These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

159 related articles for article (PubMed ID: 30474184)

  • 21. Development and validation of a risk scoring system based on baseline angiographic results by visual estimation for risk prEdiction of side-branch OccLusion in coronary bifurcation InterVEntion: The baseline V-RESOLVE score.
    He Y; Zhang D; Yin D; Zhu C; Feng L; Song C; Chen C; Feng L; Dou K
    Catheter Cardiovasc Interv; 2019 Feb; 93(S1):810-817. PubMed ID: 30690861
    [TBL] [Abstract][Full Text] [Related]  

  • 22. New insight to estimate under-expansion after stent implantation on bifurcation lesions using optical coherence tomography.
    Nakamura D; Attizzani GF; Nishino S; Tanaka K; Soud M; Pereira GT; Leygerman M; Fares A; Schnell A; Costa MA; Erglis A; Bezerra HG
    Int J Cardiovasc Imaging; 2017 Nov; 33(11):1677-1684. PubMed ID: 28597125
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Multimodality imaging of attenuated plaque using grayscale and virtual histology intravascular ultrasound and optical coherent tomography.
    Kang SJ; Ahn JM; Han S; Park DW; Lee SW; Kim YH; Lee CW; Park SW; Mintz GS; Park SJ
    Catheter Cardiovasc Interv; 2016 Jul; 88(1):E1-E11. PubMed ID: 25511369
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Impact of guidewire recrossing point into stent jailed side branch for optimal kissing balloon dilatation: core lab 3D optical coherence tomography analysis.
    Okamura T; Nagoshi R; Fujimura T; Murasato Y; Yamawaki M; Ono S; Serikawa T; Hikichi Y; Norita H; Nakao F; Sakamoto T; Shinke T; Shite J
    EuroIntervention; 2018 Feb; 13(15):e1785-e1793. PubMed ID: 29131806
    [TBL] [Abstract][Full Text] [Related]  

  • 25. In-stent fractional flow reserve variations and related optical coherence tomography findings: the FFR-OCT co-registration study.
    Pyxaras SA; Adriaenssens T; Barbato E; Ughi GJ; Di Serafino L; De Vroey F; Toth G; Tu S; Reiber JHC; Bax JJ; Wijns W
    Int J Cardiovasc Imaging; 2018 Apr; 34(4):495-502. PubMed ID: 29080150
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Optical coherence tomography for guiding wire into a side branch coronary artery with flush total occlusion.
    Qureshi YH; Weisz G; Maehara A; Hakim DA; Fall K; Castaneda A; Moses JW
    Cardiovasc Revasc Med; 2015; 16(1):55-7. PubMed ID: 25081229
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Plaque Morphology Predictors of Side Branch Occlusion After Main Vessel Stenting in Coronary Bifurcation Lesions: Optical Coherence Tomography Imaging Study.
    Kini AS; Yoshimura T; Vengrenyuk Y; Amirian J; Hasan C; Baber U; Narula J; Sharma SK
    JACC Cardiovasc Interv; 2016 Apr; 9(8):862-865. PubMed ID: 27101914
    [No Abstract]   [Full Text] [Related]  

  • 28. Neointimal response to everolimus-eluting bioresorbable scaffolds implanted at bifurcating coronary segments: insights from optical coherence tomography.
    Sato T; Jose J; El-Mawardy M; Sulimov DS; Tölg R; Richardt G; Abdel-Wahab M
    Int J Cardiovasc Imaging; 2017 Feb; 33(2):169-175. PubMed ID: 27757563
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Feasibility and usefulness of three-dimensional optical coherence tomography guidance for optimal side branch treatment in coronary bifurcation stenting.
    Nagoshi R; Okamura T; Murasato Y; Fujimura T; Yamawaki M; Ono S; Serikawa T; Hikichi Y; Nakao F; Sakamoto T; Shinke T; Kijima Y; Kozuki A; Shibata H; Shite J
    Int J Cardiol; 2018 Jan; 250():270-274. PubMed ID: 29030141
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Practical Usefulness of Dual Lumen Catheter-Facilitated Reverse Wire Technique for Markedly Angulated Bifurcated Lesions.
    Nomura T; Higuchi Y; Kubota H; Miyawaki D; Urata R; Sugimoto T; Kato T; Keira N; Tatsumi T
    J Interv Cardiol; 2015 Dec; 28(6):544-50. PubMed ID: 26643002
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Tips of the dual-lumen microcatheter-facilitated reverse wire technique in percutaneous coronary interventions for markedly angulated bifurcated lesions.
    Nomura T; Kikai M; Hori Y; Yoshioka K; Kubota H; Miyawaki D; Urata R; Sugimoto T; Keira N; Tatsumi T
    Cardiovasc Interv Ther; 2018 Apr; 33(2):146-153. PubMed ID: 28190187
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Impact of lesion angle on optical coherence tomography findings and clinical outcomes after drug-eluting stent implantation in curved vessels.
    Nakamura S; Kimura S; Nakagama S; Misawa T; Mizusawa M; Hayasaka K; Yamakami Y; Kojima K; Sagawa Y; Hishikari K; Hikita H; Takahashi A; Hirao K
    Int J Cardiovasc Imaging; 2019 Dec; 35(12):2147-2155. PubMed ID: 31359232
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Impact of branching angle on neointimal coverage of drug-eluting stents implanted in bifurcation lesions.
    Watanabe M; Uemura S; Kita Y; Sugawara Y; Goryo Y; Ueda T; Soeda T; Okayama S; Okura H; Kume T; Saito Y
    Coron Artery Dis; 2016 Dec; 27(8):682-689. PubMed ID: 27525716
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Procedural findings and early healing response after implantation of a self-apposing bioresorbable scaffold in coronary bifurcation lesions.
    Holck EN; Fox-Maule C; Barkholt TØ; Jakobsen L; Tu S; Maeng M; Dijkstra J; Christiansen EH; Holm NR
    Int J Cardiovasc Imaging; 2019 Jul; 35(7):1199-1210. PubMed ID: 31053981
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Angiography alone versus angiography plus optical coherence tomography to guide decision-making during percutaneous coronary intervention: the Centro per la Lotta contro l'Infarto-Optimisation of Percutaneous Coronary Intervention (CLI-OPCI) study.
    Prati F; Di Vito L; Biondi-Zoccai G; Occhipinti M; La Manna A; Tamburino C; Burzotta F; Trani C; Porto I; Ramazzotti V; Imola F; Manzoli A; Materia L; Cremonesi A; Albertucci M
    EuroIntervention; 2012 Nov; 8(7):823-9. PubMed ID: 23034247
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Optical Coherence Tomography-Guided Percutaneous Coronary Intervention With Low-Molecular-Weight Dextran - Effect on Renal Function.
    Kurogi K; Ishii M; Sakamoto K; Komaki S; Kusaka H; Yamamoto N; Takashio S; Arima Y; Yamamoto E; Kaikita K; Tsujita K
    Circ J; 2020 May; 84(6):917-925. PubMed ID: 32350234
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Long-term invasive follow-up of bioresorbable vascular scaffold: Optical Coherence Tomography assessment of jailed side branches.
    Paradies V; Smits PC; Vachojannis GJ; Royaards KJ; Wassing J; van der Ent M
    Cardiovasc Revasc Med; 2018 Apr; 19(3 Pt A):279-285. PubMed ID: 29066339
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Structural Damage of Jailed Guidewire During the Treatment of Coronary Bifurcation Lesions: A Microscopic Randomized Trial.
    Pan M; Ojeda S; Villanueva E; Chavarria J; Romero M; Suarez de Lezo J; Mazuelos F; Segura J; Carrasco F; Hidalgo F; Lopez Aguilera J; Rodriguez S; Puente M; Suarez de Lezo J
    JACC Cardiovasc Interv; 2016 Sep; 9(18):1917-24. PubMed ID: 27659568
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A simplified reverse wire technique using an angulated supercross microcatheter.
    Chan YH; Cheng VYH; Wong CW; Lam CS
    Catheter Cardiovasc Interv; 2020 Jul; 96(1):E93-E97. PubMed ID: 31441574
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Impact of Plaque Rupture Detected by Optical Coherence Tomography on Transmural Extent of Infarction After Successful Stenting in ST-Segment Elevation Acute Myocardial Infarction.
    Satogami K; Ino Y; Kubo T; Tanimoto T; Orii M; Matsuo Y; Ota S; Yamaguchi T; Shiono Y; Shimamura K; Katayama Y; Aoki H; Nishiguchi T; Ozaki Y; Yamano T; Kameyama T; Kuroi A; Kitabata H; Tanaka A; Hozumi T; Akasaka T
    JACC Cardiovasc Interv; 2017 May; 10(10):1025-1033. PubMed ID: 28456697
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.