BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

166 related articles for article (PubMed ID: 30473066)

  • 1. Direct quantification of EGFR variant allele frequency in cell-free DNA using a microfluidic-free digital droplet PCR assay.
    Demaree B; Weisgerber D; Dolatmoradi A; Hatori M; Abate AR
    Methods Cell Biol; 2018; 148():119-131. PubMed ID: 30473066
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Denaturation-Enhanced Droplet Digital PCR for Liquid Biopsies.
    Fitarelli-Kiehl M; Yu F; Ashtaputre R; Leong KW; Ladas I; Supplee J; Paweletz C; Mitra D; Schoenfeld JD; Parangi S; Makrigiorgos GM
    Clin Chem; 2018 Dec; 64(12):1762-1771. PubMed ID: 30274976
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Detection of EGFR mutations in non-small cell lung cancer by droplet digital PCR.
    Williamson DFK; Marris SRN; Rojas-Rudilla V; Bruce JL; Paweletz CP; Oxnard GR; Sholl LM; Dong F
    PLoS One; 2022; 17(2):e0264201. PubMed ID: 35202431
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Multiple Hotspot Mutations Scanning by Single Droplet Digital PCR.
    Decraene C; Silveira AB; Bidard FC; Vallée A; Michel M; Melaabi S; Vincent-Salomon A; Saliou A; Houy A; Milder M; Lantz O; Ychou M; Denis MG; Pierga JY; Stern MH; Proudhon C
    Clin Chem; 2018 Feb; 64(2):317-328. PubMed ID: 29122835
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Optimal method for quantitative detection of plasma EGFR T790M mutation using droplet digital PCR system.
    Suzawa K; Yamamoto H; Ohashi K; Hashida S; Tomida S; Kubo T; Maki Y; Soh J; Tsukuda K; Kiura K; Miyoshi S; Toyooka S
    Oncol Rep; 2017 May; 37(5):3100-3106. PubMed ID: 28405680
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Applying Standard Clinical Chemistry Assay Validation to Droplet Digital PCR Quantitative Liquid Biopsy Testing.
    Milosevic D; Mills JR; Campion MB; Vidal-Folch N; Voss JS; Halling KC; Highsmith WE; Liu MC; Kipp BR; Grebe SKG
    Clin Chem; 2018 Dec; 64(12):1732-1742. PubMed ID: 30237149
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An improved digital polymerase chain reaction protocol to capture low-copy KRAS mutations in plasma cell-free DNA by resolving 'subsampling' issues.
    Ono Y; Sugitani A; Karasaki H; Ogata M; Nozaki R; Sasajima J; Yokochi T; Asahara S; Koizumi K; Ando K; Hironaka K; Daito T; Mizukami Y
    Mol Oncol; 2017 Oct; 11(10):1448-1458. PubMed ID: 28691390
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Clinical value of droplet digital polymerase chain reaction method in detecting plasma circulating tumor deoxyribonucleic acid epidermal growth factor receptor mutations in advanced pulmonary adenocarcinoma patients].
    Ma L; Lü JL; Li K; Wang JH; Yang XJ; Li X; Zhang H; Zhang Q; Qin N; Zhang SC
    Zhonghua Yi Xue Za Zhi; 2018 Aug; 98(29):2336-2340. PubMed ID: 30107692
    [No Abstract]   [Full Text] [Related]  

  • 9. Monitoring of Response and Resistance in Plasma of EGFR-Mutant Lung Cancer Using Droplet Digital PCR.
    Kuang Y; O'Connell A; Sacher AG; Feeney N; Alden RS; Oxnard GR; Paweletz CP
    Methods Mol Biol; 2018; 1768():193-207. PubMed ID: 29717445
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Simple Polydisperse Droplet Emulsion Polymerase Chain Reaction with Statistical Volumetric Correction Compared with Microfluidic Droplet Digital Polymerase Chain Reaction.
    Byrnes SA; Chang TC; Huynh T; Astashkina A; Weigl BH; Nichols KP
    Anal Chem; 2018 Aug; 90(15):9374-9380. PubMed ID: 29985594
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Quantification of plasma EGFR mutations in patients with lung cancers: Comparison of the performance of ARMS-Plus and droplet digital PCR.
    Wang L; Guo Q; Yu W; Qiao L; Zhao M; Zhang C; Hu X; Yang G; Xiong L; Lou J
    Lung Cancer; 2017 Dec; 114():31-37. PubMed ID: 29173762
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Detection of epidermal growth factor receptor gene mutations in different types of non-small cell lung cancer by droplet digital PCR and amplification refractory mutation system].
    Li R; Ye SB; He Y; Wang X; Wu N; Xia QY; Shen Q; Shi SS
    Zhonghua Bing Li Xue Za Zhi; 2017 Nov; 46(11):764-768. PubMed ID: 29136689
    [No Abstract]   [Full Text] [Related]  

  • 13. Accurate quantitation of circulating cell-free mitochondrial DNA in plasma by droplet digital PCR.
    Ye W; Tang X; Liu C; Wen C; Li W; Lyu J
    Anal Bioanal Chem; 2017 Apr; 409(10):2727-2735. PubMed ID: 28154880
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Droplet digital PCR improved the EGFR mutation diagnosis with pleural fluid samples in non-small-cell lung cancer patients.
    Li X; Liu Y; Shi W; Xu H; Hu H; Dong Z; Zhu G; Sun Y; Liu B; Gao H; Tang C; Liu X
    Clin Chim Acta; 2017 Aug; 471():177-184. PubMed ID: 28602964
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Multiplex picoliter-droplet digital PCR for quantitative assessment of EGFR mutations in circulating cell-free DNA derived from advanced non-small cell lung cancer patients.
    Yu Q; Huang F; Zhang M; Ji H; Wu S; Zhao Y; Zhang C; Wu J; Wang B; Pan B; Zhang X; Guo W
    Mol Med Rep; 2017 Aug; 16(2):1157-1166. PubMed ID: 29067441
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Prospective Validation of Rapid Plasma Genotyping for the Detection of EGFR and KRAS Mutations in Advanced Lung Cancer.
    Sacher AG; Paweletz C; Dahlberg SE; Alden RS; O'Connell A; Feeney N; Mach SL; Jänne PA; Oxnard GR
    JAMA Oncol; 2016 Aug; 2(8):1014-22. PubMed ID: 27055085
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Rare Variant Quantitation Using Droplet Digital PCR.
    Parkin B
    Methods Mol Biol; 2019; 1881():239-251. PubMed ID: 30350210
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Highly Sensitive and Reliable Detection of EGFR Exon 19 Deletions by Droplet Digital Polymerase Chain Reaction.
    Oskina N; Oscorbin I; Khrapov E; Boyarskikh U; Subbotin D; Demidova I; Imyanitov E; Filipenko M
    Mol Diagn Ther; 2017 Oct; 21(5):555-562. PubMed ID: 28589341
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Plasma epidermal growth factor receptor mutation testing with a chip-based digital PCR system in patients with advanced non-small cell lung cancer.
    Kasahara N; Kenmotsu H; Serizawa M; Umehara R; Ono A; Hisamatsu Y; Wakuda K; Omori S; Nakashima K; Taira T; Naito T; Murakami H; Koh Y; Mori K; Endo M; Nakajima T; Yamada M; Kusuhara M; Takahashi T
    Lung Cancer; 2017 Apr; 106():138-144. PubMed ID: 28285688
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Absolute quantification of lung cancer related microRNA by droplet digital PCR.
    Wang P; Jing F; Li G; Wu Z; Cheng Z; Zhang J; Zhang H; Jia C; Jin Q; Mao H; Zhao J
    Biosens Bioelectron; 2015 Dec; 74():836-42. PubMed ID: 26232679
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.