BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

198 related articles for article (PubMed ID: 30467339)

  • 21. Mechanosensitivity of ion channels based on protein-lipid interactions.
    Yoshimura K; Sokabe M
    J R Soc Interface; 2010 Jun; 7 Suppl 3(Suppl 3):S307-20. PubMed ID: 20356872
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Membrane tension, lipid adaptation, conformational changes, and energetics in MscL gating.
    Rui H; Kumar R; Im W
    Biophys J; 2011 Aug; 101(3):671-9. PubMed ID: 21806935
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Mechanosensitive channel MscL induces non-apoptotic cell death and its suppression of tumor growth by ultrasound.
    Wen X; Wang Y; Zhu Z; Guo S; Qian J; Zhu J; Yang Z; Qiu W; Li G; Huang L; Jiang M; Tan L; Zheng H; Shu Q; Li Y
    Front Chem; 2023; 11():1130563. PubMed ID: 36936526
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Hydration properties of mechanosensitive channel pores define the energetics of gating.
    Anishkin A; Akitake B; Kamaraju K; Chiang CS; Sukharev S
    J Phys Condens Matter; 2010 Nov; 22(45):454120. PubMed ID: 21339607
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Conformational changes involved in MscL channel gating measured using FRET spectroscopy.
    Corry B; Rigby P; Liu ZW; Martinac B
    Biophys J; 2005 Dec; 89(6):L49-51. PubMed ID: 16199508
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Focused ultrasound activates voltage-gated calcium channels through depolarizing TRPC1 sodium currents in kidney and skeletal muscle.
    Burks SR; Lorsung RM; Nagle ME; Tu TW; Frank JA
    Theranostics; 2019; 9(19):5517-5531. PubMed ID: 31534500
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Structure-based membrane dome mechanism for Piezo mechanosensitivity.
    Guo YR; MacKinnon R
    Elife; 2017 Dec; 6():. PubMed ID: 29231809
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Gating-by-tilt of mechanically sensitive membrane channels.
    Turner MS; Sens P
    Phys Rev Lett; 2004 Sep; 93(11):118103. PubMed ID: 15447384
    [TBL] [Abstract][Full Text] [Related]  

  • 29. On the role of individual subunits in MscL gating: "all for one, one for all?".
    Mika JT; Birkner JP; Poolman B; Koçer A
    FASEB J; 2013 Mar; 27(3):882-92. PubMed ID: 23193173
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Membrane stiffness is one of the key determinants of E. coli MscS channel mechanosensitivity.
    Xue F; Cox CD; Bavi N; Rohde PR; Nakayama Y; Martinac B
    Biochim Biophys Acta Biomembr; 2020 May; 1862(5):183203. PubMed ID: 31981589
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Gating of MscL studied by steered molecular dynamics.
    Gullingsrud J; Schulten K
    Biophys J; 2003 Oct; 85(4):2087-99. PubMed ID: 14507677
    [TBL] [Abstract][Full Text] [Related]  

  • 32. "Force-from-lipids" gating of mechanosensitive channels modulated by PUFAs.
    Ridone P; Grage SL; Patkunarajah A; Battle AR; Ulrich AS; Martinac B
    J Mech Behav Biomed Mater; 2018 Mar; 79():158-167. PubMed ID: 29304430
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Sensing and responding to membrane tension: the bacterial MscL channel as a model system.
    Iscla I; Blount P
    Biophys J; 2012 Jul; 103(2):169-74. PubMed ID: 22853893
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Phosphatidylinositol is crucial for the mechanosensitivity of Mycobacterium tuberculosis MscL.
    Zhong D; Blount P
    Biochemistry; 2013 Aug; 52(32):5415-20. PubMed ID: 23875651
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Membrane-protein interactions in mechanosensitive channels.
    Wiggins P; Phillips R
    Biophys J; 2005 Feb; 88(2):880-902. PubMed ID: 15542561
    [TBL] [Abstract][Full Text] [Related]  

  • 36. In vitro synthesis and oligomerization of the mechanosensitive channel of large conductance, MscL, into a functional ion channel.
    Price CE; Kocer A; Kol S; van der Berg JP; Driessen AJ
    FEBS Lett; 2011 Jan; 585(1):249-54. PubMed ID: 21134371
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Piezo1 Channels Are Inherently Mechanosensitive.
    Syeda R; Florendo MN; Cox CD; Kefauver JM; Santos JS; Martinac B; Patapoutian A
    Cell Rep; 2016 Nov; 17(7):1739-1746. PubMed ID: 27829145
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Hydrophobic gating of mechanosensitive channel of large conductance evidenced by single-subunit resolution.
    Birkner JP; Poolman B; Koçer A
    Proc Natl Acad Sci U S A; 2012 Aug; 109(32):12944-9. PubMed ID: 22826215
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The gating mechanism of the bacterial mechanosensitive channel MscL revealed by molecular dynamics simulations: from tension sensing to channel opening.
    Sawada Y; Murase M; Sokabe M
    Channels (Austin); 2012; 6(4):317-31. PubMed ID: 23146938
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Collective response of self-organized clusters of mechanosensitive channels.
    Guseva K; Thiel M; Booth I; Miller S; Grebogi C; de Moura A
    Phys Rev E Stat Nonlin Soft Matter Phys; 2011 Feb; 83(2 Pt 1):020901. PubMed ID: 21405810
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.