247 related articles for article (PubMed ID: 30466375)
1. Intraoperative Probe-Based Confocal Endomicroscopy to Histologically Differentiate Thyroid From Parathyroid Tissue Before Resection.
Ignat M; Lindner V; Vix M; Marescaux J; Mutter D
Surg Innov; 2019 Apr; 26(2):141-148. PubMed ID: 30466375
[TBL] [Abstract][Full Text] [Related]
2. Intraoperative confocal laser endomicroscopy for real-time in vivo tissue characterization during surgical procedures.
Fuks D; Pierangelo A; Validire P; Lefevre M; Benali A; Trebuchet G; Criton A; Gayet B
Surg Endosc; 2019 May; 33(5):1544-1552. PubMed ID: 30232616
[TBL] [Abstract][Full Text] [Related]
3. Intraoperative optical coherence tomography imaging to identify parathyroid glands.
Sommerey S; Al Arabi N; Ladurner R; Chiapponi C; Stepp H; Hallfeldt KK; Gallwas JK
Surg Endosc; 2015 Sep; 29(9):2698-704. PubMed ID: 25475518
[TBL] [Abstract][Full Text] [Related]
4. 99mTc-MIBI radio-guided minimally invasive parathyroidectomy: experience with patients with normal thyroids and nodular goiters.
Casara D; Rubello D; Cauzzo C; Pelizzo MR
Thyroid; 2002 Jan; 12(1):53-61. PubMed ID: 11838731
[TBL] [Abstract][Full Text] [Related]
5. Utility of birefringent crystal identification by polarized light microscopy in distinguishing thyroid from parathyroid tissue on intraoperative frozen sections.
Wong KS; Lewis JS; Gottipati S; Chernock RD
Am J Surg Pathol; 2014 Sep; 38(9):1212-9. PubMed ID: 24618617
[TBL] [Abstract][Full Text] [Related]
6. Diagnostic accuracy of probe-based confocal laser endomicroscopy in detecting residual colorectal neoplasia after EMR: a prospective study.
Shahid MW; Buchner AM; Coron E; Woodward TA; Raimondo M; Dekker E; Fockens P; Wallace MB
Gastrointest Endosc; 2012 Mar; 75(3):525-33. PubMed ID: 22051243
[TBL] [Abstract][Full Text] [Related]
7. Probe-Based Confocal Laser Endomicroscopy During Transurethral Resection of Bladder Tumors Improves the Diagnostic Accuracy and Therapeutic Efficacy.
Lee J; Jeh SU; Koh DH; Chung DY; Kim MS; Goh HJ; Lee JY; Choi YD
Ann Surg Oncol; 2019 Apr; 26(4):1158-1165. PubMed ID: 30719635
[TBL] [Abstract][Full Text] [Related]
8. Intraoperative use of optical coherence tomography to differentiate normal and diseased thyroid and parathyroid tissues from lymph node and fat.
Rubinstein M; Hu AC; Chung PS; Kim JH; Osann KE; Schalch P; Armstrong WB; Wong BJF
Lasers Med Sci; 2021 Mar; 36(2):269-278. PubMed ID: 32337680
[TBL] [Abstract][Full Text] [Related]
9. Intraoperative near-infrared autofluorescence imaging of parathyroid glands.
Ladurner R; Sommerey S; Arabi NA; Hallfeldt KKJ; Stepp H; Gallwas JKS
Surg Endosc; 2017 Aug; 31(8):3140-3145. PubMed ID: 27844237
[TBL] [Abstract][Full Text] [Related]
10. Prospective Trial on Probe-Based Confocal Laser Endomicroscopy for the Identification of the Distal Limit in Rectal Adenocarcinoma.
Wijsmuller AR; Ghnassia JP; Varatharajah S; Schaeffer M; Leroy J; Marescaux J; Ignat M; Mutter D
Surg Innov; 2018 Aug; 25(4):313-322. PubMed ID: 29732957
[TBL] [Abstract][Full Text] [Related]
11. The utility of indocyanine green near infrared fluorescent imaging in the identification of parathyroid glands during surgery for primary hyperparathyroidism.
Zaidi N; Bucak E; Okoh A; Yazici P; Yigitbas H; Berber E
J Surg Oncol; 2016 Jun; 113(7):771-4. PubMed ID: 27039880
[TBL] [Abstract][Full Text] [Related]
12. Intraoperative Parathyroid Autofluorescence Detection in Patients with Primary Hyperparathyroidism.
Squires MH; Jarvis R; Shirley LA; Phay JE
Ann Surg Oncol; 2019 Apr; 26(4):1142-1148. PubMed ID: 30675703
[TBL] [Abstract][Full Text] [Related]
13. Clinical role of 99mTcO4/MIBI scan, ultrasound and intra-operative gamma probe in the performance of unilateral and minimally invasive surgery in primary hyperparathyroidism.
Casara D; Rubello D; Pelizzo MR; Shapiro B
Eur J Nucl Med; 2001 Sep; 28(9):1351-9. PubMed ID: 11585294
[TBL] [Abstract][Full Text] [Related]
14. Autofluorescence imaging of parathyroid glands: An assessment of potential indications.
Kose E; Rudin AV; Kahramangil B; Moore E; Aydin H; Donmez M; Krishnamurthy V; Siperstein A; Berber E
Surgery; 2020 Jan; 167(1):173-179. PubMed ID: 31526579
[TBL] [Abstract][Full Text] [Related]
15. Intraoperative Probe-Based Confocal Laser Endomicroscopy in Surgery and Stereotactic Biopsy of Low-Grade and High-Grade Gliomas: A Feasibility Study in Humans.
Pavlov V; Meyronet D; Meyer-Bisch V; Armoiry X; Pikul B; Dumot C; Beuriat PA; Signorelli F; Guyotat J
Neurosurgery; 2016 Oct; 79(4):604-12. PubMed ID: 27643918
[TBL] [Abstract][Full Text] [Related]
16. Importance of radio-guided minimally invasive parathyroidectomy using hand-held gamma probe and low (99m)Tc-MIBI dose. Technical considerations and long-term clinical results.
Rubello D; Casara D; Giannini S; Piotto A; De Carlo E; Muzzio PC; Pelizzo MR
Q J Nucl Med; 2003 Jun; 47(2):129-38. PubMed ID: 12865873
[TBL] [Abstract][Full Text] [Related]
17. Intraoperative Identification of the Parathyroid Gland with a Fluorescence Detection System.
Shinden Y; Nakajo A; Arima H; Tanoue K; Hirata M; Kijima Y; Maemura K; Natsugoe S
World J Surg; 2017 Jun; 41(6):1506-1512. PubMed ID: 28168320
[TBL] [Abstract][Full Text] [Related]
18. Use of methylene blue and near-infrared fluorescence in thyroid and parathyroid surgery.
Hillary SL; Guillermet S; Brown NJ; Balasubramanian SP
Langenbecks Arch Surg; 2018 Feb; 403(1):111-118. PubMed ID: 29230539
[TBL] [Abstract][Full Text] [Related]
19. Diagnostic accuracy of probe-based confocal laser endomicroscopy and narrow band imaging in detection of dysplasia in duodenal polyps.
Shahid MW; Buchner A; Gomez V; Krishna M; Woodward TA; Raimondo M; Wallace MB
J Clin Gastroenterol; 2012; 46(5):382-9. PubMed ID: 22499072
[TBL] [Abstract][Full Text] [Related]
20. Cutting Edge in Thyroid Surgery: Autofluorescence of Parathyroid Glands.
Falco J; Dip F; Quadri P; de la Fuente M; Rosenthal R
J Am Coll Surg; 2016 Aug; 223(2):374-80. PubMed ID: 27212004
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]