These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

238 related articles for article (PubMed ID: 30470238)

  • 41. Powered exoskeletons for bipedal locomotion after spinal cord injury.
    Contreras-Vidal JL; A Bhagat N; Brantley J; Cruz-Garza JG; He Y; Manley Q; Nakagome S; Nathan K; Tan SH; Zhu F; Pons JL
    J Neural Eng; 2016 Jun; 13(3):031001. PubMed ID: 27064508
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Voluntary driven exoskeleton as a new tool for rehabilitation in chronic spinal cord injury: a pilot study.
    Aach M; Cruciger O; Sczesny-Kaiser M; Höffken O; Meindl RCh; Tegenthoff M; Schwenkreis P; Sankai Y; Schildhauer TA
    Spine J; 2014 Dec; 14(12):2847-53. PubMed ID: 24704677
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Incidental bilateral calcaneal fractures following overground walking with a wearable robotic exoskeleton in a wheelchair user with a chronic spinal cord injury: is zero risk possible?
    Bass A; Morin SN; Vermette M; Aubertin-Leheudre M; Gagnon DH
    Osteoporos Int; 2020 May; 31(5):1007-1011. PubMed ID: 31932962
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Device-Training for Individuals with Thoracic and Lumbar Spinal Cord Injury Using a Powered Exoskeleton for Technically Assisted Mobility: Achievements and User Satisfaction.
    Platz T; Gillner A; Borgwaldt N; Kroll S; Roschka S
    Biomed Res Int; 2016; 2016():8459018. PubMed ID: 27610382
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Predictors of exoskeleton motor learning in spinal cord injured patients.
    van Dijsseldonk RB; Rijken H; van Nes IJW; van de Meent H; Keijsers NLW
    Disabil Rehabil; 2021 Jul; 43(14):1982-1988. PubMed ID: 31724882
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Results of the first interim analysis of the RAPPER II trial in patients with spinal cord injury: ambulation and functional exercise programs in the REX powered walking aid.
    Birch N; Graham J; Priestley T; Heywood C; Sakel M; Gall A; Nunn A; Signal N
    J Neuroeng Rehabil; 2017 Jun; 14(1):60. PubMed ID: 28629390
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Robotic exoskeletons for reengaging in everyday activities: promises, pitfalls, and opportunities.
    Fritz H; Patzer D; Galen SS
    Disabil Rehabil; 2019 Mar; 41(5):560-563. PubMed ID: 29110547
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Feedback-Error Learning for time-effective gait trajectory tracking in wearable exoskeletons.
    Figueiredo J; Fernandes PN; Moreno JC; Santos CP
    Anat Rec (Hoboken); 2023 Apr; 306(4):728-740. PubMed ID: 35869906
    [TBL] [Abstract][Full Text] [Related]  

  • 49. An integrated gait rehabilitation training based on Functional Electrical Stimulation cycling and overground robotic exoskeleton in complete spinal cord injury patients: Preliminary results.
    Mazzoleni S; Battini E; Rustici A; Stampacchia G
    IEEE Int Conf Rehabil Robot; 2017 Jul; 2017():289-293. PubMed ID: 28813833
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Impact of locomotion training with a neurologic controlled hybrid assistive limb (HAL) exoskeleton on neuropathic pain and health related quality of life (HRQoL) in chronic SCI: a case study (.).
    Cruciger O; Schildhauer TA; Meindl RC; Tegenthoff M; Schwenkreis P; Citak M; Aach M
    Disabil Rehabil Assist Technol; 2016 Aug; 11(6):529-34. PubMed ID: 25382234
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Fully Wearable Actuated Soft Exoskeleton for Grasping Assistance in Everyday Activities.
    Bützer T; Lambercy O; Arata J; Gassert R
    Soft Robot; 2021 Apr; 8(2):128-143. PubMed ID: 32552422
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Voluntary control of wearable robotic exoskeletons by patients with paresis via neuromechanical modeling.
    Durandau G; Farina D; Asín-Prieto G; Dimbwadyo-Terrer I; Lerma-Lara S; Pons JL; Moreno JC; Sartori M
    J Neuroeng Rehabil; 2019 Jul; 16(1):91. PubMed ID: 31315633
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Appraisals of robotic locomotor exoskeletons for gait: focus group insights from potential users with spinal cord injuries.
    Heinemann AW; Kinnett-Hopkins D; Mummidisetty CK; Bond RA; Ehrlich-Jones L; Furbish C; Field-Fote E; Jayaraman A
    Disabil Rehabil Assist Technol; 2020 Oct; 15(7):762-772. PubMed ID: 32255369
    [No Abstract]   [Full Text] [Related]  

  • 54. Mobility Outcomes Following Five Training Sessions with a Powered Exoskeleton.
    Hartigan C; Kandilakis C; Dalley S; Clausen M; Wilson E; Morrison S; Etheridge S; Farris R
    Top Spinal Cord Inj Rehabil; 2015; 21(2):93-9. PubMed ID: 26364278
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Gait training after spinal cord injury: safety, feasibility and gait function following 8 weeks of training with the exoskeletons from Ekso Bionics.
    Bach Baunsgaard C; Vig Nissen U; Katrin Brust A; Frotzler A; Ribeill C; Kalke YB; León N; Gómez B; Samuelsson K; Antepohl W; Holmström U; Marklund N; Glott T; Opheim A; Benito J; Murillo N; Nachtegaal J; Faber W; Biering-Sørensen F
    Spinal Cord; 2018 Feb; 56(2):106-116. PubMed ID: 29105657
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Exoskeleton Training May Improve Level of Physical Activity After Spinal Cord Injury: A Case Series.
    Gorgey AS; Wade R; Sumrell R; Villadelgado L; Khalil RE; Lavis T
    Top Spinal Cord Inj Rehabil; 2017; 23(3):245-255. PubMed ID: 29339900
    [No Abstract]   [Full Text] [Related]  

  • 57. Investigating User Volitional Influence on Step Length in Powered Exoskeleton Designed for Users with SCI.
    Cheng X; Fong J; Tan Y; Oetomo D
    IEEE Int Conf Rehabil Robot; 2022 Jul; 2022():1-6. PubMed ID: 36176164
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Walking with a powered robotic exoskeleton: Subjective experience, spasticity and pain in spinal cord injured persons.
    Stampacchia G; Rustici A; Bigazzi S; Gerini A; Tombini T; Mazzoleni S
    NeuroRehabilitation; 2016 Jun; 39(2):277-83. PubMed ID: 27372363
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Characterization of surface electromyography patterns of healthy and incomplete spinal cord injury subjects interacting with an upper-extremity exoskeleton.
    McDonald CG; Dennis TA; O'Malley MK
    IEEE Int Conf Rehabil Robot; 2017 Jul; 2017():164-169. PubMed ID: 28813812
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Overground walking with a robotic exoskeleton elicits trunk muscle activity in people with high-thoracic motor-complete spinal cord injury.
    Alamro RA; Chisholm AE; Williams AMM; Carpenter MG; Lam T
    J Neuroeng Rehabil; 2018 Nov; 15(1):109. PubMed ID: 30458839
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.