BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

163 related articles for article (PubMed ID: 30456584)

  • 1. CT reconstruction algorithms affect histogram and texture analysis: evidence for liver parenchyma, focal solid liver lesions, and renal cysts.
    Ahn SJ; Kim JH; Lee SM; Park SJ; Han JK
    Eur Radiol; 2019 Aug; 29(8):4008-4015. PubMed ID: 30456584
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of the Impact of Iterative Reconstruction Algorithms on Computed Tomography Texture Features of the Liver Parenchyma Using the Filtration-Histogram Method.
    Sung P; Lee JM; Joo I; Lee S; Kim TH; Ganeshan B
    Korean J Radiol; 2019 Apr; 20(4):558-568. PubMed ID: 30887738
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Impact of hybrid iterative reconstruction on unenhanced liver CT.
    Kondo M; Nishie A; Fujita N; Morita K; Shirasaka T; Arimura H; Nakamura Y; Honda H
    Br J Radiol; 2017 Feb; 90(1070):20150670. PubMed ID: 27993096
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Quantitative Features of Liver Lesions, Lung Nodules, and Renal Stones at Multi-Detector Row CT Examinations: Dependency on Radiation Dose and Reconstruction Algorithm.
    Solomon J; Mileto A; Nelson RC; Roy Choudhury K; Samei E
    Radiology; 2016 Apr; 279(1):185-94. PubMed ID: 26624973
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Chest CT with iterative reconstruction algorithms for airway stent evaluation in patients with malignant obstructive tracheobronchial diseases.
    Li T; Zhang Y; Wang Y; Gao J; Jiang Y
    Medicine (Baltimore); 2016 Sep; 95(39):e4873. PubMed ID: 27684818
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of iterative model, hybrid iterative, and filtered back projection reconstruction techniques in low-dose brain CT: impact of thin-slice imaging.
    Nakaura T; Iyama Y; Kidoh M; Yokoyama K; Oda S; Tokuyasu S; Harada K; Yamashita Y
    Neuroradiology; 2016 Mar; 58(3):245-51. PubMed ID: 26715558
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of Knowledge-based Iterative Model Reconstruction and Hybrid Reconstruction Techniques for Liver CT Evaluation of Hypervascular Hepatocellular Carcinoma.
    Park HJ; Lee JM; Park SB; Lee JB; Jeong YK; Yoon JH
    J Comput Assist Tomogr; 2016; 40(6):863-871. PubMed ID: 27331929
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Knowledge-based iterative model reconstruction (IMR) algorithm in ultralow-dose CT for evaluation of urolithiasis: evaluation of radiation dose reduction, image quality, and diagnostic performance.
    Park SB; Kim YS; Lee JB; Park HJ
    Abdom Imaging; 2015 Oct; 40(8):3137-46. PubMed ID: 26197735
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impact of Knowledge-Based Iterative Model Reconstruction in Abdominal Dynamic CT With Low Tube Voltage and Low Contrast Dose.
    Iyama Y; Nakaura T; Yokoyama K; Kidoh M; Harada K; Tokuyasu S; Yamashita Y
    AJR Am J Roentgenol; 2016 Apr; 206(4):687-93. PubMed ID: 26974470
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effect of iterative model reconstruction on coronary artery calcium quantification.
    Szilveszter B; Elzomor H; Károlyi M; Kolossváry M; Raaijmakers R; Benke K; Celeng C; Bartykowszki A; Bagyura Z; Lux Á; Merkely B; Maurovich-Horvat P
    Int J Cardiovasc Imaging; 2016 Jan; 32(1):153-60. PubMed ID: 26285899
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Knowledge-based iterative model reconstruction in coronary computed tomography angiography: comparison with hybrid iterative reconstruction and filtered back projection.
    Cha MJ; Seo JS; Yoo DS; Chong S
    Acta Radiol; 2018 Mar; 59(3):280-286. PubMed ID: 28648124
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Iterative model reconstruction reduces calcified plaque volume in coronary CT angiography.
    Károlyi M; Szilveszter B; Kolossváry M; Takx RA; Celeng C; Bartykowszki A; Jermendy ÁL; Panajotu A; Karády J; Raaijmakers R; Giepmans W; Merkely B; Maurovich-Horvat P
    Eur J Radiol; 2017 Feb; 87():83-89. PubMed ID: 28065380
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Feasibility of Iterative Model Reconstruction for Unenhanced Lumbar CT.
    Iyama Y; Nakaura T; Iyama A; Kidoh M; Katahira K; Oda S; Utsunomiya D; Yamashita Y
    Radiology; 2017 Jul; 284(1):153-160. PubMed ID: 28156203
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The Influence of Iterative Reconstruction on Coronary Artery Calcium Scoring-Phantom and Clinical Studies.
    Oda S; Utsunomiya D; Nakaura T; Funama Y; Yuki H; Kidoh M; Hirata K; Taguchi N; Honda K; Takaoka H; Iyama Y; Katahira K; Noda K; Oshima S; Tokuyasu S; Yamashita Y
    Acad Radiol; 2017 Mar; 24(3):295-301. PubMed ID: 27913107
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Noise Texture Deviation: A Measure for Quantifying Artifacts in Computed Tomography Images With Iterative Reconstructions.
    Morsbach F; Desbiolles L; Raupach R; Leschka S; Schmidt B; Alkadhi H
    Invest Radiol; 2017 Feb; 52(2):87-94. PubMed ID: 27548343
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Usefulness of a Low Tube Voltage: Knowledge-Based Iterative Model Reconstruction Algorithm for Computed Tomography Venography.
    Iyama Y; Nakaura T; Iyama A; Kidoh M; Oda S; Tokuyasu S; Yamashita Y
    J Comput Assist Tomogr; 2017; 41(5):811-816. PubMed ID: 28448403
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ultra-low dose abdominal MDCT: using a knowledge-based Iterative Model Reconstruction technique for substantial dose reduction in a prospective clinical study.
    Khawaja RDA; Singh S; Blake M; Harisinghani M; Choy G; Karosmangulu A; Padole A; Do S; Brown K; Thompson R; Morton T; Raihani N; Koehler T; Kalra MK
    Eur J Radiol; 2015 Jan; 84(1):2-10. PubMed ID: 25458225
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Screening for lung cancer using sub-millisievert chest CT with iterative reconstruction algorithm: image quality and nodule detectability.
    Zhang M; Qi W; Sun Y; Jiang Y; Liu X; Hong N
    Br J Radiol; 2018 Oct; 91(1090):20170658. PubMed ID: 29120665
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of an iterative model-based CT reconstruction algorithm by intra-patient comparison of standard and ultra-low-dose examinations.
    Noël PB; Engels S; Köhler T; Muenzel D; Franz D; Rasper M; Rummeny EJ; Dobritz M; Fingerle AA
    Acta Radiol; 2018 Oct; 59(10):1225-1231. PubMed ID: 29320863
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Low tube voltage intermediate tube current liver MDCT: sinogram-affirmed iterative reconstruction algorithm for detection of hypervascular hepatocellular carcinoma.
    Yu MH; Lee JM; Yoon JH; Baek JH; Han JK; Choi BI; Flohr TG
    AJR Am J Roentgenol; 2013 Jul; 201(1):23-32. PubMed ID: 23789655
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.