Ambulatory Blood Pressure in Kidney Transplant Recipients. Korogiannou M; Sarafidis P; Theodorakopoulou MP; Alexandrou ME; Xagas E; Boletis IN; Marinaki S Am J Nephrol; 2021; 52(7):548-558. PubMed ID: 34311458 [TBL] [Abstract][Full Text] [Related]
6. Proportion of US Adults Recommended Out-of-Clinic Blood Pressure Monitoring According to the 2017 Hypertension Clinical Practice Guidelines. Booth JN; Hubbard D; Sakhuja S; Yano Y; Whelton PK; Wright JT; Shimbo D; Muntner P Hypertension; 2019 Aug; 74(2):399-406. PubMed ID: 31230550 [TBL] [Abstract][Full Text] [Related]
7. Impact of 2017 ACC/AHA hypertension guidelines on the prevalence of white-coat and masked hypertension: A home blood pressure monitoring study. Feitosa ADM; Mota-Gomes MA; Miranda RD; Barroso WS; Barbosa ECD; Pedrosa RP; Oliveira PC; Feitosa CLDM; Lima-Filho JL; Sposito AC; Nadruz W J Clin Hypertens (Greenwich); 2018 Dec; 20(12):1745-1747. PubMed ID: 30378263 [No Abstract] [Full Text] [Related]
8. Prognosis of Masked and White Coat Uncontrolled Hypertension Detected by Ambulatory Blood Pressure Monitoring in Elderly Treated Hypertensive Patients. Pierdomenico SD; Pierdomenico AM; Coccina F; Porreca E Am J Hypertens; 2017 Nov; 30(11):1106-1111. PubMed ID: 29059303 [TBL] [Abstract][Full Text] [Related]
9. Inconsistent Control Status of Office, Home, and Ambulatory Blood Pressure All Taken Using the Same Device: The HI-JAMP Study Baseline Data. Kario K; Hoshide S; Tomitani N; Nishizawa M; Yoshida T; Kabutoya T; Fujiwara T; Mizuno H; Narita K; Komori T; Ogata Y; Suzuki D; Ogoyama Y; Ono A; Yamagiwa K; Abe Y; Nakazato J; Nakagawa N; Katsuya T; Harada N; Kanegae H Am J Hypertens; 2023 Feb; 36(2):90-101. PubMed ID: 36053278 [TBL] [Abstract][Full Text] [Related]
10. Effects of Intensive Versus Standard Office-Based Hypertension Treatment Strategy on White-Coat Effect and Masked Uncontrolled Hypertension: From the SPRINT ABPM Ancillary Study. Ghazi L; Cohen LP; Muntner P; Shimbo D; Drawz PE Hypertension; 2020 Oct; 76(4):1090-1096. PubMed ID: 32829666 [TBL] [Abstract][Full Text] [Related]
11. Impact of miscuffing during home blood pressure measurement on the prevalence of masked hypertension. Mourad JJ; Lopez-Sublet M; Aoun-Bahous S; Villeneuve F; Jaboureck O; Dourmap-Collas C; Denolle T; Fourcade J; Baguet JP Am J Hypertens; 2013 Oct; 26(10):1205-9. PubMed ID: 23727841 [TBL] [Abstract][Full Text] [Related]
12. Accuracy of home versus ambulatory blood pressure monitoring in the diagnosis of white-coat and masked hypertension. Kang YY; Li Y; Huang QF; Song J; Shan XL; Dou Y; Xu XJ; Chen SH; Wang JG J Hypertens; 2015 Aug; 33(8):1580-7. PubMed ID: 26103131 [TBL] [Abstract][Full Text] [Related]
13. Association of Cardiovascular Outcomes With Masked Hypertension Defined by Home Blood Pressure Monitoring in a Japanese General Practice Population. Fujiwara T; Yano Y; Hoshide S; Kanegae H; Kario K JAMA Cardiol; 2018 Jul; 3(7):583-590. PubMed ID: 29800067 [TBL] [Abstract][Full Text] [Related]
15. Is home blood pressure monitoring useful in the management of patients with resistant hypertension? Muxfeldt ES; Barros GS; Viegas BB; Carlos FO; Salles GF Am J Hypertens; 2015 Feb; 28(2):190-9. PubMed ID: 25143267 [TBL] [Abstract][Full Text] [Related]
16. [Influence of blood pressure variability during office visit on the estimation of blood pressure control in treated hypertensive patients]. Villeneuve F; Rosenbaum D; Gury C; Girerd X Ann Cardiol Angeiol (Paris); 2012 Jun; 61(3):198-202. PubMed ID: 22677179 [TBL] [Abstract][Full Text] [Related]